Product successfully added to your shopping cart
3RA2115-1AE15-1FB4
SIEMENS
1
Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 1.10...1.60 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO (contactor) with diode (integrated)
FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S00 1.10...1.60 TO 24 V DC SPRING-TYPE TERMINALS FOR STANDARD RAIL MOUNTING, (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO (CONTACTOR) WITH DIODE (INTEGRATED). Manufactured to order. Non-Cancelable Non-Returnable.
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 1.10...1.60 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO (contactor) with diode (integrated) | ||||||||||||||||||||||||||||||||||||||
product brand name | SIRIUS | |||||||||||||||||||||||||||||||||||||
product designation | Direct (on-line) starter | |||||||||||||||||||||||||||||||||||||
design of the product | for standard rail or screw mounting | |||||||||||||||||||||||||||||||||||||
product type designation | 3RA21 | |||||||||||||||||||||||||||||||||||||
manufacturer's article number | ||||||||||||||||||||||||||||||||||||||
● of the supplied contactor | 3RT2015-2FB41 | |||||||||||||||||||||||||||||||||||||
● of the supplied circuit-breakers | 3RV2011-1AA25 | |||||||||||||||||||||||||||||||||||||
● of the supplied link module | 3RA2911-2AA00 | |||||||||||||||||||||||||||||||||||||
General technical data | ||||||||||||||||||||||||||||||||||||||
size of the circuit-breaker | S00 | |||||||||||||||||||||||||||||||||||||
size of load feeder | S00 | |||||||||||||||||||||||||||||||||||||
power loss [W] for rated value of the current | ||||||||||||||||||||||||||||||||||||||
● at AC in hot operating state per pole | 2.6 W | |||||||||||||||||||||||||||||||||||||
● without load current share typical | 4 W | |||||||||||||||||||||||||||||||||||||
insulation voltage with degree of pollution 3 at AC rated value | 690 V | |||||||||||||||||||||||||||||||||||||
surge voltage resistance rated value | 6 kV | |||||||||||||||||||||||||||||||||||||
degree of protection NEMA rating | other | |||||||||||||||||||||||||||||||||||||
shock resistance according to IEC 60068-2-27 | 6g / 11 ms | |||||||||||||||||||||||||||||||||||||
mechanical service life (operating cycles) of contactor typical | 30 000 000 | |||||||||||||||||||||||||||||||||||||
type of assignment | 2 | |||||||||||||||||||||||||||||||||||||
type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD | |||||||||||||||||||||||||||||||||||||
certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 | |||||||||||||||||||||||||||||||||||||
reference code according to IEC 81346-2:2019 | Q | |||||||||||||||||||||||||||||||||||||
Ambient conditions | ||||||||||||||||||||||||||||||||||||||
ambient temperature | ||||||||||||||||||||||||||||||||||||||
● during operation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||
● during storage | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||
● during transport | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||
temperature compensation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||
relative humidity during operation | 10 ... 95 % | |||||||||||||||||||||||||||||||||||||
Main circuit | ||||||||||||||||||||||||||||||||||||||
number of poles for main current circuit | 3 | |||||||||||||||||||||||||||||||||||||
design of the switching contact | electromechanical | |||||||||||||||||||||||||||||||||||||
adjustable current response value current of the current-dependent overload release | 1.1 ... 1.6 A | |||||||||||||||||||||||||||||||||||||
operating voltage | ||||||||||||||||||||||||||||||||||||||
● rated value | 690 V | |||||||||||||||||||||||||||||||||||||
● at AC-3 rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||
● at AC-3e rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||
operating frequency rated value | 50 ... 60 Hz | |||||||||||||||||||||||||||||||||||||
operational current | ||||||||||||||||||||||||||||||||||||||
● at AC-3 at 400 V rated value | 1.6 A | |||||||||||||||||||||||||||||||||||||
● at AC-3e at 400 V rated value | 1.6 A | |||||||||||||||||||||||||||||||||||||
operating power | ||||||||||||||||||||||||||||||||||||||
● at AC-3 | ||||||||||||||||||||||||||||||||||||||
— at 400 V rated value | 550 W | |||||||||||||||||||||||||||||||||||||
● at AC-3e | ||||||||||||||||||||||||||||||||||||||
— at 400 V rated value | 550 kW | |||||||||||||||||||||||||||||||||||||
Control circuit/ Control | ||||||||||||||||||||||||||||||||||||||
type of voltage of the control supply voltage | DC | |||||||||||||||||||||||||||||||||||||
control supply voltage at DC | ||||||||||||||||||||||||||||||||||||||
