PSI-GPRS/GSM-MODEM/RS232-QB 2313106 PHOENIX CONTACT Modem View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSI-GPRS/GSM-MODEM/RS232-QB 2313106 PHOENIX CONTACT Modem

PSI-GPRS/GSM-MODEM/RS232-QB

2313106

PHOENIX_CONTACT

Modem

Industrial GPRS/GSM modem for EN rail mounting. GSM and GPRS. 850 + 900 + 1800 + 1900 MHz. Serial RS-232 interface. TCP/IP stack. Alarm input and output. supply voltage 24 V DC

More details


Safety

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2313106
Packing unit1 pc
Catalog pagePage 366 (C-6-2017)
GTIN4046356166034
Weight per Piece (excluding packing)182.600 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width22.5 mm
Height99 mm
Depth118.6 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Altitude5000 m (For restrictions see manufacturer's declaration)
2000 m (With UL approval)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Electrical isolationVCC // RS-232 // GSM
Test voltage data interfaces1500 V
Test voltage data interface/power supply1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with RED Directive 2014/53/EU
Noise emissionEN 55032
Net weight182.6 g
Housing materialPA V0
Colorgreen
Degree of pollution2
ConformanceCE-compliant
UL, USA/CanadacULus listed UL 508
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X

Power supply

Nominal supply voltage24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
Supply voltage range10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption< 350 mA (24 V DC)
< 80 mA (stand by)

Serial interface

Interface 1V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Connection methodD-SUB 9 plug
File format/codingSerial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length
Transmission length15 m
Data flow control/protocolsSoftware handshake, Xon/Xoff or hardware handshake RTS/CTS

Wireless interface

Interface descriptionGSM / GPRS
Frequency850 MHz (2 W (EGSM))
900 MHz (2 W (EGSM))
1800 MHz (1 W (EGSM))
1900 MHz (1 W (EGSM))
Data rate≤ 85.6 kbps
Antenna50 Ω impedance SMA antenna socket
SIM interface 11.8 volt, 3 volt
GPRSClass 10, Class B
CS1 ... CS4
GSMCSD 9.6/14.4 kbps
Network function4 time slots for receiving data, 2 time slot for transmitting data. The PIN is saved in the modem. After a voltage interruption, there is automatic redialing into the network Integrated TCP/IP Stack, independent connection establishment.
Network checkLED to show data signal quality

Digital outputs

Output nameDigital output
Number of outputs1
Voltage output signal10 V DC ... 30 V DC
Current output signal≤ 80 mA (24 V)
Connection methodDIN rail bus connectors

Digital inputs

Description of the inputDigital input
Number of inputs2
Voltage input signal9 V DC ... 60 V DC
Current input signal5 mA

Standards and Regulations

Electromagnetic compatibilityConformance with RED Directive 2014/53/EU
Type of testFree fall in acc. with IEC 60068-2-32
Test result1 m
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g in each space direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test resultOperation: 15g, 11 ms period, half-sine shock pulse
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test resultStorage: 30g, 11 ms period, half-sine shock pulse
Noise emissionEN 55032
Noise immunityEN 61000-6-2:2005
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Indirect discharge± 6 kV
Standards/regulationsEN 61000-4-3
Frequency rangeTest Level 3
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV
Standards/regulationsEN 55032
EN 61000-4-6
ConformanceCE-compliant
UL, USA/CanadacULus listed UL 508
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.