PXS24E-e10/F-IT PXS24E10A001 EATON ELECTRIC Electronic overcurrent protection for 24V DC, fix 10A with suppl.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PXS24E-e10/F-IT PXS24E10A001 EATON ELECTRIC Electronic overcurrent protection for 24V DC, fix 10A with suppl..

PXS24E-e10/F-IT

PXS24E10A001

EATON-MOELLER

Electronic overcurrent protection for 24V DC, fix 10A with supply terminals

Protec. Electronic overcurrent for 24V DC, fixed 10A + terminals

PXS24E-e10/F-IT - Electronic overcurrent protection for 24V DC, fix 10A with supply terminals

More details


Relays > Current monitoring relay

Electronic overcurrent protection

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Electronic overcurrent protection for 24V DC, fix 10A with supply terminals
Reliable modular elektronic overcurrent protection for 24V DC systems, simple busbar solution, fixed or variable amperages, optionally with control input and tripped message output, plug-in terminals (+ 24V and 0V) for up to 3 loads, robust design, local and (optional) remote-controllable

Delivery program

Basic function
Automation engineering 24V
Number of channels
1
Protection
Electronic
Rated current [In]
10 A
Rated operating voltage [Un]
24 V
Standard/Approval
CE
UL508

Technical data

Electrical
Operational voltage [UB]
24V DC (15 .. 30V DC)
Rated operational current fix [IN]
10 A
Overload current and short-circuit current trip
Type 1.3 x INwith active current limitation
Trip time for electronic trip
90 ms
Capacitive loads
Up to 20,000 µF
Inductive loads
Up to 13 A
Mechanical
Width
17.5 mm
Depth
119.2 mm
TerminalsInput terminals
3x LINE (+) and 3x GND (-)
TerminalsOutput Terminals
3x LOAD (+) and 3x GND (-)
TerminalsTerminal type:
Push in terminals
TerminalsTerminal capacity
2.5 (flexible with ferrules)
4 (rigid) mm²
Busbars
LINE (+) and GND (-); max 60A in various lengths of up to 1m
Mounting
snap-fit on mounting rail TH35 (EN 60715)
Status LED
Two-colored
Green = OK; Red = Triggered
OFF = Channel not in operation
Slide switch
On/Off/Reset
Text field
17,5 x 6 mm
Degree of Protection
IP20
Ambient temperature
-30 - +55 °C
Permissible storage and transport temperatures
-40 - +100 °C
Base dimension
92.5 mm

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
10 A
Equipment heat dissipation, current-dependent [Pvid]
1.6 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Relays (EG000019) / Current monitoring relay (EC001440)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Monitoring equipment (low-voltage switch technology) / Current monitoring equipment ([email protected] [AKF096014])
Type of electric connection
Plug-in connection
With detachable clamps
No
Single-phase under current possible
No
Three-phase under current possible
No
Single-phase over current possible
No
Three-phase over current possible
No
Single-phase hysteresis possible
No
Three-phase hysteresis possible
No
Contains function DC-voltage under current
No
Contains function DC-voltage over current
Yes
Function DC-current hysteresis
No
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
16 - 30 V
Voltage type for actuating
DC
Current measurement range
0 - 13 A
Min. adjustable delay-on energization time
0 s
Max. permitted delay-on energization time
0 s
Min. adjustable off-delay time
0 s
Max. permitted off-delay time
0 s
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
External current transformer
No
Width
18 mm
Height
93 mm
Depth
127 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.