● rated value | 24 V | |||||||||||||||||||||||||||||||||||||
● rated value | 24 ... 24 V | |||||||||||||||||||||||||||||||||||||
holding power of magnet coil at DC | 4 W | |||||||||||||||||||||||||||||||||||||
Auxiliary circuit | ||||||||||||||||||||||||||||||||||||||
product extension auxiliary switch | Yes | |||||||||||||||||||||||||||||||||||||
number of NC contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||||||||||||||
number of NO contacts for auxiliary contacts | 1 | |||||||||||||||||||||||||||||||||||||
Protective and monitoring functions | ||||||||||||||||||||||||||||||||||||||
trip class | CLASS 10 | |||||||||||||||||||||||||||||||||||||
design of the overload release | thermal (bimetallic) | |||||||||||||||||||||||||||||||||||||
response value current of instantaneous short-circuit trip unit | 21 A | |||||||||||||||||||||||||||||||||||||
UL/CSA ratings | ||||||||||||||||||||||||||||||||||||||
full-load current (FLA) for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
● at 480 V rated value | 1.6 A | |||||||||||||||||||||||||||||||||||||
● at 600 V rated value | 1.6 A | |||||||||||||||||||||||||||||||||||||
yielded mechanical performance [hp] | ||||||||||||||||||||||||||||||||||||||
● for single-phase AC motor | ||||||||||||||||||||||||||||||||||||||
— at 230 V rated value | 0.1 hp | |||||||||||||||||||||||||||||||||||||
● for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
— at 220/230 V rated value | 0.5 hp | |||||||||||||||||||||||||||||||||||||
— at 460/480 V rated value | 1 hp | |||||||||||||||||||||||||||||||||||||
— at 575/600 V rated value | 1 hp | |||||||||||||||||||||||||||||||||||||
Short-circuit protection | ||||||||||||||||||||||||||||||||||||||
product function short circuit protection | Yes | |||||||||||||||||||||||||||||||||||||
design of the short-circuit trip | magnetic | |||||||||||||||||||||||||||||||||||||
conditional short-circuit current (Iq) | ||||||||||||||||||||||||||||||||||||||
● at 400 V according to IEC 60947-4-1 rated value | 150 000 A | |||||||||||||||||||||||||||||||||||||
Installation/ mounting/ dimensions | ||||||||||||||||||||||||||||||||||||||
mounting position | vertical | |||||||||||||||||||||||||||||||||||||
fastening method | screw and snap-on mounting onto 35 mm DIN rail | |||||||||||||||||||||||||||||||||||||
height | 198 mm | |||||||||||||||||||||||||||||||||||||
width | 45 mm | |||||||||||||||||||||||||||||||||||||
depth | 97 mm | |||||||||||||||||||||||||||||||||||||
required spacing | ||||||||||||||||||||||||||||||||||||||
● for grounded parts | ||||||||||||||||||||||||||||||||||||||
— forwards | 20 mm | |||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
— upwards | 50 mm | |||||||||||||||||||||||||||||||||||||
— at the side | 20 mm | |||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||
● for live parts | ||||||||||||||||||||||||||||||||||||||
— forwards | 20 mm | |||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
— upwards | 50 mm | |||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— at the side | 20 mm | |||||||||||||||||||||||||||||||||||||
Connections/ Terminals | ||||||||||||||||||||||||||||||||||||||
type of electrical connection | ||||||||||||||||||||||||||||||||||||||
● for main current circuit | spring-loaded terminals | |||||||||||||||||||||||||||||||||||||
● for auxiliary and control circuit | spring-loaded terminals | |||||||||||||||||||||||||||||||||||||
Safety related data | ||||||||||||||||||||||||||||||||||||||
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |||||||||||||||||||||||||||||||||||||
Communication/ Protocol | ||||||||||||||||||||||||||||||||||||||
protocol is supported | ||||||||||||||||||||||||||||||||||||||
● PROFINET IO protocol | No | |||||||||||||||||||||||||||||||||||||
● PROFIsafe protocol | No | |||||||||||||||||||||||||||||||||||||
protocol is supported AS-Interface protocol | No | |||||||||||||||||||||||||||||||||||||
Certificates/ approvals | ||||||||||||||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
Further information | ||||||||||||||||||||||||||||||||||||||
Siemens has decided to exit the Russian market (see here). | ||||||||||||||||||||||||||||||||||||||
Siemens is working on the renewal of the current EAC certificates. Please contact your local Siemens office on the status of validity of the EAC certification if you intend to import or offer to supply these products to an EAC relevant market (other than the sanctioned EAEU member states Russia or Belarus). | ||||||||||||||||||||||||||||||||||||||
Information on the packaging | ||||||||||||||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||||||||||||||
last modified: | 4/17/2023 | |||||||||||||||||||||||||||||||||||||
