Product successfully added to your shopping cart
1SDA101129R1
ABB
1
XT7S 1600 Ekip Touch LSI In=1600A 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | d4d1f6b7-2706-41d9-bd74-4411e81553da Italy |
| Simplified SCIP | f1b191e5-5042-42bb-bb56-5e94813e5157 Estonia |
| c4f1f0ec-e4f2-4c47-bde4-8648a488d427 Germany | |
| e2109f17-9df8-41d9-bdc5-40b89fdec160 Bulgaria | |
| 6311dad7-c8fd-49d1-b4cf-1df9504fa556 Denmark | |
| 57be4cc6-29f5-4f5c-9ac9-1a890b232ff2 Belgium | |
| 47244850-62b8-4a51-a393-d2dbe8d5ab05 Finland | |
| bf0f6957-0220-429b-9a5e-0755ea7fcec8 Poland | |
| 6d443e71-8961-469f-bf2c-053f4009a5bf Spain | |
| 3b0de209-1e61-42ad-a647-321255d37bea Norway | |
| a262b14e-905f-4e85-9734-fa4fa4a9ce9c Belgium | |
| 1d843f72-245e-4c9c-9a34-0affe461064e Sweden | |
| fea6b70e-36a6-463b-ba44-487ff1890c82 Germany | |
| 45b70f56-85ec-4788-bc5c-96ad8e9fbabc Czech Republic | |
| 6311dad7-c8fd-49d1-b4cf-1df9504fa556 Denmark | |
| bf0f6957-0220-429b-9a5e-0755ea7fcec8 Poland | |
| a262b14e-905f-4e85-9734-fa4fa4a9ce9c Belgium | |
| 5648e6db-0e81-45e3-a5da-4d80c83953db Germany | |
| 47244850-62b8-4a51-a393-d2dbe8d5ab05 Finland | |
| ec096d25-e488-48d5-a305-aa0c221a06e3 Poland | |
| fea6b70e-36a6-463b-ba44-487ff1890c82 Germany | |
| 20c4a1db-41c7-4701-96b0-8781198adae3 Greece | |
| 1114e6ee-d84e-445d-b4c3-eb5ff27797b8 Portugal | |
| 20c4a1db-41c7-4701-96b0-8781198adae3 Greece | |
| 594b9777-45fa-4a3e-a02b-4b4be50d2297 France | |
| 5648e6db-0e81-45e3-a5da-4d80c83953db Germany | |
| 3b0de209-1e61-42ad-a647-321255d37bea Norway | |
| c6f392e2-dac2-42d0-9d40-49605e98a451 Croatia | |
| 6a4c3e42-b8bb-4cc4-9e7a-26afd4a19e12 Poland | |
| 1114e6ee-d84e-445d-b4c3-eb5ff27797b8 Portugal | |
| 91bc4e44-0985-4fb9-9077-41730955ff15 Germany | |
| 931c390a-2e14-40c6-ab28-12d46dbdec54 Germany | |
| b8f16067-3090-47b1-bbd1-3e27e95f2e76 Netherlands | |
| 5810d930-e3c6-4a9f-89d4-437d9c3b7b2b Sweden | |
| 6d443e71-8961-469f-bf2c-053f4009a5bf Spain | |
| 931c390a-2e14-40c6-ab28-12d46dbdec54 Germany | |
| 91bc4e44-0985-4fb9-9077-41730955ff15 Germany | |
| 3ff816f4-abdc-4906-baf5-62d44cf7c5b7 Hungary | |
| 8f29e684-927f-4f20-a9bb-c859721165ea France | |
| c4f1f0ec-e4f2-4c47-bde4-8648a488d427 Germany | |
| 1d843f72-245e-4c9c-9a34-0affe461064e Sweden | |
| 6a4c3e42-b8bb-4cc4-9e7a-26afd4a19e12 Poland | |
| f1b191e5-5042-42bb-bb56-5e94813e5157 Estonia | |
| 57be4cc6-29f5-4f5c-9ac9-1a890b232ff2 Belgium | |
| 594b9777-45fa-4a3e-a02b-4b4be50d2297 France | |
| 5810d930-e3c6-4a9f-89d4-437d9c3b7b2b Sweden | |
| ec096d25-e488-48d5-a305-aa0c221a06e3 Poland | |
| 2dd5d4e5-34e3-4a92-bade-93ff7281f4e7 Hungary | |
| 3ff816f4-abdc-4906-baf5-62d44cf7c5b7 Hungary | |
| 8f29e684-927f-4f20-a9bb-c859721165ea France | |
| b8f16067-3090-47b1-bbd1-3e27e95f2e76 Netherlands | |
| c6f392e2-dac2-42d0-9d40-49605e98a451 Croatia | |
| 45b70f56-85ec-4788-bc5c-96ad8e9fbabc Czech Republic | |
| 2dd5d4e5-34e3-4a92-bade-93ff7281f4e7 Hungary | |
| e2109f17-9df8-41d9-bdc5-40b89fdec160 Bulgaria | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE416FPFF000XXX |
| E-Number (Norway) | 4380828 |
| EAN | 8056221014328 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 12.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 360 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221014328 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1390 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 94 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA101129R1 1SDA101129R1 EN_1SDA101129R1.pdf | 614 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.