Product successfully added to your shopping cart
6AG1134-6HB00-2DA1
SIEMENS
1
SIPLUS ET 200SP, (-40) -25...+60°C with conformal coating based on 6ES7134-6HB00-0DA1 . Analog input module, AI 2x U/I 2-, 4-wire high Speed, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.3%
SIPLUS ET 200SP, (-40)-25 ... +60 ° C with coating formed based on 6ES7134-6HB00-0DA1. Module of analog inputs, AI 2 X U/I 2-,4-threads HIGH SPEED. Suitable for type BU A0, A1, color code CC00, channel diagnosis, 16bit, +/-0,3%
AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| SIL according to IEC 61508 (EF009889) | - | |
| Category according to EN 954-1 (EF006782) | - | |
| Type of electric connection (EF003961) | - | |
| Supply voltage AC 60 Hz (EF007533) | - | V |
| Supply voltage AC 50 Hz (EF007532) | - | V |
| Supply voltage DC (EF007534) | ['19.2', '28.8'] | V |
| Voltage type of supply voltage (EF002991) | DC | |
| Input, current (EF003204) | true | |
| Input, voltage (EF003205) | true | |
| Input, resistor (EF003206) | false | |
| Input, resistance thermometer (EF003207) | false | |
| Input, thermocouple (EF003208) | false | |
| Input signal, configurable (EF003209) | true | |
| Resolution of the analogue inputs (EF003575) | 16 | Bit |
| Output, current (EF003212) | - | |
| Output, voltage (EF003213) | - | |
| Output signal configurable (EF003214) | - | |
| Resolution of the analogue outputs (EF003577) | - | Bit |
| Number of analogue inputs (EF001994) | 2 | |
| Number of analogue outputs (EF001995) | 0 | |
| Analogue inputs configurable (EF008518) | true | |
| Analogue outputs configurable (EF008519) | - | |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 | |
| Number of interfaces PROFINET (EF006932) | 0 | |
| Number of HW-interfaces RS-232 (EF003021) | 0 | |
| Number of HW-interfaces RS-422 (EF003022) | 0 | |
| Number of HW-interfaces RS-485 (EF003023) | 0 | |
| Number of HW-interfaces serial TTY (EF003024) | 0 | |
| Number of HW-interfaces parallel (EF003026) | 0 | |
| Number of HW-interfaces Wireless (EF006933) | 0 | |
| Number of HW-interfaces USB (EF003025) | 0 | |
| Number of HW-interfaces other (EF003027) | 0 | |
| Supporting protocol for TCP/IP (EF003050) | false | |
| Supporting protocol for PROFIBUS (EF003052) | false | |
| Supporting protocol for CAN (EF003053) | false | |
| Supporting protocol for INTERBUS (EF003054) | false | |
| Supporting protocol for ASI (EF003051) | false | |
| Supporting protocol for KNX (EF003055) | false | |
| Supporting protocol for Modbus (EF003057) | false | |
| Supporting protocol for Data-Highway (EF003058) | false | |
| Supporting protocol for DeviceNet (EF003059) | false | |
| Supporting protocol for SUCONET (EF003060) | false | |
| Supporting protocol for LON (EF003017) | false | |
| Supporting protocol for PROFINET IO (EF007525) | false | |
| Supporting protocol for PROFINET CBA (EF007524) | false | |
| Supporting protocol for SERCOS (EF006657) | false | |
| Supporting protocol for Foundation Fieldbus (EF007522) | false | |
| Supporting protocol for EtherNet/IP (EF007521) | false | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false | |
| Supporting protocol for DeviceNet Safety (EF007520) | false | |
| Supporting protocol for INTERBUS-Safety (EF006662) | false | |
| Supporting protocol for PROFIsafe (EF007526) | false | |
| Supporting protocol for SafetyBUS p (EF007527) | false | |
| Supporting protocol for other bus systems (EF003062) | false | |
| Radio standard Bluetooth (EF007178) | false | |
| Radio standard WLAN 802.11 (EF007179) | false | |
| Radio standard GPRS (EF008523) | false | |
| Radio standard GSM (EF008524) | false | |
| Radio standard UMTS (EF008525) | false | |
| IO link master (EF007298) | false | |
| System accessory (EF004118) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Fieldbus connection over separate bus coupler possible (EF004002) | false | |
| Rail mounting possible (EF003972) | true | |
| Wall mounting/direct mounting (EF007020) | false | |
| Front build in possible (EF007016) | true | |
| Rack-assembly possible (EF007018) | true | |
| Suitable for safety functions (EF001597) | false | |
| Appendant operation agent (Ex ia) (EF004141) | false | |
| Appendant operation agent (Ex ib) (EF004142) | false | |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G | |
