Key Commercial Data

Orderkey2866653
Packing unit1 pc
Catalog pagePage 237 (C-4-2017)
GTIN4046356147989
Weight per Piece (excluding packing)250.000 g
Custom tariff number85044030
Country of originCN (China)

Dimensions

Width35 mm
Height99 mm
Depth95 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)100 % (condensation permitted)
Degree of pollution2

Input data

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
AC frequency range45 Hz ... 65 Hz
Current consumption0.75 A (120 V AC)
0.45 A (230 V AC)
Nominal power consumption88 VA
Inrush surge current< 15 A (typical)
Mains bufferingtyp. 35 ms (120 V AC)
typ. 150 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (AC: Characteristics B, C, D, K)

Output data

Nominal output voltage24 V DC ±1 %
Nominal output current (IN)1.5 A (-25 °C ... 60 °C)
POWER BOOST (IBoost)2 A (-25°C ... 40°C)
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance35 V DC
Residual ripple< 40 mVPP(with nominal values)
Output power36 W
Typical response time< 0.5 s
Peak switching voltages nominal load< 20 mVPP(20 MHz)
Maximum power dissipation in no-load condition1.5 W
Power loss nominal load max.6.5 W

General

Net weight0.25 kg
Efficiency> 84 % (for 230 V AC and nominal values)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Insulation voltage input / PE4 kV AC (type test)
3 kV AC (routine test)
Protection classII (in closed control cabinet)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 2789000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Connection data for signaling

Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM4

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Standards/regulationsEN 60079-0
Connection in acc. with standardCUL
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageEN 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Rail applicationsEN 50121-4
ATEX II 3 G Ex nA nC IIC T4 Gc X

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.