SIPLUS ET 200SP CPU 1512SP-1 PN -40...+60°C with conformal coating based on 6ES7512-1DK01-0AB0 . CPU 1512SP-1 PN for ET 200SP, Central processing unit with Work memory 200 KB for program and 1 MB for data, first interface: PROFINET IRT with 3-port switch, 48 ns bit performance, SIMATIC Memory Card required, BusAdapter required for port 1 and 2

SIPLUS ET 200SP -40...+60 ° C temp. boot: -25 ° C with coating formed based on 6ES7512-1DK01-0AB0 . CPU 1512SP-1 PN for ET 200SP, CPU with working memory 200 KB for program and 1 MB for data, 1. INTERFACE: PROFINET IRT with 3 port-switch, 48 ns execution instrucc. binary, necessary SIMATIC Memory Card, bus adapter required to port1 and 2

More details


AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001603 - Fieldbus, decentr. periphery - basic appliance

Value Unit
Type of electric connection (EF003961) -
Number of HW-interfaces USB (EF003025) -
Category according to EN 954-1 (EF006782) -
Max. input current DC (EF007362) -A
Number of slots (EF003077) -
Supporting protocol for TCP/IP (EF003050) -
With potential separation (EF003272) -
With integrated power supply (EF003338) -
Input voltage at AC 50 Hz (EF007118) ['-', '-']V
Input voltage at AC 60 Hz (EF007119) ['-', '-']V
Input voltage at DC (EF007120) ['19.2', '28.8']V
Type of voltage (input voltage) (EF003033) DC
Max. input current AC 50 Hz (EF007360) -A
Max. input current AC 60 Hz (EF007361) -A
Output voltage at AC 50 Hz (EF006999) ['-', '-']V
Output voltage at AC 60 Hz (EF007000) ['-', '-']V
Output voltage at DC (EF007001) ['-', '-']V
Type of output voltage (EF008222) -
Max. output current AC 50 Hz (EF007351) -A
Max. output current AC 60 Hz (EF007352) -A
Max. output current DC (EF007353) -A
Number of HW-interfaces industrial Ethernet (EF003020) 1
Number of interfaces PROFINET (EF006932) 1
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) true
Supporting protocol for PROFIBUS (EF003052) true
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) true
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for PROFINET IO (EF007525) true
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Degree of protection (IP) (EF005474) IP20
With pluggable modules, digital I/O (EF003078) true
With pluggable modules, analogue I/O (EF003079) true
With pluggable modules, communication modules (EF003080) true
With pluggable modules, function and technology modules (EF003081) true
With pluggable modules, central modules (EF003082) true
With pluggable modules, others (EF003083) true
Fieldbus connection over separate bus coupler possible (EF004002) true
With bus coupler for modular station connection (EF003990) true
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) true
Front build in possible (EF007016) -
Rack-assembly possible (EF007018) -
Suitable for safety functions (EF001597) false
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust (EF003998) None
Width (EF000008) 100.0mm
Height (EF000040) 117.0mm
Depth (EF000049) 75.0mm