| Explosion safety category for dust (EF003998) | None | |
| Width (EF000008) | 15.0 | mm |
| Height (EF000040) | 73.0 | mm |
| Depth (EF000049) | 58.0 | mm |
| SIPLUS ET 200SP, (-40) -25...+60°C with conformal coating based on 6ES7134-6HB00-0DA1 . Analog input module, AI 2x U/I 2-, 4-wire high Speed, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.3% | ||
| General information | ||
| Product type designation | AI 2xU/I 2-/4-wire HS | |
| Firmware version | V2.0 | |
| ● FW update possible | Yes | |
| usable BaseUnits | BU type A0, A1 | |
| Color code for module-specific color identification plate | CC00 | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | Yes | |
| ● Measuring range scalable | No | |
| Engineering with | ||
| ● PROFIBUS from GSD version/GSD revision | GSD Revision 5 | |
| ● PROFINET from GSD version/GSD revision | GSDML V2.3 | |
| Operating mode | ||
| ● Oversampling | Yes; 2 channels per module | |
| ● MSI | No | |
| CiR - Configuration in RUN | ||
| Reparameterization possible in RUN | Yes | |
| Calibration possible in RUN | No | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Input current | ||
| Current consumption (rated value) | 39 mA; without sensor supply | |
| Encoder supply | ||
| 24 V encoder supply | ||
| ● 24 V | Yes | |
| ● Short-circuit protection | Yes | |
| ● Output current, max. | 20 mA; max. 50 mA per channel for a duration < 10 s | |
| Power loss | ||
| Power loss, typ. | 0.95 W; without sensor supply | |
| Address area | ||
| Address space per module | ||
| ● Address space per module, max. | 4 byte; + 1 byte for QI information (32 bytes in the oversampling operating mode) | |
| Analog inputs | ||
| Number of analog inputs | 2; Differential inputs | |
| permissible input voltage for voltage input (destruction limit), max. | 30 V | |
| permissible input current for current input (destruction limit), max. | 50 mA | |
| Cycle time (all channels), min. | 125 µs | |
| Analog input with oversampling | Yes | |
| ● Values per cycle, max. | 16 | |
| ● Resolution, min. | 50 µs | |
| Input ranges (rated values), voltages | ||
| ● 0 to +10 V | Yes; 15 bit | |
| — Input resistance (0 to 10 V) | 75 kΩ | |
| ● 1 V to 5 V | Yes; 13 bit | |
| — Input resistance (1 V to 5 V) | 75 kΩ | |
| ● -10 V to +10 V | Yes; 16 bit incl. sign | |
| — Input resistance (-10 V to +10 V) | 75 kΩ | |
| ● -5 V to +5 V | Yes; 15 bit incl. sign | |
| — Input resistance (-5 V to +5 V) | 75 kΩ | |
| Input ranges (rated values), currents | ||
| ● 0 to 20 mA | Yes; 15 bit | |
| — Input resistance (0 to 20 mA) | 130 Ω | |
| ● -20 mA to +20 mA | Yes; 16 bit incl. sign | |
| — Input resistance (-20 mA to +20 mA) | 130 Ω | |
| ● 4 mA to 20 mA | Yes; 14 bit | |
| — Input resistance (4 mA to 20 mA) | 130 Ω | |
| Cable length | ||
| ● shielded, max. | 1 000 m; 200 m for voltage measurement | |
| Analog value generation for the inputs | ||
| Measurement principle | Actual value encryption (successive approximation) | |
| Integration and conversion time/resolution per channel | ||
| ● Resolution with overrange (bit including sign), max. | 16 bit | |
| ● Interference voltage suppression for interference frequency f1 in Hz | No | |
| ● Conversion time (per channel) | 10 µs | |
| Smoothing of measured values | ||
| ● Number of smoothing levels | 7; none; 2-/4-/8-/16-/32-/64-fold | |
| ● parameterizable | Yes | |
| Encoder | ||
| Connection of signal encoders | ||
| ● for voltage measurement | Yes | |
| ● for current measurement as 2-wire transducer | Yes | |
| — Burden of 2-wire transmitter, max. | 650 Ω | |
| ● for current measurement as 4-wire transducer | Yes | |
| Errors/accuracies | ||
| Linearity error (relative to input range), (+/-) | 0.03 % | |
| Temperature error (relative to input range), (+/-) | 0.01 %/K | |
| Crosstalk between the inputs, min. | -50 dB | |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.1 % | |
| Operational error limit in overall temperature range | ||
| ● Voltage, relative to input range, (+/-) | 0.5 % | |
| ● Current, relative to input range, (+/-) | 0.5 % | |
| Basic error limit (operational limit at 25 °C) | ||
| ● Voltage, relative to input range, (+/-) | 0.2 % | |
