MACX MCR-EX-T-UIREL-UP-SP 2924799 PHOENIX CONTACT Temperature measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-T-UIREL-UP-SP 2924799 PHOENIX CONTACT Temperature measuring transducer

MACX MCR-EX-T-UIREL-UP-SP

2924799

PHOENIX_CONTACT

Temperature measuring transducer

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $571.79
Unit price: $571.79

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2924799
Packing unit1 pc
Catalog pagePage 150 (C-5-2017)
GTIN4046356629096
Weight per Piece (excluding packing)200.000 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width35 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)typ. 5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Shock15g, according to IEC 60068-2-27
Vibration (operation)5g, accordance to IEC 60068-2-6

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Input signal range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Input signal range-1000 mV ... 1000 mV

Output data

Configurable/programmableYes
Max. voltage output signal± 11 V
Current output signal4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Max. current output signal22 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output≤ 600 Ω (at 20 mA)
Behavior in the event of a sensor erroraccording to NE 43 or freely configurable
Output nameRelay output
Configurable/programmableno
Contact type3 PDTs
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC (250 V DC)
Maximum inrush current2 A (250 V AC)
2 A (28 V DC)
Mechanical service life1x 105cycles

Power supply

Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Typical current consumption< 100 mA (24 V DC)
Power consumption< 2.4 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

Maximum transmission error0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Maximum temperature coefficient0.01 %/K
Step response (0–99%)typ. 1000 ms (With SIL)
typ. 700 ms (Without SIL)
Status displayGreen LED (supply voltage, PWR)
Red LED, flashing (line, sensor error, ERR)
Red LED (module error, ERR)
Yellow LED (switching output)
Flammability rating according to UL 94V0
Degree of pollution2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC directive
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output/power supply
Electrical isolation2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/switching output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationOutput/supply
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
ConformanceCE-compliant
ATEX II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 G Ex nA nC ic IIC T4 Gc X
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC ic IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
SIL2

Safety data

Max. internal inductance Linegligible
Max. internal capacitance Ci44 nF
Max. output voltage Uo6 V
Max. output current Io7.4 mA
Max. output power Po11 mW
GroupIIC
Max. external inductivity Lo100 mH
Max. external capacity Co1.3 µF
GroupIIC
Max. external inductivity Lo10 mH
Max. external capacity Co1.7 µF
GroupIIC
Max. external inductivity Lo1 mH
Max. external capacity Co2.6 µF
GroupIIB
Max. external inductivity Lo100 mH
Max. external capacity Co6.8 µF
GroupIIB
Max. external inductivity Lo10 mH
Max. external capacity Co9.2 µF
GroupIIB
Max. external inductivity Lo1 mH
Max. external capacity Co15 µF
Safety-related maximum voltage Um253 V AC/DC

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value2 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2 %

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Electrical isolation4-way, between input/output/power supply/switching output
Flammability rating according to UL 94V0
Shock15g, according to IEC 60068-2-27
Vibration (operation)5g, accordance to IEC 60068-2-6
ConformanceCE-compliant
ATEX II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 G Ex nA nC ic IIC T4 Gc X
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC ic IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
GroupIIC
IIC
IIC
IIB
IIB
IIB

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.