6AG1151-7AA21-2AB0
SIEMENS
1
SIPLUS ET 200S IM 151-7 CPU -25...+60°C with conformal coating based on 6ES7151-7AA21-0AB0 . ET 200S 128 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP slave, without battery SIMATIC MMC required
SIPLUS ET200 interface module for ET200S IM151-7 CPU, -25 ... +60 ° C with coating formed based on 6ES7151-7AA21-0AB0 . ET200S, working Memory 128 KB. Profibus DP interface (integrated Connector 9-pole sub-D) as is DP, no battery required SIMATIC MMC
AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Value | Unit | |
|---|---|---|
| Category according to EN 954-1 (EF006782) | - | |
| SIL according to IEC 61508 (EF009889) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| With integrated power supply (EF003338) | true | |
| Input voltage at AC 50 Hz (EF007118) | ['-', '-'] | V |
| Input voltage at AC 60 Hz (EF007119) | ['-', '-'] | V |
| Input voltage at DC (EF007120) | ['19.2', '28.8'] | V |
| Type of voltage (input voltage) (EF003033) | DC | |
| Max. input current AC 50 Hz (EF007360) | - | A |
| Max. input current AC 60 Hz (EF007361) | - | A |
| Max. input current DC (EF007362) | 0.32 | A |
| Output voltage at AC 50 Hz (EF006999) | ['-', '-'] | V |
| Output voltage at AC 60 Hz (EF007000) | ['-', '-'] | V |
| Output voltage at DC (EF007001) | ['-', '-'] | V |
| Type of output voltage (EF008222) | - | |
| Max. output current AC 50 Hz (EF007351) | - | A |
| Max. output current AC 60 Hz (EF007352) | - | A |
| Max. output current DC (EF007353) | - | A |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 | |
| Number of interfaces PROFINET (EF006932) | 0 | |
| Number of HW-interfaces RS-232 (EF003021) | 0 | |
| Number of HW-interfaces RS-422 (EF003022) | 0 | |
| Number of HW-interfaces RS-485 (EF003023) | 1 | |
| Number of HW-interfaces serial TTY (EF003024) | 0 | |
| Number of HW-interfaces USB (EF003025) | 0 | |
| Number of HW-interfaces parallel (EF003026) | 0 | |
| Number of HW-interfaces Wireless (EF006933) | 0 | |
| Number of HW-interfaces other (EF003027) | 0 | |
| With optical interface (EF003028) | false | |
| Supporting protocol for TCP/IP (EF003050) | false | |
| Supporting protocol for PROFIBUS (EF003052) | true | |
| Supporting protocol for CAN (EF003053) | false | |
| Supporting protocol for INTERBUS (EF003054) | false | |
| Supporting protocol for ASI (EF003051) | false | |
| Supporting protocol for KNX (EF003055) | false | |
| Supporting protocol for Modbus (EF003057) | false | |
| Supporting protocol for Data-Highway (EF003058) | false | |
| Supporting protocol for DeviceNet (EF003059) | false | |
| Supporting protocol for SUCONET (EF003060) | false | |
| Supporting protocol for LON (EF003017) | false | |
| Supporting protocol for SERCOS (EF006657) | false | |
| Supporting protocol for PROFINET IO (EF007525) | false | |
| Supporting protocol for PROFINET CBA (EF007524) | false | |
| Supporting protocol for Foundation Fieldbus (EF007522) | false | |
| Supporting protocol for EtherNet/IP (EF007521) | false | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false | |
| Supporting protocol for DeviceNet Safety (EF007520) | false | |
| Supporting protocol for INTERBUS-Safety (EF006662) | false | |
| Supporting protocol for PROFIsafe (EF007526) | false | |
| Supporting protocol for SafetyBUS p (EF007527) | false | |
| Supporting protocol for other bus systems (EF003062) | true | |
| Radio standard Bluetooth (EF007178) | false | |
| Radio standard WLAN 802.11 (EF007179) | false | |
| Radio standard GPRS (EF008523) | false | |
| Radio standard GSM (EF008524) | false | |
| Radio standard UMTS (EF008525) | false | |
| IO link master (EF007298) | false | |
| System accessory (EF004118) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Number of slots (EF003077) | 63 | |
| With pluggable modules, digital I/O (EF003078) | true | |
| With pluggable modules, analogue I/O (EF003079) | true | |
| With pluggable modules, communication modules (EF003080) | true | |
| With pluggable modules, function and technology modules (EF003081) | true | |
