PSI-MOS-RS422/FO 660 T 2708384 PHOENIX CONTACT FO converters View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSI-MOS-RS422/FO 660 T 2708384 PHOENIX CONTACT FO converters

PSI-MOS-RS422/FO 660 T

2708384

PHOENIX_CONTACT

FO converters

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $1,012.95
Unit price: $1,012.95

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2708384
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 331 (C-6-2017)
GTIN4017918974084
Weight per Piece (excluding packing)197.980 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width35 mm
Height99 mm
Depth103 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)30 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Transmission channels2 (1/1) RD, TD, full duplex
Bit distortion, input± 35 % (permitted)
Bit distortion, output< 6.25 %
Electrical isolationVCC // RS-422
Test voltage data interface/power supply1.5 kVrms(50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011
Net weight197.98 g
Housing materialPA 6.6-FR
Colorgreen
MTBF284 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
52 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF861 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
338 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
137 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
 II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)
 II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!)
UL, USA/CanadaClass I, Zone 2, AEx nc IIC T5
Class I, zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D

Power supply

Nominal supply voltage24 V DC (With UL approval)
Supply voltage range18 V DC ... 30 V DC
Max. current consumption130 mA
Typical current consumption100 mA (24 V DC)
Connection methodCOMBICON plug-in screw terminal block

Serial interface

Interface 1RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Operating modefull duplex
Connection methodPluggable screw connection
Transmission mediumCopper
Transmission length≤ 1000 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor220 Ω
100 Ω
220 Ω
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Serial transmission speed≤ 2 Mbps

Optical interface FO

Transmit capacity, minimum-4.6 dBm (980/1000 µm)
-16.6 dBm (200/230 µm)
Minimum receiver sensitivity-31.2 dBm
Wavelength660 nm
Transmission length incl. 3 dB system reserve100 m (With F-P 980/1000 230 dB/km with quick mounting connector)
800 m (With F-K 200/230 10 dB/km with quick mounting connector)
Transmission mediumPolymer fiber
PCF fiber
Transmission protocolTransparent to protocol for RS-422 interface
Connection methodF-SMA

Digital outputs

Output nameRelay output
Output descriptionAlarm output
Number of outputs1
Maximum switching voltage60 V DC
42 V AC
Limiting continuous current0.46 A

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result15g, 11 ms period, half-sine shock pulse
Noise emissionEN 55011
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Standards/regulationsEN 61000-4-3
EN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV
Standards/regulationsEN 55011
EN 61000-4-6
Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
 II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U)
 II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U)
UL, USA/CanadaClass I, Zone 2, AEx nc IIC T5
Class I, zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.