Electronic overcurrent protection for 24V DC, fix 2A with tripped signal out-, control in-put and supply terminals
Protec. Electronic overcurrent for 24V DC, fixed 2A with signal
Reliable modular elektronic overcurrent protection for 24V DC systems, simple busbar solution, fixed or variable amperages, optionally with control input and tripped message output, plug-in terminals (+ 24V and 0V) for up to 3 loads, robust design, local and (optional) remote-controllable
Relays > Current monitoring relay
Electronic overcurrent protection
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Plug-in connection |
| With detachable clamps (EF003340) | false |
| External power supply required (EF003292) | false |
| Voltage type (supply voltage) (EF002991) | |
| Supply voltage AC 50 Hz (EF007532) | None V |
| Supply voltage AC 60 Hz (EF007533) | None V |
| Supply voltage DC (EF007534) | None V |
| Voltage measuring range (EF002486) | None V |
| Type of current (EF000143) | |
| Current measuring range (EF000417) | 0 A |
| Response value amperage 1 (EF008204) | None A |
| Response value amperage 2 (EF008205) | None A |
| Single-phase under current possible (EF003405) | false |
| Three-phase under current possible (EF003406) | false |
| Single-phase overcurrent possible (EF003407) | false |
| Three-phase overcurrent possible (EF003408) | false |
| Single-phase hysteresis possible (EF003394) | false |
| Three-phase hysteresis possible (EF003395) | false |
| Contains function DC-voltage under current (EF003409) | false |
| Contains function DC-voltage overcurrent (EF003410) | true |
| Function DC-current hysteresis (EF003411) | false |
| Min. adjustable delay-on energization time (EF008190) | 0 s |
| Max. permitted delay-on energization time (EF008189) | 0 s |
| Min. adjustable off-delay time (EF008192) | 0 s |
| Max. permitted off-delay time (EF008191) | 0 s |
| External current transformer (EF001923) | false |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of contacts as normally open contact (EF008256) | 1 |
| Number of contacts as change-over contact (EF008257) | 0 |
| Voltage type (operating voltage) (EF005294) | |
| Operating voltage AC 50 Hz (EF008206) | None V |
| Operating voltage AC 60 Hz (EF008207) | None V |
| Operating voltage DC (EF008208) | None V |
| Rated switch current (EF006706) | None A |
| Width (EF000008) | 18 mm |
| Height (EF000040) | 93 mm |
| Depth (EF000049) | 127 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| PXS24S-e2/F/ORT-IT PXS24S02A001 PXS24S02A001 EN_PXS24S02A001.pdf | 168 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.