SIPLUS ET 200SP CPU 1512SP-1 PN -40...+60°C with conformal coating based on 6ES7512-1DK01-0AB0 . CPU 1512SP-1 PN for ET 200SP, Central processing unit with Work memory 200 KB for program and 1 MB for data, first interface: PROFINET IRT with 3-port switch, 48 ns bit performance, SIMATIC Memory Card required, BusAdapter required for port 1 and 2
General information
Product type designationCPU 1512SP-1 PN
Product function
● Isochronous modeYes; Only with PROFINET; with minimum OB 6x cycle of 625 µs
Configuration control
via datasetYes
Control elements
Mode selector switch1
Supply voltage
Type of supply voltage24 V DC
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
● Mains/voltage failure stored energy time5 ms
Input current
Current consumption (rated value)0.6 A
Inrush current, max.4.7 A; Rated value
I²t0.14 A²·s
Power
Infeed power to the backplane bus8.75 W
Power loss
Power loss, typ.5.6 W
Memory
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
● integrated (for program)200 kbyte
● integrated (for data)1 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeYes
CPU processing times
for bit operations, typ.48 ns
for word operations, typ.58 ns
for fixed point arithmetic, typ.77 ns
for floating point arithmetic, typ.307 ns
CPU-blocks
Number of elements (total)2 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements
DB
● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range0 ... 65 535
● Size, max.200 kbyte
FC
● Number range0 ... 65 535
● Size, max.200 kbyte
OB
● Size, max.200 kbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs1
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
● Number2 048
Retentivity
— adjustableYes
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Flag
● Number, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustableYes
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules2 048; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
● Number of subprocess images, max.32
Address space per module
● Address space per module, max.32 byte; For input and output data respectively
Address space per station
● Address space per station, max.1 280 byte; for central inputs and outputs; depending on configuration
Hardware configuration
Number of distributed IO systems20
Number of DP masters
● Via CM1
Number of IO Controllers
● integrated1
● Via CM0
Rack
● Modules per rack, max.64; CPU + 64 modules + server module (mounting width max. 1 m)
● Number of lines, max.1
PtP CM
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedYes
● to DP, masterYes; Via CM DP module
● to DP, slaveYes; Via CM DP module
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces1
Number of PROFIBUS interfaces1; Via CM DP module
Optical interfaceYes; Via BusAdapter BA 2x SCRJ
1. Interface
Interface types
● Number of ports3; 1. integr. + 2. via BusAdapter
● integrated switchYes
● RJ 45 (Ethernet)Yes; X1
● BusAdapter (PROFINET)Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC
Protocols
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes
● Web serverYes
● Media redundancyYes
PROFINET IO Controller
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— MRPYes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
— MRPDYes; Requirement: IRT
— PROFIenergyYes
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.128; In total, up to 253 distributed I/O devices can be connected via PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeNo
— IRTYes
— MRPYes
— MRPDYes
— PROFIenergyYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
2. Interface
Interface types
● Number of ports1
● RS 485Yes; Via CM DP module
Protocols
● PROFIBUS DP masterYes
● PROFIBUS DP slaveYes
● SIMATIC communicationYes
Interface types
RJ 45 (Ethernet)
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
RS 485
● Transmission rate, max.12 Mbit/s
Protocols
Number of connections
● Number of connections, max.88
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces88
● Number of S7 routing paths16
Redundancy mode
Media redundancy
— MRPYes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
— Switchover time on line break, typ.200 ms
— Number of stations in the ring, max.50
SIMATIC communication
● S7 communication, as serverYes
● S7 communication, as clientYes
● User data per job, max.See online help (S7 communication, user data size)
Open IE communication
● TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
● UDPYes
— Data length, max.1 472 byte
● DHCPNo
● SNMPYes
● DCPYes
● LLDPYes
Web server
● HTTPYes; Standard and user-defined pages
● HTTPSYes; Standard and user-defined pages
PROFIBUS DP master
● Number of connections, max.48
Services
— PG/OP communicationYes
— S7 routingYes
— Data record routingYes
— Isochronous modeNo
— EquidistanceNo
— Number of DP slaves125
— Activation/deactivation of DP slavesYes
Further protocols
● MODBUSYes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000
Number of simultaneously active program alarms
● Number of program alarms300
● Number of alarms for system diagnostics100
● Number of alarms for motion technology objects80
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 3 engineering systems
Status blockYes; up to 8 simultaneously
Single stepNo
Status/control
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● ForcingYes
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
Diagnostic buffer
● presentYes
● Number of entries, max.1 000
— of which powerfail-proof500
Traces
● Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
● Monitoring of the supply voltage (PWR-LED)Yes
● Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes
● Speed-controlled axis
— Number of speed-controlled axes, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Positioning axis
— Number of positioning axes, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Synchronized axes (relative gear synchronization)
— Number of axes, max.3; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● External encoders
— Number of external encoders, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Controller
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counterYes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
● horizontal installation, max.60 °C; = Tmax
● vertical installation, min.-40 °C; = Tmin
● vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m
● Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Configuration
Programming
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— GRAPHYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionYes
● Block protectionYes
Access protection
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Complete protectionYes
Cycle time monitoring
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
Width100 mm
Height117 mm
Depth75 mm
Weights
Weight, approx.310 g
last modified:08/29/2020


Product
Article Number (Market Facing Number)6AG1512-1DK01-2AB0
Product DescriptionSIPLUS ET 200SP CPU 1512SP-1 PN -40...+60°C with conformal coating based on 6ES7512-1DK01-0AB0 . CPU 1512SP-1 PN for ET 200SP, Central processing unit with Work memory 200 KB for program and 1 MB for data, first interface: PROFINET IRT with 3-port switch, 48 ns bit performance, SIMATIC Memory Card required, BusAdapter required for port 1 and 2
Product familySIPLUS CPU 1512SP-1 PN
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group473
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99H
Standard lead time ex-works42 Day/Days
Net Weight (kg)0,500 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension10,00 x 12,20 x 6,30
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047618072322
UPC804766386046
Commodity Code85371091
LKZ_FDB/ CatalogIDA&DSE/SIP ADD
Product Group4257
Group CodeR740
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 21.07.2014
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-26-07
eClass7.127-24-26-07
eClass827-24-26-07
eClass927-24-26-07
eClass9.127-24-26-07
ETIM5EC001603
ETIM6EC001603
ETIM7EC001603
IDEA43565
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.