A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24….690 AC, 50/60 Hz and 24-220 V DC

Ordering

  • EAN:
    7320500094617
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    200 mm
  • Product Net Depth:
    200 mm
  • Product Net Height:
    175 mm
  • Product Net Weight:
    6.6 kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    240 mm
  • Package Level 1 Length:
    240 mm
  • Package Level 1 Height:
    190 mm
  • Package Level 1 Gross Weight:
    7.05 kg

Technical

  • Number of Main Contacts NO:
    4
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    2
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 300 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 270 A
    (690 V) 40 °C 300 A
    (690 V) 70 °C 215 A
  • Rated Operational Current AC-3 (Ie):
    (1000 V) 55 °C 113 A
    (220 / 230 / 240 V) 55 °C 210 A
    (690 V) 55 °C 210 A
    (440 V) 55 °C Q55C415V:210 A
    (440 V) 55 °C 210 A
    (380 / 400 V) 55 °C 210 A
    (500 V) 55 °C 210 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 132 kW
    (1000 V) 160 kW
    (690 V) 160 kW
    (220 / 230 / 240 V) 59 kW
    (380 / 400 V) 110 kW
    (440 V) 110 kW
    (415 V) 110 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 355 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 320 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1680 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 800 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 120 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)Uc (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    DC Operation 24 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1200 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 65 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 52 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 20…40 ms
    Between Coil De-energization and NO Contact Opening 7.5…15 ms
    Between Coil De-energization and NC Contact Closing 10…18 ms
    Between Coil Energization and NC Contact Opening 15…35 ms
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+55 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -50…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 250 A

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching

Datasheet - PDF

Title: Language: Size: Type:
pdf-EK175-40-21 24V DC Contactor - ABB - EK175-40-21 - SK825440-DB English 91 Kbytes pdf-EK175-40-21 24V DC Contactor - ABB - EK175-40-21 - SK825440-DB

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.