| ● Current, relative to input range, (+/-) | 0.2 % | |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | ||
| ● Common mode voltage, max. | 35 V | |
| ● Common mode interference, min. | 90 dB | |
| Isochronous mode | ||
| Filtering and processing time (TCI), min. | 80 µs | |
| Bus cycle time (TDP), min. | 125 µs | |
| Interrupts/diagnostics/status information | ||
| Alarms | ||
| ● Diagnostic alarm | Yes | |
| ● Limit value alarm | Yes; two upper and two lower limit values in each case | |
| Diagnoses | ||
| ● Wire-break | Yes; channel-by-channel, at 4 to 20 mA only | |
| ● Short-circuit | Yes; channel-by-channel, at 1 to 5 V or for current measuring ranges short-circuit in encoder supply | |
| ● Group error | Yes | |
| ● Overflow/underflow | Yes | |
| Diagnostics indication LED | ||
| ● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | |
| ● Channel status display | Yes; green LED | |
| ● for channel diagnostics | Yes; red LED | |
| ● for module diagnostics | Yes; green/red DIAG LED | |
| Potential separation | ||
| Potential separation channels | ||
| ● between the channels | Yes | |
| ● between the channels and backplane bus | Yes | |
| ● between the channels and the power supply of the electronics | Yes | |
| Permissible potential difference | ||
| between different circuits | 75 V DC/60 V AC (base isolation) | |
| between the inputs (UCM) | 75 V DC/60 V AC | |
| Isolation | ||
| Isolation tested with | 707 V DC (type test) | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C | |
| ● horizontal installation, max. | 60 °C; = Tmax | |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 5 000 m | |
| ● Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) | |
| Relative humidity | ||
| ● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |
| Resistance | ||
| Coolants and lubricants | ||
| — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air | |
| Use in stationary industrial systems | ||
| — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | |
| — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | |
| — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Use on ships/at sea | ||
| — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request | |
| — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * | |
| — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Usage in industrial process technology | ||
| — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | |
| — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | |
| Remark | ||
| — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | |
| Conformal coating | ||
| ● Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability | |
| ● Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection | |
| ● Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life | |
| ● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A | |
| Dimensions | ||
| Width | 15 mm | |
| Height | 73 mm | |
| Depth | 58 mm | |
| Weights | ||
| Weight, approx. | 32 g | |
| last modified: | 08/29/2020 | |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6AG1134-6HB00-2DA1 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIPLUS ET 200SP, (-40) -25...+60°C with conformal coating based on 6ES7134-6HB00-0DA1 . Analog input module, AI 2x U/I 2-, 4-wire high Speed, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.3% | ||||||||||||||||||||||||||||||||||||
| Product family | SIPLUS analog inputs | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 473 | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99H | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 37 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,040 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 6,50 x 7,70 x 2,30 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047618063719 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766320491 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85389091 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | A&DSE/SIP ADD | ||||||||||||||||||||||||||||||||||||
| Product Group | 4257 | ||||||||||||||||||||||||||||||||||||
| Group Code | R740 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 31.03.2015 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 6AG1134-6HB00-2DA1 EN_6AG1134-6HB00-2DA1.pdf | 109 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.