PLC-OPT- 5DC/ 24DC/100KHZ 2902969 PHOENIX CONTACT Solid-state relay module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OPT- 5DC/ 24DC/100KHZ 2902969 PHOENIX CONTACT Solid-state relay module

PLC-OPT- 5DC/ 24DC/100KHZ

2902969

PHOENIX_CONTACT

Solid-state relay module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2902969
Packing unit1 pc
Catalog pagePage 410 (C-5-2017)
GTIN4046356702010
Weight per Piece (excluding packing)32.860 g
Custom tariff number85364190
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Degree of protectionIP20

Input data

Nominal input voltage UN5 V DC
Input voltage range in reference to UN0.8 ... 1.2
Input voltage range4 V DC ... 6 V DC
Switching threshold "0" signal in reference to UN< 0.4
Switching threshold "1" signal in reference to UN> 0.8
Typical input current at UN7 mA
Typical response time1.5 µs
Typical turn-off time2 µs
Operating voltage displayYellow LED
Type of protectionReverse polarity protection
Surge protection
Surge voltage protection> 14 V
Transmission frequency100 kHz
Power dissipation for nominal condition0.04 W

Output data

DesignationOutput data
Output voltage range4 V DC ... 30 V DC
Limiting continuous current50 mA
Quiescent current4.3 mA
Surge voltage protection> 35 V
Voltage drop at max. limiting continuous current< 0.5 V
Output circuit3-conductor, ground-referenced
Type of protectionReverse polarity protection
Surge protection

Connection data 1

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

Connection data 2

Connection nameOutput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kVrms(50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Degree of pollution2
Overvoltage categoryII

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage50 V DC
Rated surge voltage0.5 kV
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryII

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.