5SY5220-6
SIEMENS
1
Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, B, 20A
Int aut univ acces 70mm 10kA 2poles B-20A. Cancelations and returns limited. Consult conditions.
POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Industrial circuit breakers from 6 kA
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product | ||||||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 5SY5220-6 | |||||||||||||||||||||||||||||||||||||||
Product Description | Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, B, 20A | |||||||||||||||||||||||||||||||||||||||
Product family | Basic Devices | |||||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
Price data | ||||||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 12A / 1AB | |||||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
Metal Factor | L-O----- | |||||||||||||||||||||||||||||||||||||||
Delivery information | ||||||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | 95 Day/Days | |||||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 0,322 Kg | |||||||||||||||||||||||||||||||||||||||
Packaging Dimension | 40,00 x 92,00 x 84,00 | |||||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
EAN | 4001869226521 | |||||||||||||||||||||||||||||||||||||||
UPC | Not available | |||||||||||||||||||||||||||||||||||||||
Commodity Code | 85362010 | |||||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | LV10.1 | |||||||||||||||||||||||||||||||||||||||
Product Group | 5504 | |||||||||||||||||||||||||||||||||||||||
Group Code | P310 | |||||||||||||||||||||||||||||||||||||||
Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2006 | |||||||||||||||||||||||||||||||||||||||
Product class | B: return restricted, please contact your Siemens partner/contact | |||||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
Classifications | ||||||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Rated insulation voltage Ui (EF001366) | - | V |
Rated impulse withstand voltage Uimp (EF011980) | - | kV |
Release characteristic (EF000889) | B | |
Number of poles (total) (EF008618) | 2 | |
Number of protected poles (EF005548) | 2P | |
Rated current (EF000227) | 20 | A |
Rated voltage (EF000228) | 400 | V |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V (EF009556) | 10.0 | kA |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V (EF009555) | 10.0 | kA |
Voltage type (EF000187) | AC/DC | |
Frequency (EF000416) | ['50.0', '50.0'] | Hz |
Current limiting class (EF002568) | 3 | |
Suitable for flush-mounted installation (EF006573) | false | |
Concurrently switching N-neutral (EF005997) | false | |
Over voltage category (EF002569) | 3 | |
Pollution degree (EF002570) | 3 | |
Additional equipment possible (EF008148) | true | |
Width in number of modular spacings (EF002950) | 2 | |
Built-in depth (EF000218) | 70.0 | mm |
Degree of protection (IP) (EF005474) | IP20 | |
Ambient temperature during operating (EF007515) | ['-25', '55'] | °C |
Connectable conductor cross section multi-wired (EF007343) | ['0.75', '35.0'] | mm² |
Connectable conductor cross section solid-core (EF007337) | ['0.75', '35.0'] | mm² |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (EF009557) | - | kA |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (EF009558) | - | kA |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
5SY5220-6 5SY5220-6 EN_5SY5220-6.pdf | 245 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.