Transformer-protective circuit-breaker, 3p, Ir=0.16-0.25A, screw connection

Interruptor de proteção do transformador 3 polo Ir=0.16-0.25 A Conexão

Eaton Moeller® series PKZM0 Transformer-protective circuit-breaker, 3p, Ir=0.16-0.25A, screw connection

Disjuntor de transformador de acordo com IEC/EN60947, tamanho de 3 polos PKZM0, com sobrecarga ajustável e desconexão de curto-circuito não retardada, sensível a falhas de fase, aparafusado e pressionado, com terminal de parafuso, dimensão de instalação da tampa 45 mm, tensão nominal de operação Ue 690V, grau de proteção IP20, à prova de dedos de acordo com VDE 0106 T. 100, Acessórios: Contato Auxiliar, Liberação de Tensão

Mais detalhes


Aparelhos elétricos de baixa tensão > Interruptor para proteção de transformadores, geradores e sistemas

Chaves de proteção do motor

Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

Preço total: $79.70
Preço unitário: $79.70
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series PKZM0 Transformer-protective circuit-breaker
Catalog Number
088908
EAN
4015080889083
Product Length/Depth
76 mm
Product Height
93 mm
Product Width
45 mm
Product Weight
0.246 kg
Certifications
IEC/EN 60947
VDE 0660
Model Code
PKZM0-0,25-T

Funcionalidades e Funções

Actuator type
Turn button
Features
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)
Fitted with:
Switched-off indicator
Functions
For the protection of transformers with a high inrush current
Transformer protection
Number of poles
Three-pole

Geral

Connection
Screw terminals
Lifespan, electrical
100,000 operations
Lifespan, mechanical
100,000 Operations
Mounting Method
DIN rail (top hat rail) mounting optional
Mounting position
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
Operating frequency
40 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Transformer protective circuit breaker
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
6000 V AC
Shock resistance
25 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Suitable for
Also motors with efficiency class IE3
DIN rail (top hat rail) mounting
Temperature compensation
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°
-25 - 55 °C, Operating range

Condições meteorológicas

Altitude
Max. 2000 m
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Capacidades dos terminais

Terminal capacity (solid)
2 x (1 - 6) mm²
1 x (1 - 6) mm²
Terminal capacity (solid/stranded AWG)
18 - 10
Stripping length (main cable)
10 mm
Tightening torque
1 Nm, Screw terminals, Control circuit cables
1.7 Nm, Screw terminals, Main cable

Classificação elétrica

Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated operational current (Ie)
0.25 A
Rated operational power at AC-3, 220/230 V, 50 Hz
0 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
0.06 kW
Rated operational voltage (Ue) - min
690 V
Rated operational voltage (Ue) - max
690 V
Rated uninterrupted current (Iu)
0.25 A

Classificação de curto-circuito

Short-circuit current
60 kA DC, up to 250 V DC, Main conducting paths
Short-circuit current rating (group protection)
50 kA, 600 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse, SCCR (UL/CSA)
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA)
Short-circuit release
± 20% tolerance, Trip blocks
Basic device, fixed 20 x Iu, Trip Blocks
4.25 A, Irm, Setting range max.
Rated short-circuit breaking capacity Ics at 400 V AC
150 kA
Rated short-circuit breaking capacity Icu at 400 V AC
150 kA
Rated short-circuit breaking capacity Icu at 440 V AC
150 kA
Rated short-circuit breaking capacity Ics at 440 V AC
150 kA
Rated short-circuit breaking capacity Icu at 500 V AC
150 kA
Rated short-circuit breaking capacity Ics at 500 V AC
150 kA
Rated short-circuit breaking capacity Icu at 690 V AC
150 kA
Rated short-circuit breaking capacity Ics at 690 V AC
150 kA

Contactos

Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0

Blocos de disparo

Overload release current setting - min
0.16 A
Overload release current setting - max
0.25 A

Verificação do design

Equipment heat dissipation, current-dependent Pvid
4.59 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.53 W
Rated operational current for specified heat dissipation (In)
0.25 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 088908 Componentes industriais para Baixa Tensão (EC000228)
Característica Valor
Corrente permanente nominal Iu (EF001389) 0.25 A
Intervalo de tensões especificadas (EF003977) 690 V
Corrente nominal de comutação de curto-circuito Icu a 400 V, 50 Hz (EF007048) 150 kA
Configuração de corrente da proteção contra sobrecargas (EF002336) 0.16 A
Intervalo de configuração do atraso de rearme após curto-circuíto (EF007129) 0 A
Faixa de ajuste da disparo em curto-circuito não retardada (EF007131) 4.25 A
Potência dissipada (EF005387) 4.59 W
Construção do dispositivo (EF008240) Técnica de instalação fixa para dispositivo embutido
Proteção integrada de falta à terra (EF007296) Não
Tipo de conexão elétrica do circuito principal (EF006819) Ligação com parafuso
Adequado para montagem em calha DIN (calha superior) (EF007250) Sim
Montagem em calha DIN (calha superior) opcional (EF008904) Sim
Número de contatos auxiliares como contato normalmente fechado (EF001377) 0
Número de contatos auxiliares como contato normalmente aberto (EF001376) 0
Número de contatos auxiliares como contato de comutação (EF003531) 0
Relé de sinalização de gatilho disponível (EF007006) Sim
Com passagem de subtensão integrada (EF001390) Não
Número de polos (EF001391) 3
Posição de conexão do circuito de corrente principal (EF006671) Outro
Tipo de elemento de controlo (EF006976) Botão rotativo
Dispositivo completo com unidade de proteção (EF008906) Sim
Acionamento do motor integrado (EF006697) Não
Acionamento do motor opcional (EF007386) Não
Grau de proteção (IP) (EF005474) IP20

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.