Product successfully added to your shopping cart
PSI-MOS-RS422/FO 660 T
2708384
PHOENIX_CONTACT
1
FO converters
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2708384 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 331 (C-6-2017) |
GTIN | 4017918974084 |
Weight per Piece (excluding packing) | 197.980 g |
Custom tariff number | 85176200 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -20 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2:2005 |
Transmission channels | 2 (1/1) RD, TD, full duplex |
---|---|
Bit distortion, input | ± 35 % (permitted) |
Bit distortion, output | < 6.25 % |
Electrical isolation | VCC // RS-422 |
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Net weight | 197.98 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 284 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
52 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
MTTF | 861 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
338 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
137 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) | |
II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) | |
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
Class I, zone 2, Ex nC nL IIC T5 X | |
Class I, Div. 2, Groups A, B, C, D |
Nominal supply voltage | 24 V DC (With UL approval) |
---|---|
Supply voltage range | 18 V DC ... 30 V DC |
Max. current consumption | 130 mA |
Typical current consumption | 100 mA (24 V DC) |
Connection method | COMBICON plug-in screw terminal block |
Interface 1 | RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 |
---|---|
Operating mode | full duplex |
Connection method | Pluggable screw connection |
Transmission medium | Copper |
Transmission length | ≤ 1000 m (depending on the data rate, with shielded, twisted data cable) |
Termination resistor | 220 Ω |
100 Ω | |
220 Ω | |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Serial transmission speed | ≤ 2 Mbps |
Transmit capacity, minimum | -4.6 dBm (980/1000 µm) |
---|---|
-16.6 dBm (200/230 µm) | |
Minimum receiver sensitivity | -31.2 dBm |
Wavelength | 660 nm |
Transmission length incl. 3 dB system reserve | 100 m (With F-P 980/1000 230 dB/km with quick mounting connector) |
800 m (With F-K 200/230 10 dB/km with quick mounting connector) | |
Transmission medium | Polymer fiber |
PCF fiber | |
Transmission protocol | Transparent to protocol for RS-422 interface |
Connection method | F-SMA |
Output name | Relay output |
---|---|
Output description | Alarm output |
Number of outputs | 1 |
Maximum switching voltage | 60 V DC |
42 V AC | |
Limiting continuous current | 0.46 A |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 15g, 11 ms period, half-sine shock pulse |
Noise emission | EN 55011 |
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Standards/regulations | EN 61000-4-3 |
EN 61000-4-4 | |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV |
Standards/regulations | EN 55011 |
EN 61000-4-6 | |
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA nC IIC T4 Gc X |
II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) | |
II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) | |
UL, USA/Canada | Class I, Zone 2, AEx nc IIC T5 |
Class I, zone 2, Ex nC nL IIC T5 X | |
Class I, Div. 2, Groups A, B, C, D | |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2708384-PSI-MOS-RS422/FO 660 T | 292 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.