FLT 100 N/PE-1.5 2800303 PHOENIX CONTACT Combination type 1/2 protective device View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FLT 100 N/PE-1.5 2800303 PHOENIX CONTACT Combination type 1/2 protective device

FLT 100 N/PE-1.5

2800303

PHOENIX_CONTACT

Combination type 1/2 protective device

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $322.58
Unit price: $322.58

Quantity Price
1+$322.58
2+$314.12
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2800303
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 31 (C-6-2013)
GTIN4046356535236
Weight per Piece (excluding packing)378.700 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height90 mm
Width35.6 mm
Depth71.2 mm
Horizontal pitch2 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (5 - 500 Hz/2.5 h/X, Y, Z)

General

IEC test classificationI
T1
EN typeT1
IEC power supply systemTN-S
TT
Mode of protectionN-PE
Mounting typeDIN rail: 35 mm
Colorjet black RAL 9005
Housing materialPBT
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messagenone

Protective circuit

Nominal voltage UN240 V AC (TN - only N-PE)
240 V AC (TT - only N-PE)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC260 V AC
Rated load current IL125 A (< 55 °C)
Residual current IPE≤ 0.01 mA
Impulse discharge current (10/350) µs, charge50 As
Impulse discharge current (10/350) µs, specific energy2500 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp100 kA
Follow current interrupt rating Ifi100 A (260 V AC)
Voltage protection level Up≤ 1.5 kV
Residual voltage Ures≤ 1.5 kV (at In)
≤ 1 kV (at 10 kA)
≤ 0.9 kV (at 5 kA)
≤ 0.8 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.5 kV
TOV behavior at UT1200 V AC (200 ms / withstand mode)
Response time tA≤ 100 ns

Connection data

Connection methodScrew terminal blocks
Screw threadM5
Tightening torque4.5 Nm
Stripping length18 mm
Conductor cross section flexible2.5 mm² ... 25 mm²
Conductor cross section solid2.5 mm² ... 35 mm²
Conductor cross section AWG13 ... 2

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (N-G)264 V AC
Mode of protectionN-G
Power distribution systemSplit phase
Nominal frequency50/60 Hz
Measured limiting voltage MLV (N-G)1080 V
Nominal discharge current In(N-G)20 kA

UL connection data

Conductor cross section AWG12 ... 2
Tightening torque40 lbf-in.

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.