3VA1110-6ED32-0AA0 SIEMENS circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu 70kA @ 415V 3-po.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3VA1110-6ED32-0AA0 SIEMENS circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu 70kA @ 415V 3-po..

3VA1110-6ED32-0AA0

SIEMENS

circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In nut keeper kit

AUTOMATIC SWITCH 3VA1 IEC SIZE 160 CUTTING POWER CLASS H ICU=70KA @ 415 V 3 POLES, PROTEC. TM210, FTFM, IN=100A OVERLOAD PROTECTION IR=100A FIXED ADJUSTMENT SHORT CIRCUIT PROTECTION II=10 X IN FLAT SCREW CONNECTION. Manufactured to order. Non-Cancelable Non-Returnable.

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Moulded Case Circuit Breakers 3VA SENTRON

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $659.91
Unit price: $659.91

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In nut keeper kit
Model
product brand nameSENTRON
product designationMolded case circuit breaker
Product versionLine protection
design of the overcurrent releaseTM210
protection function of the overcurrent releaseLI
number of poles3
General technical data
rated insulation voltage Ui800 V
Max. rated operational voltage Ue with DC500 V
power loss [W] / maximum25 W
Active power loss / for rated value of the current / at AC / in hot operating state / per pole8.33 W
mechanical service life (switching cycles) / typical20 000
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz9 000
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz6 300
Neutral conductors / upgradeable/retrofittableNo
ground-fault monitoring versionWithout
product function
● communication functionNo
● other measurement functionNo
Net Weight991 g
Current
Max. rated operational current of the frame size160 A
Courant permanent assigné Iu100 A
operational current
● at 40 °C100 A
● at 45 °C100 A
● at 50 °C100 A
● at 55 °C98 A
● at 60 °C96 A
● at 65 °C94 A
● at 70 °C91 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breakerH
breaking capacity maximum short-circuit current (Icu)
● at 240 V100 kA
● at 415 V70 kA
● at 440 V55 kA
● at 500 V10 kA
● at 690 V10 kA
breaking capacity operating short-circuit current (Ics)
● at 240 V100 kA
● at 415 V70 kA
● at 440 V40 kA
● at 500 V5 kA
● at 690 V5 kA
short-circuit current making capacity (Icm)
● at 240 V220 kA
● at 415 V154 kA
● at 440 V121 kA
● at 500 V17 kA
● at 690 V17 kA
design of short-circuit protectionFor switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter
Adjustable parameters
Adjustable response value current / li min.1 000 A
Adjustable response value current / li max.1 000 A
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Mechanical Design
height [in]5.12 in
Height130 mm
width [in]3 in
Width76.2 mm
depth [in]2.76 in
depth70 mm
Connections
arrangement of electrical connectors / for main current circuitFront terminal
type of electrical connection / for main current circuitnut keeper kit on both ends
Type of connectable conductor cross-section, connection screw, width x thickness , min.12 x 1 mm
Type of connectable conductor cross-section, connection screw, width x thickness , max.17 x 6.5 mm
design of the surface / of the connections / on the top of the switch (N, 1, 3, 5)Silver
design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6)Tin
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
Accessories
product extension / optional / motor driveYes
Environmental conditions
protection class IP / on the frontIP40
ambient temperature
● during operation / minimum-25 °C
● during operation / maximum70 °C
● during storage / minimum-40 °C
● during storage / maximum80 °C
Certificates
reference code / according to IEC 81346-2Q

Downloads and manuals

General Product ApprovalEMC

Confirmation

CCC

VDE

Miscellaneous

EAC

RCM

Declaration of ConformityTest CertificatesMarine / Shipping

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Special Test Certificate

Type Test Certificates/Test Report

Miscellaneous

ABS (American Bureau of Shipping)

Marine / Shippingother

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

RMRS / Russian Maritime Register

CCS / China Classification Society

Miscellaneous

other

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
last modified:10/3/2021
Date
5/6/2022


Additional data

Product
Article Number (Market Facing Number)3VA1110-6ED32-0AA0
Product Descriptioncircuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In nut keeper kit
Product family3VA Molded Case Circuit Breakers up to 1600 A, IEC
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
Surcharge for Raw MaterialsNone
Metal FactorLOA-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works5 Day/Days
Net Weight (kg)0,991 Kg
Packaging Dimension95,00 x 150,00 x 125,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4042948812785
UPC804766430039
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10.1
Product Group5375
Group CodeP360
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.04.2014
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-04-09
eClass7.127-37-04-09
eClass827-37-04-09
eClass927-37-04-09
eClass9.127-37-04-09
ETIM5EC000228
ETIM6EC000228
ETIM7EC000228
ETIM8EC000228
IDEA44850
UNSPSC1539-12-16-01

ETIM data

ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection

Value Unit
Rated permanent current Iu (EF001389) 100.0A
Rated voltage (EF003977) ['690', '690']V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 70.0kA
Overload release current setting (EF002336) ['100', '100']A
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']A
Adjustment range undelayed short-circuit release (EF007131) ['1000', '1000']A
Integrated earth fault protection (EF007296) false
Type of electrical connection of main circuit (EF006819) Screw connection
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) true
DIN rail (top hat rail) mounting optional (EF008904) true
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) -
With under voltage release (EF007518) -
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Front side
Type of control element (EF006976) Rocker lever
Complete device with protection unit (EF008906) true
Motor drive integrated (EF006697) false
Motor drive optional (EF007386) true
Degree of protection (IP) (EF005474) IP40


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.