Produto adicionado com sucesso ao seu carrinho de compras
PRC 3-FC-MS6 12-16
1014529
PHOENIX_CONTACT
1
Conectores circulares (cabo-lado), uma Gama de artigos: república popular da CHINA, Conector, material da carcaça: EPI, cor: preto, número de posições: 3, min. condutor de secção transversal de 1,5 mm2, max. condutor de seção transversal: 6 mm2, nom. tensão: 690 V AC, corrente nominal: 35, método de Conexão: conexão a Parafuso, Tipo de contato: Pin, min. diâmetro do cabo: 12 mm, máx. cabo diâmetro: 16 mm
Circular connectors (cable-side), Range of articles: PRC, Connector, housing material: PPE, color: black, number of positions: 3, min. conductor cross section: 1.5 mm², max. conductor cross section: 6 mm², nom. voltage: 690 V AC, rated current: 35 A, Connection method: Screw connection, Type of contact: Pin, min. cable diameter: 12 mm, max. cable diameter: 16 mm
Sensores > Base de ligação para sensores e atuadores
Conexão de dispositivos de campo
* Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
Chave de encomenda | 1014529 |
---|---|
Quantidade de embalagem | 1 UNID |
GTIN (EAN) | 4055626494364 |
Peso por unidade (exclusive embalagem) | 81,000 g |
Número do imposto alfandegário | 85366990 |
País de origem | PL (Polónia) |
Number of positions | 3 |
---|---|
Protection class | II |
Color | black |
Locking type | Snap-in locking |
Insertion/withdrawal cycles | 100 |
Degree of protection (when plugged in) | IP66 / IP68 (2m / 24h) / IP69K |
Width | 37.6 mm |
Height | 37.6 mm |
Length | 105 mm |
Rated current | 35 A (With 6 mm² conductor cross section in accordance with IEC 61984) |
---|---|
32 A (With 6 mm² conductor cross section in accordance with IEC 61535) | |
35 A (With 6 mm²/AWG 10, in accordance with UL 2238) | |
Nominal voltage ATD | 690 V AC (in accordance with IEC 61984) |
500 V AC (in accordance with IEC 61535/2 PfG 1915) | |
600 V AC (In accordance with UL 2238) | |
Rated voltage (III/2) | 690 V |
Stripping length | 12 mm |
Torque | max. 1 Nm (Contact screw) |
Type of contact | Pin |
Stripping length of the sheath | 50 mm |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 6 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 1.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 6 mm² |
Conductor cross section solid min. | 1.5 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 4 mm² |
Conductor cross section flexible max. | 6 mm² |
Connection method | Screw connection |
Degree of protection | IP66 / IP68 (2m / 24h) / IP69K |
Stripping length of the individual wire | 12 mm () |
Cable diameter1 | 12 mm ... 16 mm |
Contact material | Cu alloy |
---|---|
Contact surface material | silver-plated |
Contact carrier material | PPE |
Flammability rating according to UL 94 | V0 |
Housing material | PPE |
Seal material | EPDM |
O-ring material | EPDM |
Cable seal material | EPDM |
Cable gland material | PPE |
Color of the housing part | black |
Knurl material | PPE |
Halogen-free | yes |
---|---|
Flammability rating according to UL 94 | V0 |
Safety note | • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. |
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. | |
WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. | |
• Assembled products may not be manipulated or improperly opened. | |
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). | |
• When using the product in direct connection with third-party manufacturers, the user is responsible. | |
• For operating voltages > 50 V AC, conductive connector housings must be grounded | |
• Ensure that the protective or functional ground has been properly connected. | |
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector | |
• Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product | |
• Only use tools recommended by Phoenix Contact | |
• The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product. | |
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products | |
• Operate the connector only when it is fully plugged in. | |
• Operate the connector only when it is fully plugged in and interlocked. | |
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. | |
• Observe the minimum bending radius of the cable. Lay the cable without twisting it. | |
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
Título: | Tamanho: | Tipo: |
---|---|---|
PDF CATALOG PHOENIX CONNECTORS EN.pdf | 57 Mbytes |
Não há comentários do produto ainda.
Avaliação: | |
Nome: | |
Email: | |
Título: | |
Opinión: | |
Você recomendaria esse produto para comprar? | |
Adicionar avaliação |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.