FB-DIAG/FF/LI
2316284
PHOENIX_CONTACT
1
Acoplador de equipamentos
Módulo de diagnóstico de campo, instalação de predecessor, com conector de encaixe lateral
Field diagnostics module, legacy installation, includes pluggable side connector
Segurança e Comunicações
Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Product type | Device coupler |
| Supply | |
| Supply voltage range | 9 V DC ... 32 V DC |
| Typical current consumption | 27 mA |
| Max. current consumption | 29 mA |
| Safety data | |
| Input voltage Ui | 32 V DC |
| Input current Ii | 274 mA (IIC) |
| 570 mA (IIB) | |
| Inductance Li | 10 µH |
| Capacitance Ci | 0 µF |
| Signal | PROFIBUS |
| FOUNDATION Fieldbus | |
| Data: FOUNDATION Fieldbus | |
| Connection method | Pluggable screw connection with test points |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section AWG max. | 12 |
| Conductor cross section AWG min. | 24 |
| Dimensional drawing | ![]() |
| Width | 17.7 mm |
| Height | 93.9 mm |
| Depth | 70.4 mm |
| Color | green |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 95 % (non-condensing) |
| Conformity/Approvals | |
| Conformance | IEC 61158-2 |
| Fieldbus Foundation | FF-830 |
| EN | EN 61326, EN 60068-2-27, EN 60068-2-6 |
| NE | NE21 |
| Ex data | |
| ATEX | Sira 13ATEX4149X; II 3G Ex nA [ic] IIC T4 Gc |
| IECEx | IECEx SIR 13.0060X; Ex nA [ic] IIC T4 Gc |
| CSA, USA/Canada | Class I, Div. 2, Groups A,B,C,D; Ex nA nL IIC T4 Gc Class I, Zone 2, AEx nA nC IIC T4 Gc |
| Standards/regulations | |
| Standards/regulations | Ring wave noise immunity in acc. with IEC 61000-4-12 |
| Standards/regulations | |
| Standards/regulations | Dry heat in acc. with IEC 61131-2 |
| Standards/regulations | |
| Standards/regulations | Damp heat in acc. with IEC 61131-2 |
| Standards/regulations | |
| Standards/regulations | Shock and vibration in acc. with EN 61131-2 and EN 50178 |
| Standards/regulations | IEC 61158-2 |
| Mounting type | DIN rail mounting |
| Mounting position | Any orientation on DIN rail, NS 35, in acc. with EN 60715 |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.