| With pluggable modules, central modules (EF003082) | true | |
| With pluggable modules, others (EF003083) | true | |
| Type of electric connection (EF003961) | Screw-/spring clamp connection | |
| With potential separation (EF003272) | true | |
| Fieldbus connection over separate bus coupler possible (EF004002) | true | |
| With bus coupler for modular station connection (EF003990) | true | |
| Rail mounting possible (EF003972) | true | |
| Wall mounting/direct mounting (EF007020) | true | |
| Front build in possible (EF007016) | - | |
| Rack-assembly possible (EF007018) | - | |
| Suitable for safety functions (EF001597) | false | |
| Appendant operation agent (Ex ia) (EF004141) | false | |
| Appendant operation agent (Ex ib) (EF004142) | false | |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G | |
| Explosion safety category for dust (EF003998) | None | |
| Width (EF000008) | 60.0 | mm |
| Height (EF000040) | 119.5 | mm |
| Depth (EF000049) | 75.0 | mm |
| SIPLUS ET 200S IM 151-7 CPU -25...+60°C with conformal coating based on 6ES7151-7AA21-0AB0 . ET 200S 128 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP slave, without battery SIMATIC MMC required | ||
| General information | ||
| HW functional status | 01 | |
| Firmware version | V3.3 | |
| Product function | ||
| ● Isochronous mode | No | |
| Engineering with | ||
| ● Programming package | V5.5 + SP1 or higher or V5.2 + SP1 or higher + HSP 219 | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes; against destruction | |
| external protection for power supply lines (recommendation) | 24 V DC/16 A miniature circuit breaker with type B and C tripping characteristics. Note: A 24 V DC/16 A miniature circuit breaker with type B tripping characteristics trips before and with type C tripping characteristic after the device protection fuse. | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Inrush current, max. | 1.8 A; Typical | |
| I²t | 0.09 A²·s | |
| from supply voltage 1L+, max. | 320 mA; 410 mA with DP master module | |
| Output current | ||
| for backplane bus (5 V DC), max. | 700 mA | |
| Power loss | ||
| Power loss, typ. | 4.2 W | |
| Memory | ||
| Work memory | ||
| ● integrated | 128 kbyte | |
| ● expandable | No | |
| ● Size of retentive memory for retentive data blocks | 64 kbyte | |
| Load memory | ||
| ● Plug-in (MMC) | Yes | |
| ● Plug-in (MMC), max. | 8 Mbyte | |
| ● Data management on MMC (after last programming), min. | 10 y | |
| Backup | ||
| ● present | Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free) | |
| CPU processing times | ||
| for bit operations, typ. | 0.06 µs | |
| for word operations, typ. | 0.12 µs | |
| for fixed point arithmetic, typ. | 0.16 µs | |
| for floating point arithmetic, typ. | 0.59 µs | |
| CPU-blocks | ||
| Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
| DB | ||
| ● Number, max. | 1 024; Number range: 1 to 16000 | |
| ● Size, max. | 64 kbyte | |
| FB | ||
| ● Number, max. | 1 024; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| FC | ||
| ● Number, max. | 1 024; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| OB | ||
| ● Description | See S7-300 operation list | |
| ● Size, max. | 64 kbyte | |
| ● Number of free cycle OBs | 1; OB 1 | |
| ● Number of time alarm OBs | 1; OB 10 | |
| ● Number of delay alarm OBs | 2; OB 20, 21 | |
| ● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 | |
| ● Number of process alarm OBs | 1; OB 40 | |
| ● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 | |
| ● Number of startup OBs | 1; OB 100 | |
| ● Number of asynchronous error OBs | 6; OB 80, 82, 83 (for centralized I/O only, not for distributed I/O), 85, 86, 87 | |
| ● Number of synchronous error OBs | 2; OB 121, 122 | |
| Nesting depth | ||
| ● per priority class | 16 | |
| ● additional within an error OB | 4 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 256 | |
| Retentivity | ||
| — adjustable | Yes | |
| — lower limit | 0 | |
| — upper limit | 255 | |
| — preset | Z 0 to Z 7 | |
| Counting range | ||
| — lower limit | 0 | |
