IBS RL 400 MLR R DIO6/1 LK 2734769 PHOENIX CONTACT Motor starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IBS RL 400 MLR R DIO6/1 LK 2734769 PHOENIX CONTACT Motor starter

IBS RL 400 MLR R DIO6/1 LK

2734769

PHOENIX_CONTACT

Motor starter

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2734769
Packing unit1 pc
Catalog pagePage 237 (C-6-2017)
GTIN4017918906863
Weight per Piece (excluding packing)3,800.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width185.1 mm
Height193 mm
Depth138 mm

Ambient conditions

Ambient temperature (operation)0 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)100 %
Permissible humidity (storage/transport)95 % (non-condensing)
Air pressure (operation)860 hPa ... 1080 hPa (up to 1500 m above sea level)
Air pressure (storage/transport)660 hPa ... 1080 hPa (up to 3500 m above sea level)
Degree of protectionIP65/IP67

Interfaces

DesignationINTERBUS
Connection methodFiber optics
Transmission speed500 kbps

Power supply for module electronics

Supply voltage24 V DC
Supply voltage range18.5 V DC ... 32 V DC (including ripple)
Ripple3.6 Vpp

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointTerminal strip X11 and X12
Number of positions4
Permissible conductor cross section2.5 mm² ... 4 mm²
Operating voltage200 V AC ... 440 V AC (conductor voltage)
Max. current carrying capacity20 A

Motor starter, output

Connection methodPOWER-COMBICON
Number1
Designation connection pointX10
Number of positions8
Pg screw connectionPg16
Operating voltage200 V AC ... 440 V AC
Frequency range50 Hz ... 60 kHz
Nominal current range0.2 A ... 8 A (parameterizable, observe derating)
Utilization categoryOn the basis of AC 3
Switching rate5 cycles per minute, maximum
Motor startup time1 s

Motor monitoring

ParameterizationVia INTERBUS
Overspeed tripping≥ 40 A (after 1 second at Inom> 3.6 A)

Motor starter, brake

Continuous load currentmax. 1 A
Type of contactMechanical relay contact
Connection technologyPOWER-COMBICON terminal strips
Connection voltage12 V AC/DC ... 440 V AC/DC

Digital inputs

Input nameDigital inputs
Number of inputs6
Connection methodM12 connector
Connection technology3, 4-wire
Number of positions5
Input voltage24 V DC (DIN EN 61131-2)
Input voltage range "0" signal0 V ... 5 V
Input voltage range "1" signal11 V ... 30 V
Typical input current per channel5 mA (for US1= 24 V)
Filter time3 ms
Power supply for sensorsUINI= US1minus 1 V 50 mA Protected against inductive reverse voltages, electronically protected against short-circuiting

Digital outputs

Number of outputs1
Connection methodM12 connector
Number of positions5
Output current0.5 A
Minimum output voltage with nominal currentUS1minus 2 V
Type of protectionElectronic short-circuit/overload protection

General

Mounting typeWall mounting
Net weight3800 g
Diagnostics messagesMains failure, phase failure, blown fuse Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Sensor supply failure Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Failure of the actuator supply Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor overcurrent Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Output stage cannot be controlled Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Module error during self test Message to the master
Mounting typeon mounting plate

Standards and Regulations

Air clearances and creepage distancesaccording to EN 50178: 1998
Protection classI, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.