ANUNCIAR
MACX MCR-EX-AP-2REL-2DI-LP 1292331 PHOENIX CONTACT O módulo de relé separa os circuitos de controle e sinal .. Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

MACX MCR-EX-AP-2REL-2DI-LP 1292331 PHOENIX CONTACT O módulo de relé separa os circuitos de controle e sinal ..

MACX MCR-EX-AP-2REL-2DI-LP

1292331

PHOENIX_CONTACT

O módulo de relé separa os circuitos de controle e sinal Ex i e não Ex i e serve para controle intrinsecamente seguro de circuitos de corrente de campo Ex i por meio de um relé inversor por canal. Configuração padrão, alimentada por loop, separação de 4 vias, nível de integridade de segurança (SIL, IEC 61508): 2, conexão a parafuso

Ex i-Relay module isolates binary Ex i and non Ex i signal and control circuits, and is used for intrinsically safe activation of Ex i field currents via one changeover contact relay per channel. Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Screw connection

Mais detalhes


Aparelhos elétricos de baixa tensão > Acessórios para a tecnologia de comutação por baixa tensão

Interface

Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT

Preço total: $339.51
Preço unitário: $339.51
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Best sellers

Mais informação



Dados técnicos

Notes
GeneralInstallation conditions influence the ambient temperature.
Please refer to the operating instructions.

Product properties
Product typeRelay Module
Product familyMACX Analog
No. of channels2

Electrical properties
No. of channels2
Electrical isolation4-way isolation
Electrical isolation Input/output IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage375 VPP
Electrical isolation Input 1 / input 2
Test voltage350 V (50 Hz, 60 s)
Supply
Supply voltage rangeloop-powered, no external supply necessary
Power dissipation≤ 0.4 W

Input data
Control
Description of the inputControl input, not intrinsically safe
Voltage input signal12 V ... 31.2 V (Switching signal)
Current consumption< 25 mA (12 V)
< 17 mA (24 V ... 31.2 V)

Output data
Switching: Relay
Output descriptionintrinsically safe
Contact switching type1 changeover contact per channel
Minimum switching voltage1 V (1 mA)
Maximum switching voltage45 V DC (0.25 A)
30 V DC (4 A)
45 V AC (4 A, cos ϕ >0.7)
Typical response time≤ 10 ms
Typical turn-off time≤ 10 ms
Switching frequency≤ 15 Hz

Connection data
Cross section AWG(converted acc. to IEC)
Connection methodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Ex data
Ex installation (EPL)Gc
Ex i circuits (EPL)Ga
Da
Ma
Safety data
Input voltage Ui45 V AC
Input current Ii4 A
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible
Safety-related maximum voltage Um253 V AC
Safety data
Input voltage Ui45 V DC
Input current Ii0.25 A
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible
Safety-related maximum voltage Um253 V AC
Safety data
Input voltage Ui30 V DC
Input current Ii4 A
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible
Safety-related maximum voltage Um253 V AC

Dimensions
Dimensional drawingkrbhdfxwui.jpg
Width17.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications
Flammability rating according to UL 94V0
Housing materialPolyamide (PA 6.6)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (Terminal blocks)
IP30 (Housing)
Ambient temperature (operation)-20 °C ... 70 °C (Stand-alone device: any mounting position)
-20 °C ... 70 °C (Group assembly: vertical DIN rail without circulating air)
-20 °C ... 70 °C (Group assembly: vertical DIN rail with circulating air)
-20 °C ... 70 °C (Group assembly: horizontal DIN rail without circulating air)
-20 °C ... 70 °C (Group assembly: horizontal DIN rail with circulating air)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)≤ 95 % (non-condensing)

Approvals
ATEX
Identification II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3(1) G Ex ec nC [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
IECEx
Identification[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec nC [ia Ga] IIC T4 Gc
[Ex ia Ma] I
Safety Integrity Level (SIL, IEC 61508)
Identification2

EMC data
Electromagnetic compatibilityTested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21

Standards and regulations
Electrical isolation4-way isolation

Mounting
Mounting typeNS 35/15, NS 35/7,5
Mounting positionvertical, horizontal

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.