| — upper limit | 999 | |
| IEC counter | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| S7 times | ||
| ● Number | 256 | |
| Retentivity | ||
| — adjustable | Yes | |
| — lower limit | 0 | |
| — upper limit | 255 | |
| — preset | No retentivity | |
| Time range | ||
| — lower limit | 10 ms | |
| — upper limit | 9 990 s | |
| IEC timer | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| Data areas and their retentivity | ||
| Flag | ||
| ● Number, max. | 256 byte | |
| ● Retentivity available | Yes; MB 0 to MB 255 | |
| ● Retentivity preset | MB 0 to MB 15 | |
| ● Number of clock memories | 8; 1 memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes; via non-retain property on DB | |
| ● Retentivity preset | Yes | |
| Local data | ||
| ● per priority class, max. | 32 kbyte; Max. 2048 bytes per block | |
| Address area | ||
| I/O address area | ||
| ● Inputs | 2 048 byte | |
| ● Outputs | 2 048 byte | |
| of which distributed | ||
| — Inputs | 2 048 byte | |
| — Outputs | 2 048 byte | |
| Process image | ||
| ● Inputs | 2 048 byte | |
| ● Outputs | 2 048 byte | |
| ● Inputs, adjustable | 2 048 byte | |
| ● Outputs, adjustable | 2 048 byte | |
| ● Inputs, default | 128 byte | |
| ● Outputs, default | 128 byte | |
| Digital channels | ||
| ● Inputs | 16 336 | |
| — of which central | 496 | |
| ● Outputs | 16 336 | |
| — of which central | 496 | |
| Analog channels | ||
| ● Inputs | 1 021 | |
| — of which central | 124 | |
| ● Outputs | 1 021 | |
| — of which central | 124 | |
| Hardware configuration | ||
| Number of modules per system, max. | 63; Centralized | |
| Mounting rail | ||
| ● Number of mounting rails that can be used | 1 | |
| ● Length of mounting rail, max. | Station width: ≤ 1 m or < 2 m | |
| Time of day | ||
| Clock | ||
| ● Hardware clock (real-time) | Yes | |
| ● retentive and synchronizable | Yes | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| ● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF | |
| ● Behavior of the clock following expiry of backup period | Clock continues to run with the time at which the power failure occurred | |
| Operating hours counter | ||
| ● Number | 1 | |
| ● Number/Number range | 0 | |
| ● Range of values | 0 to 2^31 hours (when using SFC 101) | |
| ● Granularity | 1 h | |
| ● retentive | Yes; Must be restarted at each restart | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to MPI, master | Yes | |
| ● to MPI, slave | Yes | |
| ● to DP, master | Yes; With DP slave only slave clock | |
| ● to DP, slave | Yes | |
| ● in AS, master | No | |
| ● in AS, slave | No | |
| Interfaces | ||
| Interfaces/bus type | 1 x MPI/PROFIBUS DP | |
| 1. Interface | ||
| Interface type | Integrated RS 485 interface | |
| Physics | RS 485 | |
| Isolated | Yes | |
| Power supply to interface (15 to 30 V DC), max. | 80 mA | |
| Protocols | ||
| ● MPI | Yes | |
| ● PROFIBUS DP master | No | |
| ● PROFIBUS DP slave | Yes; active / passive | |
| ● Point-to-point connection | No | |
| MPI | ||
| ● Transmission rate, max. | 12 Mbit/s | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes; With master module | |
| — Global data communication | Yes | |
| — S7 basic communication | Yes | |
| — S7 communication | Yes; Only server, configured on one side | |
| — S7 communication, as client | No | |
| — S7 communication, as server | Yes | |
| PROFIBUS DP slave | ||
| ● GSD file | The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) | |
| ● Transmission rate, max. | 12 Mbit/s | |
| ● automatic baud rate search | Yes; only with passive interface | |
| ● Address area, max. | 32 | |
| ● User data per address area, max. | 32 byte; Up to max. size of the transfer memory | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes; Only with active, integrated DP slave interface and inserted DP master module in DP master mode | |
| — Global data communication | No | |
| — S7 basic communication | No | |
| — S7 communication | Yes; Only server, configured on one side | |
| — S7 communication, as client | No | |
| — S7 communication, as server | Yes | |
