Product successfully added to your shopping cart
1SDA066812R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax" > XT1
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2347 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 8cb3ed1b-4dd2-4c55-a8f6-faabe7c2b9ad Italy (IT) |
| Simplified SCIP | 7f55227d-81b0-426c-b95d-87c224a5525b Spain (ES) |
| f02605f6-fb0e-4e86-98af-0814a8d0ba70 Hungary (HU) | |
| d0ab3184-a0e7-41a0-9c0f-b2936d10155f Belgium (BE) | |
| 83abee8b-5b8f-4dae-9018-3f08f8109dfe Germany (DE) | |
| c49eab37-57f8-4b6e-84c4-ef9413dd28c2 Denmark (DK) | |
| 0b417151-96f3-4697-b26c-15be68f6f56b Sweden (SE) | |
| a733aefb-7fc4-4b91-aaf8-0cfa9038a88d Croatia (HR) | |
| c70822c6-3b77-41dc-9438-f29d72d6261c Germany (DE) | |
| 35f94476-ae3c-4f8f-a673-1e1004524daf Germany (DE) | |
| c55964cb-9eba-4808-98b2-9558a3643a72 Czech Republic (CZ) | |
| e4c49f80-81bb-456a-9545-3af28943ceae France (FR) | |
| 57858120-58a5-4f82-8b27-7242054e05d8 Poland (PL) | |
| 21eb8b7f-fbd0-44f2-afbe-65f5b5470087 Finland (FI) | |
| a656bff7-6b0a-4bcb-9873-06bcc001c424 Netherlands (NL) | |
| 85de621d-acc3-4fb3-852b-4537b886822d Norway (NO) | |
| e422f81e-d870-43eb-af88-077488e3c5bc Sweden (SE) | |
| 56123d5f-2c84-40b7-8116-79fa14e412d7 Bulgaria (BG) | |
| 1e925491-bad4-4cda-8f75-8d0f91c758c8 Portugal (PT) | |
| dd28347b-5e19-4326-831a-d3757956d536 Germany (DE) | |
| 7b88bc6a-b066-4793-9f9d-993f2163e806 Poland (PL) | |
| 0cc592fd-cdbe-4e10-aa1d-7efffb9d65e6 Germany (DE) | |
| b29ab876-8a3d-4ccc-9943-c92002afdb31 France (FR) | |
| 8ac237d2-0f40-437a-9c46-6cd5a1142107 Greece (GR) | |
| 06173978-d35f-4fd9-ad70-2c549716b779 Poland (PL) | |
| c1baa18a-7f83-4a85-9554-4483bebe4720 Hungary (HU) | |
| ba8fae24-e97e-45ec-a566-c60a2adc74b4 Estonia (EE) | |
| af8d3bdb-26fb-4075-847f-2b2d365fc2f8 Belgium (BE) | |
| Ordering | |
| Order Code US and Canada | XT1BE4025AFF000XXX |
| E-Number (Finland) | 3640505 |
| EAN | 8015644007195 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 101.6 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.4 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.424 kg |
| Package Level 1 EAN | 8015644007195 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 2 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 25 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 11.25 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 25 kA |
| (230 V AC) 25 kA | |
| (240 V AC) 25 kA | |
| (380 V AC) 18 kA | |
| (415 V AC) 18 kA | |
| (440 V AC) 15 kA | |
| (500 V AC) 8 kA | |
| (525 V AC) 6 kA | |
| (690 V AC) 3 kA | |
| (250 V DC) 2 Poles in Series 18 kA | |
| (500 V DC) 3 Poles in Series 18 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M6 |
| Release | TMD |
| Release Type | TM |
| Setting Range | 17.5...25 A |
| Short-Circuit Performance Level | B |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 6 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0080 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| GL Certificate | 1SDL000163R0103 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000719R0100 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| XT1B 160 TMD 25-450 4p F F - ABB - XT1B160 - 1SDA066812R1 | 89 Kbytes |
![]() |
| XT1B160 1SDA066812R1 ABB XT1B 160 TMD 25-450 4p F F | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.