VAL-MS-T1/T2 48/12.5/O 2906281 PHOENIX CONTACT Lightning/surge arrester type 1/2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 48/12.5/O 2906281 PHOENIX CONTACT Lightning/surge arrester type 1/2

VAL-MS-T1/T2 48/12.5/O

2906281

PHOENIX_CONTACT

12

Lightning/surge arrester type 1/2

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2906281
Packing unit12 pc
Minimum order quantity12 pc
NoteMade to Order (non-returnable)
Catalog pagePage 39 (C-4-2017)
GTIN4055626063065
Weight per Piece (excluding packing)149.000 g
Custom tariff number85363090
Country of originDE (Germany)

Dimensions

Height77.1 mm
Width17.5 mm
Depth89.2 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitudemax. 2000 m
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationI / II
T1 / T2
I
EN typeT1 / T2
IEC power supply systemDC
Mode of protectionL-PEN
(L+) - (L-)
(L-) - PE
(L+) - PE
Mounting typeDIN rail: 35 mm
Colorblack
Housing materialPBT
Degree of pollution2
Flammability rating according to UL 94V0
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messageOptical, remote indicator contact

Protective circuit

Nominal voltage UN-48 V DC (RRH)
60 V DC
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
100 V DC
Maximum continuous operating voltage UC(L-PEN)75 V AC
100 V DC
75 V AC
100 V DC
Rated load current IL80 A
80 A
Residual current IPE≤ 0.6 mA
≤ 0.6 mA
Standby power consumption PC≤ 45 mVA
≤ 45 mVA
Nominal discharge current In(8/20) µs12.5 kA
Maximum discharge current Imax(8/20) µs30 kA
30 kA
Maximum discharge current Imax(8/20) µs (L-N)30 kA
Maximum discharge current Imax(8/20) µs (L-PEN)30 kA
Impulse discharge current (10/350) µs, charge6.25 As
Impulse discharge current (10/350) µs, specific energy39 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp12.5 kA
12.5 kA
Impulse discharge current (10/350) µs (L-N), charge6.25 As
6.25 As
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
12.5 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.4 kV
Voltage protection level Up(L-N)≤ 0.4 kV
Voltage protection level Up(L-PEN)≤ 0.4 kV
Residual voltage Ures≤ 0.4 kV (at In)
≤ 0.35 kV (at 10 kA)
≤ 0.3 kV (at 5 kA)
≤ 0.275 kV (at 4 kA)
≤ 0.25 kV (at 3 kA)
TOV behavior at UT100 V AC (5 s / withstand mode)
130 V DC (5 s / withstand mode)
Response time tA≤ 25 ns
Response time tA(L-N)≤ 25 ns
Response time tA(L-PEN)≤ 25 ns
Max. backup fuse with V-type through wiring80 A AC (gG - 16 mm²)
80 A AC (gG - 16 mm²)
Max. backup fuse with branch wiring160 A AC (gG)
160 A AC (gG)

Connection data

Connection methodScrew connection
Screw threadM5
Tightening torque4.5 Nm
30 lbf-in. (UL)
Stripping length16 mm
Conductor cross section flexible1.5 mm² ... 25 mm²
Conductor cross section solid1.5 mm² ... 35 mm²
Conductor cross section AWG15 ... 2
10 ... 2 (UL)

UL specifications

SPD Type1CA
Maximum continuous operating voltage MCOV75 V AC
Maximum continuous operating voltage MCOV (L-N)75 V AC
Maximum continuous operating voltage MCOV (L-G)75 V AC
Maximum continuous operating voltage MCOV (L+) - (L-)100 V DC
Maximum continuous operating voltage MCOV (L+/L-) - G100 V DC
Nominal voltage60 V DC
Mode of protectionL-L
L-G
(L+) - (L-)
(L+) - G
(L-) - G
Power distribution systemSingle phase
Voltage protection rating VPR400 V
Voltage protection rating VPR (L-N)400 V
Measured limiting voltage MLV1240 V
Measured limiting voltage MLV (L-G)1240 V
Measured limiting voltage MLV (L+) - (L-)1230 V
Nominal discharge current In20 kA
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(L+) - (L-)20 kA

UL connection data

Conductor cross section AWG10 ... 2
Tightening torque30 lbf-in.

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN.pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.