ANUNCIAR
E-PKZ01-SVB 281635 Y7-281635 EATON ELECTRIC Insulated enclosure, flush mounting, for PKZ01, +padlocking feat.. Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

E-PKZ01-SVB 281635 Y7-281635 EATON ELECTRIC Insulated enclosure, flush mounting, for PKZ01, +padlocking feat..

E-PKZ01-SVB

281635

Y7-281635

EATON-MOELLER

Insulated enclosure, flush mounting, for PKZ01, +padlocking feature yellow

Gabinete isolado embutido IP65 para PKZ01 + função de travamento

Eaton Moeller® series E-PKZ0 Insulated enclosure, E-PKZ0, H x W x D = 129 x 90 x 128 mm, flush-mounted, + yellow padlock device

Caixa de disjuntores de proteção do motor para integração direta na máquina

Mais detalhes


Aparelhos elétricos de baixa tensão > Caixa vazia para aparamenta

Chaves de proteção do motor

Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

Preço total: $28.01
Preço unitário: $28.01
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series E-PKZ0 Accessory Insulated enclosure
Catalog Number
281635
Product Length/Depth
128 mm
Product Height
129 mm
Product Width
90 mm
Product Weight
0.265 kg
Certifications
CSA Class No.: 3211-05
UL Category Control No.: NLRV
CSA-C22.2 No. 14
IEC/EN 60947-4-1
UL
CSA
UL File No.: E36332
CE
CSA File No.: 165628
UL 508
Model Code
E-PKZ01-SVB

Funcionalidades e Funções

Enclosure material
Plastic
Features
Can be locked in 0 position
Fitted with:
PE(N) terminal

Geral

Degree of protection (front side)
IP65
Model
Built-in
Product category
Accessories
Suitable for
Emergency stop

Condições meteorológicas

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C

Verificação do design

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 281635 Componentes industriais para Baixa Tensão (EC000712)
Característica Valor
Material da caixa protetora (EF001596) Plástico
Largura (EF000008) 90 mm
Altura (EF000040) 129 mm
Profundidade (EF000049) 128 mm
Com tampa transparente (EF001094) Não
Adequado para paragem de emergência (EF001433) Sim
Modelo (EF000010) Instalado
Grau de proteção (IP) (EF005474) IP65
Grau de proteção (NEMA) (EF011959) Outro

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.