7KM5212-6CA00-1EA8 SIEMENS SENTRON, measuring device, 7KM PAC5100, strd mount. rail encl. w/o display, L-L: .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

7KM5212-6CA00-1EA8 SIEMENS SENTRON, measuring device, 7KM PAC5100, strd mount. rail encl. w/o display, L-L: ..

7KM5212-6CA00-1EA8

SIEMENS

SENTRON, measuring device, 7KM PAC5100, strd mount. rail encl. w/o display, L-L: 690 V, L-N: 400 V, 10 A, strd rail instr., 3-phase, Modbus TCP, apparent /active/reactive energy / cos phi, harmonics: 2. - 40., THD, class 0.5 acc. to IEC61557-12 or cl. 0.5S acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals

SENTRON PAC5100, DIN RAIL POWER MONITORING DEVICE PROFILE BOX FOR MEASURING ELECTRICAL VARIABLES PROTOCOL: MODBUS TCP WITHOUT DISPLAY. Cancelations and returns limited. Consult conditions.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SENTRON PAC network analyzers. Energy Management Software

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

SENTRON, measuring device, 7KM PAC5100, strd mount. rail encl. w/o display, L-L: 690 V, L-N: 400 V, 10 A, strd rail instr., 3-phase, Modbus TCP, apparent /active/reactive energy / cos phi, harmonics: 2. - 40., THD, class 0.5 acc. to IEC61557-12 or cl. 0.5S acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals
Model
product brand nameSENTRON
product designation7KM PAC5100
design of the productcompact
product type designationMeasuring instrument
Measurements
measuring procedure
● for voltage measurementTRMS
● for current measurementTRMS
type of measured value detectioncomplete
voltage curveSinusoidal or distorted
measurable line frequency
● initial value45 Hz
● full-scale value65 Hz
operating mode for measured value detection automatic line frequency detectionYes
operating mode for measured value detection
● set at 50 HzNo
● set to 60 HzNo
Supply voltage
design of the power supplyWide-range power supply
type of voltage of the supply voltageAC/DC
Degree of protection protection class
protection class IP on the frontIP20
operating resource protection class when installedsafety class II
Suitability
suitability for operationStandard mounting rail device
Product Functions
product function
● voltage measurementYes
● current measurementYes
● active power measurementYes
● reactive power measurementYes
● frequency measurementYes
Display and operation
design of the displayStandard mounting rail enclosure without display
color of the background of the displaywhite
illuminance of display backlight adjustableNo
time-controlled reduction of the illuminance of display backlight possibleNo
display contrast adjustableNo
national language on the display screen is supportedde, en
number of keys4
Communication
number of interfaces according to Fast Ethernet1
type of electrical connection of the fast Ethernet interfaceRJ45 (8P8C)
Fault limits
reference condition for metering accuracyaccording to IEC 62053-22, IEC 62053-23, IEC 62586-1, Class S, IEC 61000-4-30, IEC 61000-4-7, IEC 61000-4-15
formula for relative total measurement inaccuracy
● for measured variable voltage+/- 0,2 %
● for measured variable current+/- 0,2 %
● for measured variable output factor+/- 0,5 %
● for measured variable active energyCl. 0.5 acc. to... IEC62053-22
● for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
Inputs Outputs
number of digital inputs0
number of digital outputs2
type of switching outputsolid state
digital output versionContinuous output, pulse output
operating voltage as output voltage at DC maximum permissible250 V
type of electrical connection at the digital outputsscrew-type terminals
output current
● at digital output for signal <1> maximum300 mA
internal resistance at the digital outputs35 Ω
pulse duration
● initial value50 ms
● full-scale value3 600 000 ms
adjustable time period minimum50 ms
switching frequency at digital output maximum10 Hz
property of the output short-circuit proofYes
measuring category for digital signalsCat. III
Measuring inputs
measurable supply voltage between (PE)N and L at AC maximum rated value400 V
measurable supply voltage between the line conductors at AC maximum rated value690 V
measurable supply voltage between the line conductors at AC
● maximum831 V
voltage measuring range extension with external voltage transformersyes
line conductors and neutral conductors internal resistance for voltage measurement6 MΩ
measuring category for voltage measurementCATIII
measurable current
● 1 at AC rated value5 A
● 2 at AC rated value5 A
relative measurable current at AC
● minimum1 %
● maximum200 %
current measuring range extension with external current transformersyes
zero point suppression for current measurement0 ... 10 %
● for neutral conductor current0.0 % to 10.0 % (from Vrated, Irated)
measuring category for current measurementCATIII
Connections
type of connectable conductor cross-sections
● at the measurement inputs for voltage solid2.5 mm²
● at the measurement inputs for voltage finely stranded with core end processing2.5 mm²
● at the measurement inputs for voltage at AWG cables solidScrew connection
● at the measurement inputs for current at AWG cables solidScrew connection
type of electrical connection
● at the measurement inputs for voltagescrew-type terminals
● at the measurement inputs for currentscrew-type terminals
Mechanical Design
fastening method standard rail mountingYes
size of Power Monitoring DeviceDIN rail
net weight753 g
mounting positionvertical
Environmental conditions
ambient temperature during operation
● minimum-25 °C
● maximum55 °C
ambient temperature during storage
● minimum-40 °C
● maximum70 °C
relative humidity at 25 °C without condensation during operation maximum95 %
installation altitude at height above sea level maximum2 000 m
degree of pollution2
Certificates
certificate of suitability as EC Declaration of ConformityEN 61000-6-2 and EN 61000-6-4 for EMC guideline

Downloads and manuals

General Product ApprovalDeclaration of ConformityotherDangerous Good

Confirmation

EAC

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Miscellaneous

Dangerous Goods Information

Further information
Information- and Downloadcenter (catalogues, leaflets,...)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/12/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)7KM5212-6CA00-1EA8
Product DescriptionSENTRON, measuring device, 7KM PAC5100, strd mount. rail encl. w/o display, L-L: 690 V, L-N: 400 V, 10 A, strd rail instr., 3-phase, Modbus TCP, apparent /active/reactive energy / cos phi, harmonics: 2. - 40., THD, class 0.5 acc. to IEC61557-12 or cl. 0.5S acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals
Product familySENTRON 7KM PAC Measuring Devices
Product Lifecycle (PLM)PM400:Phase Out Started
PLM Effective DateProduct phase-out since: 14.10.2021
Notes
Sucessor:7KM5412-6CA00-1EA8 - The replacement device has more features
Price data
Region Specific PriceGroup / Headquarter Price Group15N / 1DD
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,799 Kg
Packaging Dimension140,00 x 112,00 x 155,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869524566
UPCNot available
Commodity Code90303100
LKZ_FDB/ CatalogIDLV10.1
Product Group5311
Group CodeP360
Country of originIndia
Compliance with the substance restrictions according to RoHS directiveSince: 14.05.2015
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-20-03-01
eClass7.127-20-03-01
eClass827-20-03-01
eClass927-20-03-01
eClass9.127-20-03-01
ETIM5EC002301
ETIM6EC002301
ETIM7EC002301
ETIM8EC002301
UNSPSC1441-11-37-08
UNSPSC1541-11-37-08

ETIM data

ETIM: EC002301 - Multifunction measuring instrument

Value Unit
Ampere meter (EF006555) false
Blind power meter (EF006556) false
With rotational speed meter (EF006557) false
Frequency meter (EF006558) false
Pulse counter (EF006559) false
Voltmeter (EF006560) false
Effective power measurement device (EF006561) false



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.