ELR W3-230AC/500AC- 2I 2297044 PHOENIX CONTACT Hybrid motor starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR W3-230AC/500AC- 2I 2297044 PHOENIX CONTACT Hybrid motor starter

ELR W3-230AC/500AC- 2I

2297044

PHOENIX_CONTACT

Hybrid motor starter

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $238.96
Unit price: $238.96

Quantity Price
1+$238.96
2+$220.61
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2297044
Packing unit1 pc
Catalog pagePage 18 (C-7-2013)
GTIN4046356170574
Weight per Piece (excluding packing)280.100 g
Custom tariff number85371098
Country of originDE (Germany)

Width22.5 mm
Height106.6 mm
Depth113.7 mm
Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Device supply

Rated control circuit supply voltage US230 V AC
Control supply voltage range92 V AC ... 253 V AC
Rated control supply current IS4 mA
Mains frequency40/100 Hz
Type of protectionSurge protection

Input data

Input nameControl input right/left
Rated actuating voltage UC230 V AC
Triggering voltage range92 V AC ... 253 V AC
Rated actuating current IC7 mA
Switching threshold44 V AC (“0” signal)
85 V AC (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Typical response time< 35 ms
Typical turn-off time< 80 ms

Output data load output

Output nameAC output
Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie2.4 A (AC-51)
2.4 A (AC-53a)
Mains frequency50/60 Hz
Load current range180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Residual voltage< 0.3 V
Surge current100 A (t = 10 ms)
Type of protectionSurge protection

Output data reply output

Output nameAcknowledge output
NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT
Switching capacity according to IEC 60947-5-13 A (230 V, AC15)
2 A (24 V, DC13)

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionVertical (horizontal DIN rail)
Mounting typeDIN rail mounting
Assembly instructionsCan be aligned with spacing = 20 mm
Operating mode100% operating factor
Maximum power dissipation4.7 W
Minimum power dissipation2.6 W
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm
Connection nameLoad circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

UL data

SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA2.4 A (500 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX

Insulation characteristics

Rated insulation voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
DesignationInsulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
InsulationSafe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
DesignationIsolation characteristics between the control input and control supply voltage to auxiliary circuit
InsulationSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsDIN EN 50178
EN 60947
IEC 61508
ISO 13849
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]

Approvals/conformities

Safety Integrity Level according to IEC 61508≤ 3 (Safe shutdown)
2 (Motor protection)
Category acc. to EN ISO 13849≤ 3 (Safe shutdown)
Performance level according to ISO 13849≤ e (Safe shutdown)
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
EU-type examination certificatePTB 07 ATEX 3145
UL certificateNLDX.E228652

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.