RIF-0-OPT-24DC/24DC/2 2905293 PHOENIX CONTACT Solid-state relay module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RIF-0-OPT-24DC/24DC/2 2905293 PHOENIX CONTACT Solid-state relay module

RIF-0-OPT-24DC/24DC/2

2905293

PHOENIX_CONTACT

Solid-state relay module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $39.33
Unit price: $39.33

Quantity Price
1+$39.33
2+$39.34
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2905293
Packing unit10 pc
Catalog pagePage 336 (C-5-2017)
GTIN4046356945417
Weight per Piece (excluding packing)23.000 g
Custom tariff number85364110
Country of originHU (Hungary)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height93 mm
Depth66 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Input voltage range19.2 V DC ... 28.8 V DC
Rated actuating voltage UC24 V DC
"0" signal switching threshold in reference to UC< 0.4
"1" signal switching threshold in reference to UC> 0.8
Typical response time20 µs
Typical turn-off time300 µs
Status displayYellow LED
Type of protectionFree-wheeling diode
Transmission frequency300 Hz
Power dissipation for nominal condition0.2 W

Output data

Output voltage range3 V DC ... 33 V DC
Limiting continuous current3 A (see derating curve)
Maximum inrush current15 A (10 ms)
Surge voltage protection> 33 V
Voltage drop at max. limiting continuous current< 200 mV
Output circuit2-wire, floating
Type of protectionReverse polarity protection
Surge protection

Connection data 1

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross section AWG24 ... 16

Connection data 2

Connection nameOutput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross section AWG24 ... 16

General

Test voltage input/output2.5 kVrms(50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V2
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Degree of pollution2
Overvoltage categoryIII

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage260 V AC
Rated surge voltage4 kV
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.