Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.

Temperature converter, transforms signals from heat resistors and resistors into analog signals of 0/4-20 mA. Free programmable, screw connection, safety integrity level, 3-way galvanic separation, standard configuration.

More details


Sensors > Temperature transformer

INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $477.55
Unit price: $477.55
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey1050192
Packing unit1 pc
Catalog pagePage 130 (C-5-2019)
GTIN4055626666105
Weight per Piece (excluding packing)0.000 g
Custom tariff number85437090
Country of originDE (Germany)

Drawings



Block diagram

Block diagram

Pictogram

Pictogram



Back to top

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Width12.5 mm
Height112.5 mm
Depth114.5 mm
Back to top

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Back to top

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Temperature measuring range-200 °C ... 850 °C (Range depending on the sensor type)
Input signal range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Cable resistance≤ 50 Ω per cable
Sensor input current10 µA ... 210 µA (up to 2 x 210 µA for 3-conductor)
Measuring range span≥ 50 K
Back to top

Output data

Signal outputCurrent output
Configurable/programmableYes
Current output signal0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Max. current output signal≥ 21 mA
Load/output load current output≤ 600 Ω
Output ripple (current)< 15 µAPP
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined
Back to top

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Power dissipation≤ 0.76 W
Power consumption≤ 1 W
Back to top

General

No. of channels1
Transmission error, typical0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Temperature coefficient, typical0.01 %/K
Step response (0–99%)typ. 1 s
≤ 1.7 s
Alignment zero± 5 %
Alignment span± 5 %
Status displayGreen LED (supply voltage, PWR)
Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR)
Red LED, flashing 1.2 Hz (service operation, ERR)
Red LED, permanently on (module error, ERR)
Electromagnetic compatibilityConformance with EMC directive
Interference emissionEN 61000-6-4
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output/power supply
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex ec ic IIC T4 Gc
IECExEx ec ic IIC T4 Gc
SIL2
Back to top

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value1 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value1 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value1 %
Back to top

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex ec ic IIC T4 Gc
IECExEx ec ic IIC T4 Gc
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCB
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.027210120
eCl@ss 4.127210120
eCl@ss 5.027210120
eCl@ss 5.127210120
eCl@ss 6.027210120
eCl@ss 7.027210120
eCl@ss 8.027200206
eCl@ss 9.027210129
Back to top

ETIM

ETIM 2.0EC001446
ETIM 3.0EC001446
ETIM 4.0EC001446
ETIM 5.0EC001446
ETIM 6.0EC002919
ETIM 7.0EC002919
Back to top

UNSPSC

UNSPSC 6.0130211506
UNSPSC 7.090139121008
UNSPSC 1139121008
UNSPSC 12.0139121008
UNSPSC 13.241112105
UNSPSC 18.041112105
UNSPSC 19.041112105
UNSPSC 20.041112105
UNSPSC 21.041112105
Back to top

ETIM for 1050192 Sensors (EC002919)
Feature Name Feature Value
Measuring range (EF001836) -200 °C
Analogue output 0 mA ... 20 mA (EF006808) No
Analogue output 4 mA ... 20 mA (EF006810) Yes
Analogue output 0 V ... 2 V (EF009886) No
Analogue output 0 V ... 5 V (EF009887) No
Analogue output 0 V ... 10 V (EF006807) No
Analogue output 2 V ... 10 V (EF009888) No
With switching output (EF005225) No
EMC-version (EF001062) Yes
Ambient temperature (EF002386) 70 °C
Weight (EF000167) 0.15 kg

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.