Dimensions

Height45 mm
Width17.7 mm
Depth52 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesDIN VDE 0110-1
IEC 60664-1
Mounting typeOn base element
TypeDIN rail module, two-section, divisible
Number of positions5
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
VDE requirement classC1
C2
C3
D1
Nominal voltage UN32 V DC
Maximum continuous voltage UC36 V DC
Maximum continuous voltage UC (wire-wire)36 V DC
Nominal current IN1.6 A
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 5 µA (with PT 4-BE)
Nominal discharge current In (8/20) µs (Core-Core)100 A
Nominal discharge current In (8/20) µs (Core-Earth)10 kA
Max. discharge current Imax (8/20) µs maximum (Core-Core)100 A
Max. discharge current Imax (8/20) µs maximum (Core-Earth)10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core)23 A
Impulse discharge current (10/350)˽µs, peak value limp1 kA
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 75 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 1.3 kV (with PT 4-BE)
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 75 V
Voltage protection level Up (core-core)≤ 75 V (C3 - 25 A)
Voltage protection level Up (core-ground)≤ 1.3 kV (C1 - 1.5 kV)
≤ 1.3 kV (C2 - 9 kV)
≤ 1.3 kV (D1 - 500 A)
Response time tA (Core-Core)≤ 1 ns
Response time tA (Core-Earth)≤ 100 ns
Resistance in series≤ 1 Ω
Impulse durability (conductor-conductor)C3 - 25 A
Impulse durability (conductor-ground)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
D1 (500 A)

Connection data

Connection methodScrew connection (in connection with the base element)
Connection type INPLUGTRAB plug-in system
Connection type OUTPLUGTRAB plug-in system

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2800755-PT 2X2-FF-ST English 118 Kbytes PHOENIX CONTACT-2800755-PT 2X2-FF-ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.