3RS1700-2AD08-0AC0 SIEMENS INTERFACE CONVERTER AC/DC 24 V, 2 WAY SEPARATION ON: 0 TO 10 V OFF: 0 TO 10 V CAG.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RS1700-2AD08-0AC0 SIEMENS INTERFACE CONVERTER AC/DC 24 V, 2 WAY SEPARATION ON: 0 TO 10 V OFF: 0 TO 10 V CAG..

3RS1700-2AD08-0AC0

SIEMENS

INTERFACE CONVERTER AC/DC 24 V, 2 WAY SEPARATION ON: 0 TO 10 V OFF: 0 TO 10 V CAGE CLAMP PAINTED PCB

More details


CONTROL AND CONTACTORS > Function relays

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General technical data:
product brand nameSIRIUS
Product designationsingle interface converter
Design of the base unitactive
Number of channels1
Ambient temperature
● during operation°C-25 ... +60
● during transport°C-40 ... +85
● during storage°C-40 ... +85
Insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 2 rated valueV50
Consumed active powerW0.3
Protection class IPIP20
Vibration resistance acc. to IEC 60068-2-610 ... 55 Hz: 0.35 mm
Shock resistance acc. to IEC 60068-2-2715g / 11 ms
Equipment marking acc. to DIN EN 61346-2K
Equipment marking acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Connections/ Terminals:
Type of electrical connectionspring-loaded terminals
Type of connectable conductor cross-sections
● solid1x (0.5 ... 2.5 mm²)
● finely stranded with core end processing2x (0.5 ... 2.5 mm²)
● at AWG conductors
— stranded1x (20 ... 14)
Galvanic isolation:
Design of the electrical isolation2 paths
Galvanic isolation
● between entrance and outletYes
● between the voltage supply and other circuitsNo
Supply voltage:
Type of voltageAC/DC
Supply voltage frequency rated valueHz50 ... 60
Supply voltage
● at AC
— at 50 Hz rated valueV24 ... 24
— at 60 Hz rated valueV24 ... 24
● at DC rated valueV24 ... 24
Operating range factor supply voltage rated value
● at AC
— at 50 Hz0.8 ... 1.2
— at 60 Hz0.8 ... 1.2
● at DC0.7 ... 1.25
Inputs:
Limit frequencyHz30
Input voltage maximumV30
Input voltage typicalV24
Outputs:
Load at voltage output maximumkΩ1
Property of the output Short-circuit proofYes
Overvoltage strength at the current output maximumV30
Type of signal
● at output0 ... 10 V
● at input0 ... 10 V
Precision:
Relative metering precision%0.1
Relative linearity deviation%0.02
Temperature drift per °C%/°C0.015
Rise timems10
Settling time for 1 % deviationms30
Voltage ripple maximummV5
Installation/ mounting/ dimensions:
Mounting typesnap-on mounting on 35 mm DIN rail according to DIN EN 50022
Mounting positionany
Heightmm80
Widthmm6.2
Depthmm84
Certificates/ approvals:
General Product ApprovalDeclaration of Conformityother
UmweltbestätigungBestätigungen

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.