3RK3242-1AA10 SIEMENS SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RK3242-1AA10 SIEMENS SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can..

3RK3242-1AA10

SIEMENS

SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can be parameterized via MSS ES 22.5 mm overall width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable

More details


Relays > Device for monitoring of safety-related circuits

CONTROL AND CONTACTORS > Programmable safety relays MSS

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can be parameterized via MSS ES 22.5 mm overall width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable
General technical data
product brand nameSIRIUS
product categoryModular Safety System
product designationExpansion module
design of the product4 F-DO
protection class IPIP20
shock resistance15g / 11 ms
degree of pollution3
mounting positionvertical
installation altitude at height above sea level maximumm2 000
ambient temperature
● during storage°C-40 ... +85
● during operation°C-20 ... +60
● during transport°C-40 ... +85
relative humidity during operation%10 ... 95
conducted interference due to burst according to IEC 61000-4-42 kV (power ports)
conducted interference due to conductor-earth surge according to IEC 61000-4-52 kV
conducted interference due to conductor-conductor surge according to IEC 61000-4-51 kV
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
field-based interference according to IEC 61000-4-310 V/m, 3 V/m, 1 V/m
surge voltage resistance rated valueV500
insulation voltage rated valueV50
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750K
reference code according to EN 61346-2K
product function
● EMERGENCY OFF functionNo
● protective door monitoringNo
● evaluation: electro-sensitive protective equipmentNo
● evaluation: selector switchNo
● pressure-sensitive mat monitoringNo
● evaluation: two-hand operator panelNo
● evaluation: enabling switchNo
● monitored start-upNo
Control circuit/ Control
type of voltageDC
control supply voltage 1 at DC rated valueV24
operating range factor control supply voltage rated value of magnet coil0.85 ... 1.15
Auxiliary circuit
product function
● parameterizable outputsYes
number of inputs
● safety-related0
● non-safety-related0
number of outputs
● as contact-affected switching element safety-related
— single channel0
— 2-channel0
● as contact-less semiconductor switching element
— safety-related 2-channel4
— non-safety-related 2-channel0
● for testing contact-based sensors0
switching capacity current of semiconductor outputs at DC-13 at 24 VA2
Installation/ mounting/ dimensions
fastening methodstandard rail
widthmm22.5
heightmm102
depthmm124
Connections/ Terminals
type of electrical connectionscrew-type terminals
connectable conductor cross-section for auxiliary contacts
● solid or strandedmm²0.5 ... 4
● finely stranded
— with core end processingmm²0.5 ... 2.5
Certificates/ approvals
General Product ApprovalEMCFunctional Safety/Safety of Machinery

CSA

Confirmation

UL

EAC

RCM

Type Examination Certificate

Functional Safety/Safety of MachineryDeclaration of ConformityTest Certificatesother

Miscellaneous

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

Confirmation

Safety related data
Safety Integrity Level (SIL) according to IEC 615083
performance level (PL) according to EN ISO 13849-1e
category according to EN 954-14
PFHD with high demand rate according to EN 620611/h0.0000000032
Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 615081/y0.000022
T1 value for proof test interval or service life according to IEC 61508y20

Downloads and manuals

touch protection against electrical shockfinger-safe
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:12/21/2020
Date
5/10/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RK3242-1AA10
Product DescriptionSIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can be parameterized via MSS ES 22.5 mm overall width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable
Product family3RK32, 3RK33 expansion modules
Product Lifecycle (PLM)PM400:Phase Out Started
PLM Effective DateProduct phase-out since: 01.10.2021
Notes
Sucessor:successor 3SK2, S7-1200F or ET200SP when AS-i is used
Price data
Region Specific PriceGroup / Headquarter Price Group42B / 42B
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,169 Kg
Packaging Dimension28,00 x 108,50 x 147,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209793194
UPC754554971605
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group5358
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-18-19
eClass7.127-37-18-19
eClass827-37-18-19
eClass927-37-18-19
eClass9.127-37-18-19
ETIM5EC001449
ETIM6EC001449
ETIM7EC001449
ETIM8EC001449
IDEA45166
UNSPSC1439-12-15-21
UNSPSC1539-12-22-05

ETIM data

ETIM: EC001449 - Device for monitoring of safety-related circuits

Value Unit
Evaluation inputs (EF008245) -
Release-delay (EF001129) -s
Performance level according to EN ISO 13849-1 (EF007399) -
Model (EF000010) -
Suitable for monitoring of position switches (EF007270) false
Suitable for monitoring of emergency-stop circuits (EF007268) false
Suitable for monitoring of valves (EF007272) false
Suitable for monitoring of optoelectronic protection equipment (EF007269) false
Suitable for monitoring of tactile sensors (EF007271) false
Suitable for monitoring of magnetic switches (EF007266) false
Suitable for monitoring of proximity switches (EF007267) false
Type of electric connection (EF003961) Screw connection
Rail mounting possible (EF003972) FALSE
Rated control supply voltage Us at AC 50HZ (EF003978) ['-', '-']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['-', '-']V
Rated control supply voltage Us at DC (EF003980) ['24', '24']V
Voltage type for actuating (EF008242) DC
With detachable clamps (EF003340) true
With start input (EF003342) -
With muting function (EF004057) false
With feedback circuit (EF003343) -
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) -
Number of outputs, safety related, undelayed, semiconductors (EF003346) 4
Number of outputs, safety related, delayed, semiconductors (EF003347) -
Number of outputs, signalling function, undelayed, with contact (EF003348) -
Number of outputs, signalling function, delayed, with contact (EF003349) -
Number of outputs, signalling function, undelayed, semiconductors (EF003350) -
Number of outputs, signalling function, delayed, semiconductors (EF003351) -
Category according to EN 954-1 (EF006782) 4
Type of safety according to IEC 61496-1 (EF004105) -
Stop category according to IEC 60204 (EF007498) Other
SIL according to IEC 61508 (EF009889) 3
With approval for TÜV (EF004144) true
With approval for BG BIA (EF004145) -
With approval according to UL (EF001783) true
Width (EF000008) 22.5mm
Height (EF000040) 102.0mm
Depth (EF000049) 124.0mm


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.