3RT1317-1BB40 SIEMENS CONTACTOR, AC-1, 14.5 KW/400V, AC-1 22 A, DC 24 V 4-POLE, 4 NO, SIZE S00, SCREW CONNE.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RT1317-1BB40 SIEMENS CONTACTOR, AC-1, 14.5 KW/400V, AC-1 22 A, DC 24 V 4-POLE, 4 NO, SIZE S00, SCREW CONNE..

3RT1317-1BB40

SIEMENS

Contactor, AC-1, 14.5 kW / 400 V AC-1, 22 A, 24 V DC 4-pole, 4 NO Size S00 Screw terminal !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2317-1BB40<<

More details


CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: 3RT2317-1BB40 3RT2317-1BB40

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



product brand name SIRIUS
Product designation power contactor
General technical data:
Size of contactor S00
Degree of pollution 3
Protection class IP
● on the front IP20
● of the terminal IP20
Mechanical service life (switching cycles)
● of contactor typical 30 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000
● of the contactor with added auxiliary switch block typical 10 000 000
Ambient conditions:
Installation altitude at height above sea level maximum 2 000 m
Ambient temperature
● during operation -25 ... +60 °C
Main circuit:
Number of NO contacts for main contacts 4
Number of NC contacts for main contacts 0
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value 22 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value 22 A
— up to 690 V at ambient temperature 60 °C rated value 20 A
● at AC-3
— at 400 V rated value 12 A
Operating current
● at 1 current path at DC-1
— at 24 V rated value 22 A
— at 110 V rated value 2.1 A
● with 2 current paths in series at DC-1
— at 24 V rated value 22 A
— at 110 V rated value 12 A
● with 3 current paths in series at DC-1
— at 24 V rated value 22 A
— at 110 V rated value 22 A
Operating current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value 20 A
— at 110 V rated value 0.15 A
● with 2 current paths in series at DC-3 at DC-5
— at 110 V rated value 0.35 A
— at 24 V rated value 20 A
● with 3 current paths in series at DC-3 at DC-5
— at 110 V rated value 20 A
— at 24 V rated value 20 A
Operating power
● at AC-1
— at 400 V rated value 14.5 kW
● at AC-2 at 400 V rated value 5.5 kW
● at AC-3
— at 400 V rated value 5.5 kW
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor 1.24 W
Control circuit/ Control:
Type of voltage of the control supply voltage DC
Control supply voltage at DC
● rated value 24 V
Operating range factor control supply voltage rated value of magnet coil at DC 0.85 ... 1.1
Closing power of magnet coil at DC 3.3 W
Holding power of magnet coil at DC 3.3 W
Auxiliary circuit:
Number of NC contacts
● for auxiliary contacts
— instantaneous contact 0
Number of NO contacts
● for auxiliary contacts
— instantaneous contact 0
Operating current at AC-12 maximum 10 A
Operating current at AC-15
● at 230 V rated value 6 A
● at 400 V rated value 3 A
Operating current at DC-12
● at 60 V rated value 6 A
● at 110 V rated value 3 A
● at 220 V rated value 1 A
Operating current at DC-13
● at 24 V rated value 10 A
● at 60 V rated value 2 A
● at 110 V rated value 1 A
● at 220 V rated value 0.3 A
Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required fuse gL/gG: 35 A
— with type of assignment 2 required fuse gL/gG: 20 A
● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A
Installation/ mounting/ dimensions:
Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
● Side-by-side mounting Yes
Height 57.5 mm
Width 45 mm
Depth 72 mm
Required spacing
● for grounded parts
— at the side 6 mm
Connections/Terminals:
Type of electrical connection
● for main current circuit screw-type terminals
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● for main contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for main contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12
Type of connectable conductor cross-sections
● for auxiliary contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.