Safety relays
Safety relay for emergency stop control and safety doors up to SIL 3 or category 4, PL e according to EN ISO 13849, two-channel operation, 3 trip circuits, nominal input voltage 24 V DC, plug-in screw terminal block
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 2-channel operation, 3 enabling current paths, nominal input voltage: 24 V DC, plug-in screw terminal block
Relays > Device for monitoring of safety-related circuits
Safety
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Note on application | |
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Emergency stop |
| Safety door | |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Data management status | |
| Article revision | 06 |
| Maximum power dissipation for nominal condition | 16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | See section “Insulation coordination” |
| General | |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Power consumption at US | typ. 1.68 W (DC) |
| Rated control supply current IS | typ. 70 mA |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 70 mA DC (at Us) |
| Inrush current | < 3.5 A (Δt = 3 ms at Us) |
| < 100 mA (Δt = 500 ms, with Us/Ixat S12) | |
| > -100 mA (Δt = 300 ms, with Us/Ixat S22) | |
| < 6 mA (with Us/Ixto S34) | |
| < 6 mA (with Us/Ixto S35) | |
| Current consumption | typ. 38 mA (S12) |
| typ. -38 mA (S22) | |
| typ. 0 mA (with Us/Ixto S34) | |
| typ. 1 mA (with Us/Ixto S35) | |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Filter time | 5 ms (at A1 in the event of voltage dips at Us) |
| No test pulses permitted | |
| Typical response time | 100 ms (Monitored/manual start) |
| 150 ms (automatic start) | |
| Typ. starting time with Us | 250 ms (when controlled via A1) |
| Typical release time | 20 ms (on demand via the sensor circuit) |
| 45 ms (on demand via A1) | |
| Concurrence | ∞ |
| Recovery time | 1 s (following demand of the safety function) |
| < 1 s (Boot time) | |
| Protective circuit | Surge protection; Suppressor diode |
| Max. permissible overall conductor resistance | approx. 50 Ω (Input and start circuits at US) |
| Operating voltage display | Green LED |
| Status display | LED (green) |
| Contact switching type | 3 enabling current paths |
| 1 signaling current path | |
| Contact material | AgSnO2, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 10 V AC/DC |
| Limiting continuous current | 6 A (Observe derating and load limit curve) |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(Enabling current paths) |
| 36 A2(Signaling current path 41/42) | |
| Interrupting rating (ohmic load) max. | see load limit curve |
| Switching capacity min. | 100 mW |
| Switching capacity in accordance with IEC 60947-5-1 | 6 A (DC13, enabling current paths) |
| 5 A (AC15, enabling current paths) | |
| 2 A (DC13, signaling current paths) | |
| 1.5 A (AC15, signaling current paths) | |
| Output fuse | 10 A gL/gG (Enabling current paths) |
| 4 A gL/gG (Low-demand enabling current paths) | |
| 6 A gL/gG (Signaling current path) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 4 |
| Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly note | See derating curve |
| Mounting position | vertical or horizontal |
| Feature Name | Feature Value |
|---|---|
| Model (EF000010) | Basic device |
| Suitable for rail mounting (EF003972) | Yes |
| With detachable clamps (EF003340) | Yes |
| Type of electric connection (EF003961) | Screw connection |
| Suitable for monitoring of position switches (EF007270) | Yes |
| Suitable for monitoring of emergency-stop circuits (EF007268) | Yes |
| Suitable for monitoring of valves (EF007272) | No |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | No |
| Suitable for monitoring of tactile sensors (EF007271) | No |
| Suitable for monitoring of magnetic switches (EF007266) | Yes |
| Suitable for monitoring of proximity switches (EF007267) | No |
| Evaluation inputs (EF008245) | Other |
| With start input (EF003342) | No |
| With muting function (EF004057) | No |
| With feedback circuit (EF003343) | Yes |
| Release-delay (EF001129) | 0.15 s |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 |
| Number of outputs, safety related, delayed, with contact (EF003345) | 0 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | 0 |
| Number of outputs, signalling function, delayed, with contact (EF003349) | 0 |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 0 |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 0 |
| Stop category according to IEC 60204 (EF007498) | Other |
| With approval for BG BIA (EF004145) | No |
| With approval according to UL (EF001783) | No |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 99 mm |
| Depth (EF000049) | 114.5 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2900509-PSR-SCP- 24UC/ESAM4/3X1/1X2/B | 143 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.