3TK2810-0BA01 SIEMENS SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw termina.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3TK2810-0BA01 SIEMENS SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw termina..

3TK2810-0BA01

SIEMENS

SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3

More details


Relays > Device for monitoring of safety-related circuits

CONTROL AND CONTACTORS > Limit Switches and safety relays

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $838.11
Unit price: $838.11

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
product brand nameSIRIUS
product designationStandstill monitor
design of the productfor safe stoppage monitoring
General technical data
protection class IP of the enclosureIP20
protection class IP of the terminalIP20
touch protection against electrical shockfinger-safe
insulation voltage rated value690 V
ambient temperature
● during storage-40 ... +75 °C
● during operation-25 ... +60 °C
air pressure according to SN 3120590 ... 106 kPa
relative humidity during operation10 ... 95 %
installation altitude at height above sea level maximum2 000 m
vibration resistance according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
shock resistance8g / 10 ms
surge voltage resistance rated value6 000 V
EMC emitted interferenceIEC 61000-6-2, IEC 61000-6-3
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750KT
reference code according to EN 61346-2F
number of sensor inputs
● 1-channel or 2-channel1
design of the cascadingnone
type of the safety-related wiring of the inputsmeasuring inputs
product feature cross-circuit-proofNo
Safety Integrity Level (SIL)
● according to IEC 615083
● according to IEC 620613
● for delayed release circuit according to IEC 61508SIL3
SIL Claim Limit (subsystem) according to EN 620613
performance level (PL)
● according to ISO 13849-1e
category according to EN ISO 13849-14
hardware fault tolerance according to IEC 615081
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to EN 620610.0000000015 1/h
Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 615080.002 1/y
T1 value for proof test interval or service life according to IEC 6150820 y
number of outputs as contact-affected switching element
● as NC contact
— for signaling function instantaneous contact2
● as NO contact
— safety-related instantaneous contact4
— safety-related delayed switching0
number of outputs as contact-less semiconductor switching element
● safety-related
— delayed switching0
— instantaneous contact0
● for signaling function
— delayed switching0
— instantaneous contact2
stop category according to EN 60204-10
Inputs
design of input
● cascading input/functional switchingNo
● feedback inputYes
● start inputNo
voltage measuring range at the measurement inputs at AC
● according to UL maximum600 V
● maximum690 V
input resistance at the measurement inputs500 kΩ
adjustable response value voltage for standstill detection20 ... 400 mV
Outputs
type of electrical connection plug-in socketYes
operating frequency maximum1 200 1/h
switching capacity current
● of semiconductor outputs
— for signaling function at DC-13 at 24 V0.1 A
● of the NO contacts of the relay outputs at DC-13
— at 24 V2 A
● of the NO contacts of the relay outputs at AC-15
— at 115 V3 A
— at 230 V3 A
● of the NC contacts of the relay outputs at DC-13
— at 24 V2 A
● of the NC contacts of the relay outputs at AC-15
— at 115 V2 A
— at 230 V2 A
thermal current of the switching element with contacts maximum5 A
electrical endurance (switching cycles) typical200 000
mechanical service life (switching cycles) typical50 000 000
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredquick: 5 A
Times
adjustable downtime0.2 ... 6 s
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage 1
● at DC rated value24 V
operating range factor control supply voltage rated value of magnet coil
● at DC0.9 ... 1.2
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting
width45 mm
height138.5 mm
depth120 mm
Connections/ Terminals
type of electrical connectionscrew-type terminals
type of connectable conductor cross-sections
● solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded
— with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG cables
● solid2x (20 ... 14)
● stranded2x (20 ... 14)
Product Function
product function
● light barrier monitoringNo
● standstill monitoringYes
● protective door monitoringNo
● automatic startNo
● magnetically operated switch monitoring NC-NONo
● rotation speed monitoringNo
● laser scanner monitoringNo
● monitored start-upNo
● light array monitoringNo
● magnetically operated switch monitoring NC-NCNo
● EMERGENCY OFF functionNo
● pressure-sensitive mat monitoringNo
suitability for interaction press controlNo
suitability for use
● safety switchYes
● position switch monitoringNo
● EMERGENCY-OFF circuit monitoringNo
● valve monitoringNo
● tactile sensor monitoringNo
● magnetically operated switch monitoringNo
● safety-related circuitsYes
Certificates/ approvals
certificate of suitabilityUL, CSA, EN 60204-1, EN ISO 12100, EN 954-1, IEC 61508
● TÜV (German technical inspectorate) certificateYes
● UL approvalYes
● BG BIA approvalYes

Downloads and manuals

General Product ApprovalFunctional Safety/Safety of MachineryDeclaration of Conformity

CSA

CCC

UL

EAC

Type Examination Certificate

EC/EU-Declaration of Conformity

Test CertificatesotherRailway

Special Test Certificate

Confirmation

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:4/1/2022
Date
5/6/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3TK2810-0BA01
Product DescriptionSIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
Product familyWith special functions
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41L / 41L
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)0,397 Kg
Packaging Dimension112,00 x 127,00 x 55,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209717367
UPC754554946405
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5837
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-18-19
eClass7.127-37-18-19
eClass827-37-18-19
eClass927-37-18-19
eClass9.127-37-18-19
ETIM5EC001449
ETIM6EC001449
ETIM7EC001449
ETIM8EC001449
IDEA45166
UNSPSC1439-12-15-21
UNSPSC1539-12-22-05

ETIM data

ETIM: EC001449 - Device for monitoring of safety-related circuits

Value Unit
Model (EF000010) Other
Suitable for monitoring of position switches (EF007270) false
Suitable for monitoring of emergency-stop circuits (EF007268) false
Suitable for monitoring of valves (EF007272) false
Suitable for monitoring of optoelectronic protection equipment (EF007269) false
Suitable for monitoring of tactile sensors (EF007271) false
Suitable for monitoring of magnetic switches (EF007266) false
Suitable for monitoring of proximity switches (EF007267) false
Type of electric connection (EF003961) Screw connection
Rail mounting possible (EF003972) FALSE
Rated control supply voltage Us at AC 50HZ (EF003978) ['-', '-']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['-', '-']V
Rated control supply voltage Us at DC (EF003980) ['-', '24']V
Voltage type for actuating (EF008242) DC
With detachable clamps (EF003340) true
Evaluation inputs (EF008245) Other
With start input (EF003342) false
With muting function (EF004057) false
With feedback circuit (EF003343) true
Release-delay (EF001129) ['0.2', '6.0']s
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 2
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Category according to EN 954-1 (EF006782) 4
Type of safety according to IEC 61496-1 (EF004105) -
Stop category according to IEC 60204 (EF007498) 0
Performance level according to EN ISO 13849-1 (EF007399) Level e
SIL according to IEC 61508 (EF009889) 3
With approval for TÜV (EF004144) true
With approval for BG BIA (EF004145) true
With approval according to UL (EF001783) true
Width (EF000008) 45.0mm
Height (EF000040) 138.5mm
Depth (EF000049) 120.0mm
Number of outputs, safety related, undelayed, with contact (EF003344) -
Number of outputs, safety related, delayed, with contact (EF003345) -
Number of outputs, signalling function, undelayed, with contact (EF003348) -
Number of outputs, signalling function, delayed, with contact (EF003349) -


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.