TRIO-UPS/1AC/24DC/ 5 2866611 PHOENIX CONTACT Uninterruptible power supply with integrated power supply unit,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TRIO-UPS/1AC/24DC/ 5 2866611 PHOENIX CONTACT Uninterruptible power supply with integrated power supply unit,..

TRIO-UPS/1AC/24DC/ 5

2866611

PHOENIX_CONTACT

Available

Ship on today

Uninterruptible power supply with integrated power supply unit, 5A, in combination with MINI-BAT/24/DC/1.3 AH, QUINT-BAT/24DC 3,4AH, 7,2AH or 12 AH

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Power. Power Supply - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$321.98
2+$313.00
3+$309.44
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width60 mm
Height130 mm
Depth118 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Max. permissible relative humidity (operation)95 % (at 25 °C, non-condensing)
Noise immunityEN 61000-6-2:2005

Input data

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC (Derating < 90 V AC: 2.5%V)
100 V DC ... 350 V DC (UL508: 100 ... 250 V)
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Inrush surge current< 44 A (< 1.3 A2s)
Power failure bypasssee diagram
Buffer period20 min. (5 A)
Input fuse6.3 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi)approx. 0.5
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC
Setting range of the output voltage22.5 V DC ... 29.5 V DC (Network operation; in the buffer mode, dependent on the battery voltage of 27.9 V DC ... 19.2 V DC)
Nominal output current5 A (-25°C ... 55°C)
Derating55 °C ... 70 °C (2.5%/K)
Connection in parallelYes, 2
Connection in seriesNo
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Residual ripple< 10 mVPP
Output power120 W
Typical response time150 ms (230 V AC)
Peak switching voltages nominal load< 25 mVPP

General

IQ technologyNo
Net weight1.1 kg
Memory mediumExternal, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah
Efficiency> 88 % (230 V AC, network operation)
> 86 % (120 V AC, network operation)
> 86 % (Battery operation)
Insulation voltage input/output4 kV (type test)
2 kV (Routine test)
Protection classI
MTBF (IEC 61709, SN 29500)> 596000 h (40°C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsCan be aligned: Horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length8 mm
Screw threadM3

Signaling

Output voltage+ 24 V
Status displayGreen LED
Note on status displayMains voltage OK: Green LED, static at
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Screw threadM3
Output nameAlarm
Output descriptionTransistor switching output
Maximum switching voltage≤ 24 V
Output voltage24 V
Continuous load current≤ 200 mA
Status displayAlarm
Note on status displayRed LED, static at
Output nameBattery charge
Output descriptionTransistor switching output
Maximum switching voltage≤ 24 V
Output voltage24 V
Continuous load current≤ 200 mA
Status displayBattery (battery charge) is being charged
Note on status displayYellow LED, flashing
Output nameBattery mode
Output descriptionTransistor switching output
Type of signalingLED, active switching output
Maximum switching voltage≤ 24 V
Output voltage24 V
Continuous load current≤ 200 mA
Status displayBattery operation (Battery Mode)
Note on status displayLED yellow, static at

Charging process

Charge characteristic curveI/U characteristic curve
Battery presence check/time interval60 s
Charge current0.2 A ... 1.5 A (Default 1.0 A)
End-of-charge voltage25 V DC ... 30 V DC (Default 27.6 V DC)
Temperature compensation0 mV/K ... 200 mV/K (42 mV/K by default)
Quality check of battery4 h ... 200 h (Default 12 h)
Deep discharge protection18 V DC ... 21 V DC (Default 19.2 V DC)
Alarm signaling threshold18 V DC ... 30 V DC (Default 20.4 V DC)

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2866611-TRIO-UPS/1AC/24DC/ 5 English 157 Kbytes PHOENIX CONTACT-2866611-TRIO-UPS/1AC/24DC/ 5

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.