Product successfully added to your shopping cart
1SDA071609R1
ABB
1
E2.2H 1250 Ekip Hi-Touch LSIG 4p F HR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | c4a3326f-1da7-42ce-889a-93201f9ca8fa Italy |
| Simplified SCIP | c4be3961-2591-41c4-b0b2-f6560809427d France |
| eb5bc04d-1708-44ec-b805-1032f7493e91 Sweden | |
| f0d5373a-9b31-4467-8f62-95b9995754d7 Poland | |
| 170479ab-68e6-45a9-a29c-e3c86184830b Belgium | |
| bef5562d-c307-4314-ade5-cb774f040bf6 Norway | |
| a798c37a-4587-418c-aeb0-b6faf70589ca Germany | |
| cafd8d36-c28c-4b4e-9124-92f09cc8f3a6 Germany | |
| 5b6d95e7-faa2-43f5-aa11-925a4cf62b25 Finland | |
| 836eb208-1f2f-42cd-9754-4f0de899fc3d Bulgaria | |
| 1a756ad4-d278-4cd8-a54e-d2a9e88931d0 Denmark | |
| b474cf3b-fa2f-4e82-af91-822b2139257f Croatia | |
| bef5562d-c307-4314-ade5-cb774f040bf6 Norway | |
| 0459696e-89d3-4329-ae8b-8f7e56d867ce Germany | |
| 1a756ad4-d278-4cd8-a54e-d2a9e88931d0 Denmark | |
| d899b368-281d-450b-aa9f-a078b6c3a2f6 Hungary | |
| 8c036568-96c7-45e4-8225-1dc765a3b7fe Poland | |
| a11cb447-a635-4fbc-8976-ce3ab2aafc99 Czech Republic | |
| 0459696e-89d3-4329-ae8b-8f7e56d867ce Germany | |
| f0d5373a-9b31-4467-8f62-95b9995754d7 Poland | |
| eb5bc04d-1708-44ec-b805-1032f7493e91 Sweden | |
| a798c37a-4587-418c-aeb0-b6faf70589ca Germany | |
| 170479ab-68e6-45a9-a29c-e3c86184830b Belgium | |
| 90e1df21-e329-408d-b48c-20eacc0445fc Portugal | |
| e85f3a2a-6485-4204-9262-1da87e1f6e56 Poland | |
| a49d9755-c194-4c17-9c59-da091221898c Belgium | |
| a10ef32d-cd96-4c31-ad8f-b45f65e53fc9 Netherlands | |
| 8c036568-96c7-45e4-8225-1dc765a3b7fe Poland | |
| 69dcf4d8-600f-4a5f-aa64-2b4c7f98687a Greece | |
| fc8c958a-29da-446c-a321-8f99de67773e Hungary | |
| 491b806c-4d72-4512-b2bb-1705ec5fb0ae Germany | |
| 129f9cb3-c9a3-42cf-9d32-b966a6dbfa2f Germany | |
| a11cb447-a635-4fbc-8976-ce3ab2aafc99 Czech Republic | |
| 836eb208-1f2f-42cd-9754-4f0de899fc3d Bulgaria | |
| 69dcf4d8-600f-4a5f-aa64-2b4c7f98687a Greece | |
| cafd8d36-c28c-4b4e-9124-92f09cc8f3a6 Germany | |
| 90e1df21-e329-408d-b48c-20eacc0445fc Portugal | |
| 5b6d95e7-faa2-43f5-aa11-925a4cf62b25 Finland | |
| c4be3961-2591-41c4-b0b2-f6560809427d France | |
| 9c1ec528-ff87-4e37-b797-97821bd38846 Sweden | |
| a10ef32d-cd96-4c31-ad8f-b45f65e53fc9 Netherlands | |
| b474cf3b-fa2f-4e82-af91-822b2139257f Croatia | |
| 23538cf4-40cf-4259-a268-939d252b825b Spain | |
| a49d9755-c194-4c17-9c59-da091221898c Belgium | |
| d899b368-281d-450b-aa9f-a078b6c3a2f6 Hungary | |
| 4e9c3d25-6d3d-4de7-b0bc-d7c901ba8785 Estonia | |
| 23538cf4-40cf-4259-a268-939d252b825b Spain | |
| 743a253d-3206-4ad4-8384-90942ff763a2 France | |
| e85f3a2a-6485-4204-9262-1da87e1f6e56 Poland | |
| fc8c958a-29da-446c-a321-8f99de67773e Hungary | |
| 4e9c3d25-6d3d-4de7-b0bc-d7c901ba8785 Estonia | |
| 491b806c-4d72-4512-b2bb-1705ec5fb0ae Germany | |
| 129f9cb3-c9a3-42cf-9d32-b966a6dbfa2f Germany | |
| 9c1ec528-ff87-4e37-b797-97821bd38846 Sweden | |
| 743a253d-3206-4ad4-8384-90942ff763a2 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBHREHBK200A000000XX |
| EAN | 8015644754594 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644754594 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0123 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 83 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2H 1250 Ekip Hi-Touch LSIG 4p F HR - ABB - E2.2H1250 - 1SDA071609R1 | 90 Kbytes |
![]() |
| E2.2H1250 1SDA071609R1 ABB E2.2H 1250 Ekip Hi-Touch LSIG 4p F HR | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.