PSR-MC60-2NO-1DO-24DC-SC 2700571 PHOENIX CONTACT Safety relays View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSR-MC60-2NO-1DO-24DC-SC 2700571 PHOENIX CONTACT Safety relays

PSR-MC60-2NO-1DO-24DC-SC

2700571

PHOENIX_CONTACT

Safety relays

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2700571
Packing unit1 pc
Catalog pagePage 257 (C-6-2017)
GTIN4046356988353
Weight per Piece (excluding packing)147.300 g
Custom tariff number85371098
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width12.5 mm
Height112.2 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-35 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Power supply

Rated control circuit supply voltage US24 V DC -20 % / +25 %
19.2 V DC ... 30 V DC
Rated control supply current IStyp. 35 mA
Power consumption at UStyp. 0.9 W
Inrush currenttyp. 20 A (Δt = 10 µs at Us)
Filter time10 ms (For the logic. At A1 in the event of voltage dips at Us)
Protective circuitSurge protection Suppressor diode
Protection against polarity reversal for rated control circuit supply voltage

Digital inputs

Inrush current< 5.5 mA (with Us/Ixat S12/S35)
> -5.5 mA (with Us/Ixto S22)
Current consumption< 5.1 mA (with Us/Ixat S12/S35)
> -5.1 mA (with Us/Ixto S22)
Voltage at input/start and feedback circuit24 V DC -20 % / +25 %
Max. permissible overall conductor resistance150 Ω
Concurrence input 1/2< 0.5 s

Relay outputs: enabling current path

Output nameEnabling current path
Output descriptionsafety-related N/O contacts
Number of outputs2 (undelayed)
Contact type2 enabling current paths
Contact materialAgSnO2(enabling current path)
Switching voltagemin. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Limiting continuous current6 A (observe derating)
Inrush currentmin. 3 mA
max. 6 A
Sq. Total current72 A2(observe derating)
Switching capacitymin. 60 mW
Switching frequency1 Hz
Mechanical service life10x 106cycles
Output fuse6 A gL/gG (N/O contact)

Alarm outputs

Output descriptionnon-safety-related
Number of outputs1 (digital, PNP)
Voltage22 V DC (Us- 2 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Short-circuit protectionYes

Times

Typical response time at US< 40 ms
Typical release time at US< 10 ms (when controlled via S12/S22)
< 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted)
Restart time< 2 s (Boot time)
Recovery time< 500 ms

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
Nominal operating mode100% operating factor
Net weight147.3 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow
Status display5 x bi-color LED

Connection data

Connection methodScrew connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Safety-related characteristic data

Stop category0
Type classIIIA
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)1 (4 A DC13; 5 A AC15; 8760 switching cycles/year)
DesignationEN ISO 13849
Performance level (PL)c (4 A DC13; 5 A AC15; 8760 switching cycles/year)
Category1 (4 A DC13; 5 A AC15; 8760 switching cycles/year)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)1 (4 A DC13; 5 A AC15; 8760 switching cycles/year)

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage250 V AC
250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 6 kV:
between (A1, A2, S11, S12, S21, S22, S35, M1) and enabling current path (13/14)
between (A1, A2, S11, S12, S21, S22, S35, M1) and enabling current path (23/24)
between enabling current paths
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g
ConformanceCE-compliant

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE AUTOMATION PHOENIX EN.pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.