Product successfully added to your shopping cart
HC-K 6/12-EBUS
1636363
PHOENIX_CONTACT
1
Contact insert
Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Female, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| General | For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench |
| General | Connectors may be operated only when there is no load/voltage. |
| General | The axial screw connection must be established using a 2 mm Allen key (for stranded conductors only) |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Note regarding axial connection technology: Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used. Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use. The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use. Assembly instructions Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Product type | Contact insert with a fixed no. of positions |
| Series | HC-K |
| Application | Power/signal |
| Type | B16 |
| B32 | |
| Number of positions | 18 |
| Connection profile | 6+12+PE |
| Contact numbering | 1 - 6 (power contacts) |
| 11 - 22 (control contacts) | |
| No. of power contacts | 6 |
| No. of control contacts | 12 |
| Contact material type | turned |
| Screwdriver blade | 0.5 x 3.5 mm (control contacts) |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Dimensional drawing | ![]() |
| Width | 34 mm |
| Height | 47 mm |
| Length | 84.1 mm |
| Drill hole distance, horizontal | 77.5 mm |
| Mechanical characteristics | |
| Contact diameter | 4 mm |
| Connection technology | |
| Connection technology | Axial screw connection (power contacts) |
| Screw connection (control contacts) | |
| Conductor connection | |
| Conductor cross section | 2.5 mm² ... 10 mm² (power contacts) |
| 0.2 mm² ... 2.5 mm² (control contact) | |
| Connection cross section AWG | 12 ... 8 (power contacts) |
| 24 ... 14 (control contacts) | |
| Tightening torque | 2 Nm ... 2.5 Nm (PE connection) |
| 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) | |
| 0.5 Nm ... 0.8 Nm (control contacts) | |
| 1.5 Nm (Power 2.5 mm² ... 4 mm²) | |
| 2 Nm (Power 6 mm² ... 10 mm²) | |
| Stripping length of the individual wire | 8 mm +1 mm (Power 6 mm² ... 10 mm²) |
| 10 mm (Signal) | |
| 5 mm +1 mm (Power 2.5 mm² ... 4 mm²) | |
| Rated voltage (III/3) | 690 V |
| 230 V (Conductor-PE) | |
| 400 V (Signal contacts, conductor-conductor) | |
| Rated voltage for power contacts | 230/400 V |
| Rated surge voltage | 8 kV (power contacts) |
| 4 kV (control contacts) | |
| Rated current | 40 A (power contacts) |
| 10 A (control contacts) |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Flammability rating according to UL 94 | V0 |
| Contact material | Cu alloy |
| Contact carrier material | PC |
| Material of contact surface, power contact | Ag |
| Material of contact surface, control contact | Ag |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX CONNECTORS EN .pdf | 58 Mbytes |
|
| PHOENIX CONTACT-1636363-HC-K 6/12-EBUS | 138 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.