Date 6/29/2023 | Subject to change without notice © Copyright Siemens 2023 |
Product | ||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RA2115-1AE15-1FB4 | |||||||||||||||||||||||||||||||||
Product Description | Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 1.10...1.60 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO (contactor) with diode (integrated) | |||||||||||||||||||||||||||||||||
Product family | SIRIUS 3RA2 load feeders | |||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
Price data | ||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | |||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
Metal Factor | LCO----- | |||||||||||||||||||||||||||||||||
Delivery information | ||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
Standard lead time ex-works | 60 Day/Days | |||||||||||||||||||||||||||||||||
Net Weight (kg) | 0,780 Kg | |||||||||||||||||||||||||||||||||
Packaging Dimension | 118,00 x 212,00 x 63,00 | |||||||||||||||||||||||||||||||||
Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
Additional Product Information | ||||||||||||||||||||||||||||||||||
EAN | 4047621009094 | |||||||||||||||||||||||||||||||||
UPC | Not available | |||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
Product Group | 5348 | |||||||||||||||||||||||||||||||||
Group Code | R711 | |||||||||||||||||||||||||||||||||
Country of origin | Germany | |||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | not available | |||||||||||||||||||||||||||||||||
Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
Classifications | ||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Supporting protocol for Data-Highway (EF003058) | - | |
Ambient temperature, upper operating limit (EF009603) | - | °C |
Supporting protocol for other bus systems (EF003062) | - | |
Supporting protocol for ASI (EF003051) | - | |
Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
Degree of protection (NEMA) (EF011959) | - | |
Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
Supporting protocol for PROFIsafe (EF007526) | - | |
Supporting protocol for PROFINET CBA (EF007524) | - | |
Supporting protocol for EtherNet/IP (EF007521) | - | |
Temperature compensated overload protection (EF009604) | - | |
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
Supporting protocol for TCP/IP (EF003050) | - | |
Supporting protocol for DeviceNet (EF003059) | - | |
Supporting protocol for LON (EF003017) | - | |
Number of command positions (EF001372) | - | |
Supporting protocol for PROFINET IO (EF007525) | - | |
Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
Rated control supply voltage Us at DC (EF003980) | - | V |
Supporting protocol for SERCOS (EF006657) | - | |
Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
Supporting protocol for SafetyBUS p (EF007527) | - | |
Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
Supporting protocol for PROFIBUS (EF003052) | - | |
Supporting protocol for CAN (EF003053) | - | |
Supporting protocol for Modbus (EF003057) | - | |
Supporting protocol for SUCONET (EF003060) | - | |
External reset possible (EF003426) | - | |
Supporting protocol for INTERBUS-Safety (EF006662) | - | |
Supporting protocol for DeviceNet Safety (EF007520) | - | |
Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
Suitable for emergency stop (EF001433) | - | |
Rail mounting possible (EF003972) | - | |
Supporting protocol for Foundation Fieldbus (EF007522) | - | |
Supporting protocol for INTERBUS (EF003054) | - | |
Type of motor starter (EF009598) | Other | |
With short-circuit release (EF006691) | true | |
Voltage type for actuating (EF008242) | DC / DC | |
Rated operation power at AC-3, 400 V (EF001364) | 0.55 | kW |
Rated operation current Ie (EF001443) | 1.5 | A |
Rated operation current at AC-3, 400 V (EF009602) | 1.5 | A |
Overload release current setting (EF002336) | ['1.1', '1.6'] | A |
Number of auxiliary contacts as normally open contact (EF001376) | 1 | |
Number of auxiliary contacts as normally closed contact (EF001377) | 1 | |
Release class (EF006668) | CLASS 10 | |
Type of electrical connection of main circuit (EF006819) | Spring clamp connection | |
With transformer (EF000278) | false | |
Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
Number of indicator lights (EF001965) | 0 | |
With fuse (EF006693) | false | |
Degree of protection (IP) (EF005474) | IP20 | |
Width (EF000008) | 45.0 | mm |
Height (EF000040) | 198.0 | mm |
Depth (EF000049) | 97.0 | mm |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RA2115-1AE15-1FB4 3RA2115-1AE15-1FB4 EN_3RA2115-1AE15-1FB4.pdf | 247 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.