| — Direct data exchange (slave-to-slave communication) | Yes | |
| — DPV1 | No | |
| Transfer memory | ||
| — Inputs | 244 byte | |
| — Outputs | 244 byte | |
| 2. Interface | ||
| Interface type | External interface via master module 6ES7138-4HA00-0AB0 | |
| Physics | RS 485 | |
| Isolated | Yes | |
| Power supply to interface (15 to 30 V DC), max. | No | |
| Protocols | ||
| ● MPI | No | |
| ● PROFIBUS DP master | Yes | |
| ● PROFIBUS DP slave | No | |
| PROFIBUS DP master | ||
| ● Transmission rate, max. | 12 Mbit/s | |
| ● Number of DP slaves, max. | 32; Per station | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes | |
| — Global data communication | No | |
| — S7 basic communication | Yes; I blocks only | |
| — S7 communication | Yes; Only server, configured on one side | |
| — S7 communication, as client | No | |
| — S7 communication, as server | Yes | |
| — Equidistance | Yes | |
| — Isochronous mode | No | |
| — SYNC/FREEZE | Yes | |
| — Activation/deactivation of DP slaves | Yes | |
| — Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 | |
| — Direct data exchange (slave-to-slave communication) | Yes | |
| — DPV1 | Yes | |
| Address area | ||
| — Inputs, max. | 2 kbyte | |
| — Outputs, max. | 2 kbyte | |
| User data per DP slave | ||
| — Inputs, max. | 244 byte | |
| — Outputs, max. | 244 byte | |
| Communication functions | ||
| PG/OP communication | Yes | |
| Data record routing | Yes; With DP master module | |
| Global data communication | ||
| ● supported | Yes | |
| ● Number of GD loops, max. | 8 | |
| ● Number of GD packets, max. | 8 | |
| ● Number of GD packets, transmitter, max. | 8 | |
| ● Number of GD packets, receiver, max. | 8 | |
| ● Size of GD packets, max. | 22 byte | |
| ● Size of GD packet (of which consistent), max. | 22 byte | |
| S7 basic communication | ||
| ● supported | Yes | |
| ● User data per job, max. | 76 byte | |
| ● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | |
| S7 communication | ||
| ● supported | Yes | |
| ● as server | Yes | |
| ● as client | No | |
| ● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
| ● User data per job (of which consistent), max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
| Number of connections | ||
| ● overall | 12 | |
| ● usable for PG communication | 11 | |
| — reserved for PG communication | 1 | |
| — adjustable for PG communication, min. | 1 | |
| — adjustable for PG communication, max. | 11 | |
| ● usable for OP communication | 11 | |
| — reserved for OP communication | 1 | |
| — adjustable for OP communication, min. | 1 | |
| — adjustable for OP communication, max. | 11 | |
| ● usable for S7 basic communication | 10 | |
| — reserved for S7 basic communication | 0 | |
| — adjustable for S7 basic communication, min. | 0 | |
| — adjustable for S7 basic communication, max. | 10 | |
| ● usable for routing | 4; As slave only with active interface, with IM 151-7 CPU as DP master | |
| S7 message functions | ||
| Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication | |
| Process diagnostic messages | Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ | |
| simultaneously active Alarm-S blocks, max. | 300 | |
| Test commissioning functions | ||
| Status block | Yes; Up to 2 simultaneously | |
| Single step | Yes | |
| Number of breakpoints | 4 | |
| Status/control | ||
| ● Status/control variable | Yes | |
| ● Variables | Inputs, outputs, memory bits, DB, times, counters | |
| ● Number of variables, max. | 30 | |
| — of which status variables, max. | 30 | |
| — of which control variables, max. | 14 | |
| Forcing | ||
| ● Forcing | Yes | |
| ● Forcing, variables | Inputs, outputs | |
| ● Number of variables, max. | 10 | |
| Diagnostic buffer | ||
| ● present | Yes | |
| ● Number of entries, max. | 500 | |
| — adjustable | No | |
| — of which powerfail-proof | 100; Only the last 100 entries are retained | |
| ● Number of entries readable in RUN, max. | 499 | |
| — adjustable | Yes; From 10 to 499 | |
| — preset | 10 | |
| Service data | ||
