PLC-OSC- 24DC/230AC/ 2/ACT 2982760 PHOENIX CONTACT PLC-INTERFACE for output functions, consisting of PLC-BSC.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OSC- 24DC/230AC/ 2/ACT 2982760 PHOENIX CONTACT PLC-INTERFACE for output functions, consisting of PLC-BSC..

PLC-OSC- 24DC/230AC/ 2/ACT

2982760

PHOENIX_CONTACT

10

Available

Ship on today

PLC-INTERFACE for output functions, consisting of PLC-BSC…/ACT basic terminal block with screw connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 24 V DC, output: 24 - 253 V AC/2 A

More details


Converters

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$39.28
20+$37.88
30+$37.22
40+$36.84
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C

Input data

Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.8 ... 1.2
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN9 mA
Typical response time10 ms
Typical turn-off time10 ms
Operating voltage displayYellow LED
Type of protectionProtection against polarity reversal
Free-wheeling diode
Protective circuit/componentPolarity protection diode
Damping diode
Transmission frequency10 Hz

Output data

Output nominal voltage230 V AC
Output voltage range24 V AC ... 253 V AC
Limiting continuous current2 A (see derating curve)
Maximum inrush current30 A (10 ms)
Min. load current25 mA
Leakage currenttyp. 1 mA
Surge current30 A (tp = 10 ms)
Max. load value4 A2s (tp = 10 ms, at 25 °C)
Peak offstate voltage600 V
Voltage drop at max. limiting continuous current≤ 1 V
Output circuit2-conductor floating, zero voltage switch
Type of protectionSurge protection

Connection data, input side

Connection nameInput side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionsee to derating
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulationBasic insulation
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2982760-PLC-OSC- 24DC/230AC/ 2/ACT English 116 Kbytes PHOENIX CONTACT-2982760-PLC-OSC- 24DC/230AC/  2/ACT

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.