D-UFB-PB 2880642 PHOENIX CONTACT Fine surge protection in a 9-pos. D-SUB plug for PROFIBUS-DP applications w.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

D-UFB-PB 2880642 PHOENIX CONTACT Fine surge protection in a 9-pos. D-SUB plug for PROFIBUS-DP applications w..

D-UFB-PB

2880642

PHOENIX_CONTACT

Available

Ship on today

Fine surge protection in a 9-pos. D-SUB plug for PROFIBUS-DP applications with a transmission speed of up to 12 Mbps.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for information technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+88,67 €
3+84,68 €
5+83,23 €
7+82,39 €
9+81,93 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height58 mm
Width44.5 mm
Depth16.6 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 75 °C
Ambient temperature (storage/transport)-20 °C ... 75 °C
Degree of protectionIP40

General

Housing materialABS, metal-plated
Colorsilver
Standards for cearances and creepage distancesIEC 60664-1
DIN VDE 0110-1
Overvoltage categoryII
Pollution degree2
Mounting typeDirect assembly on the device interface
TypeConnecting plug
Number of positions4
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationC1
C3
B2
VDE requirement classC1
C3
B2
Maximum continuous voltage UC5.2 V DC
Maximum continuous voltage UC (wire-wire)5.2 V DC
Maximum continuous voltage UC (wire-ground)5.2 V DC
Nominal current IN250 mA (25 °C)
Operating effective current IC at UC≤ 100 µA
Residual current IPE≤ 100 µA
Nominal discharge current In (8/20) µs (Core-Core)350 A
Nominal discharge current In (8/20) µs (Core-Earth)350 A
Total surge current (8/20) µs350 A
Max. discharge current Imax (8/20) µs maximum (Core-Core)350 A
Max. discharge current Imax (8/20) µs maximum (Core-Earth)350 A
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 20 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 20 V
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 14 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 14 V
Output voltage limitation (10/700) µs (core-core)≤ 15 V (Uo=4 kV)
Output voltage limitation (10/700) µs (Core-Earth)≤ 15 V (Uo=4 kV)
Residual voltage at In (conductor-conductor)≤ 25 V
Residual voltage at In (conductor-ground)≤ 25 V
Voltage protection level Up (core-core)≤ 25 V (C1 (500 V/250 A))
≤ 15 V (C3 - 25 A)
≤ 15 V (B2 (4 kV/100 A))
Voltage protection level Up (core-ground)≤ 25 V (C1 (500 V/250 A))
≤ 15 V (C3 - 25 A)
≤ 15 V (B2 (4 kV/100 A))
Response time tA (Core-Core)≤ 500 ns
Response time tA (Core-Earth)≤ 500 ns
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 70 MHz
Inductivity in series0.11 µH
Impulse durability (conductor-conductor)C1 - 500 V / 250 A
C3 - 2 kV/25 A
Impulse durability (conductor-ground)C1 (500 A/250 A)
C3 - 2 kV/25 A

Connection data

Connection methodScrew connection & D-SUB-9
Connection type INScrew terminal blocks
Connection type OUTD-SUB-9 connector
Connection method2-wire (shielded)
Screw threadM2
Tightening torque0.25 Nm
Stripping length5 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.16

Connection, equipotential bonding

Connection methodPVC Litz wire, 1.0 mm², 0.5 m length

Standards and Regulations

Standards/regulationsIEC 61643-21
DIN EN 61643-21