| ● can be read out | Yes | |
| Interrupts/diagnostics/status information | ||
| Alarms | Yes | |
| Diagnostics function | Yes | |
| Diagnostics indication LED | ||
| ● Group error SF (red) | Yes | |
| ● Monitoring 24 V voltage supply ON (green) | Yes | |
| Potential separation | ||
| between PROFIBUS DP and all other circuit components | Yes | |
| Isolation | ||
| Isolation tested with | 500 V DC | |
| Degree and class of protection | ||
| IP degree of protection | IP20 | |
| Standards, approvals, certificates | ||
| CE mark | Yes | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● min. | -25 °C; = Tmin | |
| ● max. | 60 °C; = Tmax | |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 5 000 m | |
| ● Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) | |
| Relative humidity | ||
| ● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
| Resistance | ||
| Use in stationary industrial systems | ||
| — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | |
| — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | |
| Use on ships/at sea | ||
| — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request | |
| — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * | |
| Usage in industrial process technology | ||
| — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | |
| — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | |
| Remark | ||
| — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | |
| Configuration | ||
| Configuration rules | max. 63 peripheral modules per station; station width < 1 m or < 2 m; max. 10 A per load group (power module); master interface module on right next to IM 151-7 CPU (X2 interface) | |
| Configuration software | ||
| ● STEP 7 Lite | No | |
| Programming | ||
| ● Command set | see instruction list | |
| ● Nesting levels | 8 | |
| ● System functions (SFC) | see instruction list | |
| ● System function blocks (SFB) | see instruction list | |
| Programming language | ||
| — LAD | Yes | |
| — FBD | Yes | |
| — STL | Yes | |
| — SCL | Yes; Optional | |
| — CFC | Yes; Optional | |
| — GRAPH | Yes; Optional | |
| — HiGraph® | Yes; Optional | |
| Know-how protection | ||
| ● User program protection/password protection | Yes | |
| ● Block encryption | Yes; With S7 block Privacy | |
| Cycle time monitoring | ||
| ● lower limit | 1 ms | |
| ● upper limit | 6 000 ms | |
| ● adjustable | Yes | |
| ● preset | 150 ms | |
| Dimensions | ||
| Width | 60 mm; DP master module: 35 mm | |
| Height | 119.5 mm | |
| Depth | 75 mm | |
| Weights | ||
| Weight, approx. | 200 g; DP master module: Approx. 100 g | |
| last modified: | 08/28/2020 | |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6AG1151-7AA21-2AB0 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIPLUS ET 200S IM 151-7 CPU -25...+60°C with conformal coating based on 6ES7151-7AA21-0AB0 . ET 200S 128 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP slave, without battery SIMATIC MMC required | ||||||||||||||||||||||||||||||||||||
| Product family | SIPLUS ET 200S IM 151-7 CPU | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 473 | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99H | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 27 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,250 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 8,40 x 12,70 x 8,30 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047618042400 | ||||||||||||||||||||||||||||||||||||
| UPC | 887621294069 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85389091 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | A&DSE/SIP ADD | ||||||||||||||||||||||||||||||||||||
| Product Group | 4572 | ||||||||||||||||||||||||||||||||||||
| Group Code | R740 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.09.2014 | ||||||||||||||||||||||||||||||||||||
| Product class | B: return restricted, please contact your Siemens partner/contact | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 6AG1151-7AA21-2AB0 EN_6AG1151-7AA21-2AB0.pdf | 142 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.