Eaton XN-312 Gateway to bus system CANopen

Pasarela digital para bus de campo abierto CANopen en forma de módulo de corte del sistema de E/S XN300 sin fuente de alimentación; consumo total de corriente a 24 V: 0 mA

Más detalles


Controladores industriales (PLC) > Módulo de comunicación de periférico descentralizado de bus de campo

Módulos E/S Remotas XN300

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $203.74
Precio unitario: $203.74
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton XN-312 Gateway
Catalog Number
178782
EAN
7640130098442
Product Length/Depth
104.2 mm
Product Height
16.8 mm
Product Width
80.3 mm
Product Weight
0.061 kg
Certifications
CE
DNV GL
IEC/EN 61000-6-2
CULus
IEC/EN 61131-2
UL File No.: E135462
IEC/EN 61000-6-4
UL508
Rated data for terminations according to IEC/EN 60947-7-1
Model Code
XN-312-GW-CAN

Features & Functions

Features
Fieldbus connection over separate bus coupler possible
Fitted with:
Potential separation

General

Admissible range
18 - 30 V DC, Networking
19.2 - 30 V DC, Networking
Configuration
Maximum station configuration: 32 modules (XN-322) in slice design
Degree of protection
IP20
Mounting method
Rail mounting possible
Residual ripple
According to EN 61131-2
Type
Used with
XN-322-…
XN300
Voltage type
DC

Ambient conditions, mechanical

Drop and topple
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Shock resistance
Mechanical, According to IEC/EN 60068-2-27
Vibration resistance
According to IEC/EN 60068-2-6

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
85 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Relative humidity
5 - 95 % (non-condensing)

Electro magnetic compatibility

Air discharge
According to EN 61131-2
Burst impulse
According to IEC/EN 61131-2
Contact discharge
According to EN 61131-2
Electromagnetic fields
According to EN 61131-2
Emitted interference
30 - 230 MHz (radiated, high frequency, according to EN 61131-2)
230 - 1000 MHz (radiated, high frequency, according to EN 61131-2)
Radiated RFI
IEC/EN 61131-2
Surge rating
According to IEC/EN 61131-2
Voltage dips
According to EN 61131-2 (Voltage fluctuations/voltage dips)

Terminal capacities

Terminal capacity
0.2 - 1.5 mm², flexible without ferrule, H07V-K
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm², solid, H07V-U
0.25 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Gauge pin
A1 (according to IEC/EN 60947-1)
Stripping length (main cable)
10 mm

Electrical rating

Supply voltage
4.7 - 5.3 V DC
Supply voltage at AC, 50 Hz - min
0 V
Supply voltage at AC, 50 Hz - max
0 V
Supply voltage at DC - min
18 V
Supply voltage at DC - max
30 V

Communication

Addressing
Address set via DIP switch
Bus termination
Via DIP switch, Networking
Connection type
Push-In spring-cage terminals, Field bus
Push-In spring-cage terminals, Connection design in TOP direction
Data transfer rate
Setting through DIP switch or automatically
1000 kBit/s, Networking
10 kBit/s, Networking
125 kBit/s, Networking
20 kBit/s, Networking
500 kBit/s, Networking
50 kBit/s, Networking
250 kBit/s, Networking
800 kBit/s, Networking
Field voltage
24 V DC (UL)
Interfaces
CANopen®, Field bus connection
Mini-USB Type B (Service interface)
Protocol
CAN
CANopen®
Other bus systems

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Yes

Design verification

Static heat dissipation, non-current-dependent Pvs
2.4 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 178782 Controladores lógicos programables PLC (EC001604)
Característica Valor
Tensión de alimentación 50 Hz CA (EF007532) 0 V
Tensión de alimentación 60 Hz CA (EF007533) 0 V
Tensión de alimentación CC (EF007534) 18 V
Tipo de tensión de alimentación (EF002991) CC
Número de interfaces HW CAN (EF017563) 1
Número de interfaces HW USB (EF003025) 1
Número de interfaces HW Otras (EF003027) 1
Soporta el protocolo EtherCAT (EF017564) No
Soporta el protocolo TCP/IP (EF003050) No
Soporta el protocolo PROFIBUS (EF003052) No
Soporta el protocolo CAN (EF003053)
Soporta el protocolo INTERBUS (EF003054) No
Soporta el protocolo ASI (EF003051) No
Soporta protocolo KNX (EF003055) No
Soporta el protocolo Modbus (EF003057) No
Soporta el protocolo de autopista de datos (EF003058) No
Soporta el protocolo DeviceNet (EF003059) No
Soporta el protocolo SUCONET (EF003060) No
Soporta el protocolo LON (EF003017) No
Soporta el protocolo SERCOS (EF006657) No
Soporta el protocolo PROFINET IO (EF007525) No
Soporta el protocolo PROFINET CBA (EF007524) No
Soporta el protocolo Foundation Fieldbus (EF007522) No
Soporta el protocolo Ethernet/IP (EF007521) No
Soporta el protocolo AS-Interface Safety at Work (EF007519) No
Soporta el protocolo DeviceNet Safety (EF007520) No
Soporta el protocolo de seguridad INTERBUS (EF006662) No
Soporta el protocolo PROFIsafe (EF007526) No
Soporta el protocolo SafetyBUS p (EF007527) No
Soporta el protocolo para otros sistemas bus (EF003062)
Estándar inalámbrico Bluetooth (EF007178) No
Estándar de radio WLAN 802.11 (EF007179) No
Estándar de radio GPRS (EF008523) No
Estándar de radio eGPRS (EF009703) No
Estándar de radio GSM (EF008524) No
Estándar de radio LTE (EF009709) No
Estándar de radio UMTS (EF008525) No
Maestro de enlace E/S (EF007298) No
Componente del sistema (EF004118)
Grado de protección (IP) (EF005474) IP20
Con aislamiento galvánico (EF003272)
Conexión de bus de campo posible a través de un acoplador de bus separado (EF004002)
Montaje en carril posible (EF003972)
Montaje en pared/directo posible (EF007020) No
Instalación frontal posible (EF007016) No
Montaje en rack posible (EF007018) No
Apto para funciones de seguridad (EF001597) No
SIL según IEC 61508 (EF009889) Ninguno
Nivel de rendimiento según EN ISO 13849-1 (EF007399) Ninguno
Equipos asociados (Ex ia) (EF004141) No
Equipos asociados (Ex ib) (EF004142) No
Categoría de protección contra explosiones para gas (EF003997) Ninguno
Categoría de protección contra explosiones para polvo (EF003998) Ninguno
Certificado para áreas peligrosas UL clase I (EF017622) No
Certificado para UL clase II (EF017625) No
Certificado para áreas peligrosas UL Clase III (EF017627) No
Certificado para áreas peligrosas UL División 1 (EF017628) No
Certificado para áreas peligrosas UL División 2 (EF017629) No
Certificado para áreas peligrosas grupo A (acetileno) (EF017632) No
Certificado para áreas peligrosas grupo B (hidrógeno) (EF017633) No
Certificado para áreas peligrosas grupo C (etileno) (EF017635) No
Certificado para áreas peligrosas grupo D (propano) (EF017636) No
Certificado para áreas peligrosas grupo E (polvos metálicos) (EF017637) No
Certificado para áreas peligrosas grupo F (polvos carbonosos) (EF017638) No
Certificado para áreas peligrosas grupo G (polvos no conductores) (EF017639) No
Anchura (EF000008) 80.3 mm
Altura (EF000040) 16.8 mm
Profundidad (EF000049) 104.2 mm

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.