Product successfully added to your shopping cart
1SDA056224R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E3
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 90a6a7af-334f-470c-b88a-ea10543433b6 Italy |
| Simplified SCIP | 1f1d6af8-069f-4899-9f5b-857aab24dc15 Germany |
| aabcb92a-3ffa-4ece-ba02-42da5edb8f86 Czech Republic | |
| 0a551d4e-14a6-4a81-908f-20ed07b7b2fe Poland | |
| 880ab38a-c5a5-4b1a-862e-94629a22c117 Norway | |
| 0e87e91e-d1e2-472a-bca2-cef9d4253273 Croatia | |
| 001e6165-4c0d-4721-85f5-955c27bd5308 Belgium | |
| eeffd042-5bfb-4b97-a07b-28d9f9b1bf29 Hungary | |
| a2deb022-40d6-490b-8b65-09b4871721df Poland | |
| 7967de4d-14d3-4a7b-bcb3-2778f716b6aa Netherlands | |
| e000ca98-14d6-4620-b930-ee3fc00aa74d Denmark | |
| ff994467-0f7b-4aff-9812-5064e09456fb Poland | |
| 42c4b1a6-50bb-453c-9dff-b15c59feacbb Finland | |
| 284fdabf-5589-43fd-82b7-eaebd09594b9 Germany | |
| 29eb0dab-6d9a-453a-b3e0-2a32f278cadd Germany | |
| c0c74f86-879b-4910-aa60-7ddf25405204 Portugal | |
| abefbc91-8d48-4ad3-a2e8-eb5ac88242bd Bulgaria | |
| cd2ea83d-3978-43c1-b6eb-a571d2aae8fe Spain | |
| d3a56146-431e-426e-acd1-00be2f6b132d France | |
| 9225be4a-61e4-4e14-83a3-3fe8fe9e831b France | |
| ab53f988-a5bc-4aca-b9d8-36982837ccfe Sweden | |
| 7b181bad-91d1-4739-be43-ec680f19d20d Sweden | |
| 5b3d6df6-0e53-4811-9aaa-f13c90ac7940 Estonia | |
| b1437a3f-15c1-4ae0-8267-fbf64929be9f Germany | |
| dfbc254e-9ec8-421a-91b6-ec50d786d482 Germany | |
| b87fde25-d94f-4c47-9458-f0eb7b2ecc5a Belgium | |
| 3586b402-ac6c-47fe-809d-23ce7ce5361f Greece | |
| c375f1a0-b173-4db5-bc51-ee1667c1b5c5 Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575649 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644575649 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 150 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1600 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E3S 1600 PR121/P-LI In1600A 3p W MP - ABB - E3S1600 - 1SDA056224R1 | 90 Kbytes |
![]() |
| E3S1600 1SDA056224R1 ABB E3S 1600 PR121/P-LI In 1600A 3p W MP | 79 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.