MACX MCR-EX-SL-RPSSI-I 2865340 PHOENIX CONTACT Ex i repeater power supply and input signal conditioner, HART.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-SL-RPSSI-I 2865340 PHOENIX CONTACT Ex i repeater power supply and input signal conditioner, HART..

MACX MCR-EX-SL-RPSSI-I

2865340

PHOENIX_CONTACT

Available

Ship on today

Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw connection

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

MSR Components for Ex areas - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$225.63
2+$218.60
3+$215.24
4+$213.20
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width12.5 mm
Height112.5 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Signal inputActive current input, intrinsically safe
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 16 V (20 mA)
> 15.3 V (22.5 mA)
Polarization and surge protectionYes
Signal inputPassive current input, intrinsically safe
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop< 3.5 V

Output data

Signal outputCurrent output (active and passive)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputCurrent output (active and passive)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption< 76 mA (24 V DC / 20 mA / 1000 )
Power consumption< 1.1 W (24 V DC / 20 mA / 1000 )
< 1.8 W (20 mA / 1000 )

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Temperature coefficient, typical< 0.004 %/K
Step response (10-90%)< 200 µs (for jump 4 mA ... 20 mA, load 600)
< 600 µs (for jump 0 mA ... 20 mA, load 600)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II (1) G [Ex ia Ga] IIC/IIB
Ex II (1) D [Ex ia Da] IIIC
Ex II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
Ex I (M1) [Ex ia Ma] I
IECEx[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC/IIB T4 Gc
[Ex ia Ma] I
UL, USA / CanadaUL 61010 Listed
Class I Div 2; IS for Class I, II, III Div 1
Functional Safety (SIL)SIL 2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Safety characteristic data

Integrity requirementIEC 61508 - Low demand
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)90.7 %
λSU4.867 x 10-7 (486.7 FIT)
λSD0
λDU5 x 10-8 (50 FIT)
λDD0
Probability of a hazardous failure on demand (PFDAVG)2.19 x 10-4 (1 year)
8.76 x 10-4 ( years)
1.1 x 10-3 (5 years)
Diagnostic coverage (DC)DCS = 0%, DCD = 0%
Integrity requirementIEC 61508 - High demand
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)90.7 %
λSU4.867 x 10-7 (486.7 FIT)
λSD0
λDU5 x 10-8 (50 FIT)
λDD0
Probability of a hazardous failure per hour (PFHD)4,99 x 10-8
Diagnostic coverage (DC)DCS = 0%, DCD = 0%

Safety data

OperationRepeater power supply operation
Max. output voltage Uo25.2 V
Max. output current Io93 mA
Max. output power Po587 mW
GroupIIC
Max. external inductivity Lo2 mH
Max. external capacity Co107 nF
GroupIIB
Max. external inductivity Lo4 mH
Max. external capacity Co820 nF
Safety-related maximum voltage Um253 V AC (125 V DC)
OperationSignal conditioner operation
Input voltage Ui≤ 30 V
Input current Ii≤ 150 mA
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value1 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value1 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value1 %

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2865340-MACX MCR-EX-SL-RPSSI-I English 157 Kbytes PHOENIX CONTACT-2865340-MACX MCR-EX-SL-RPSSI-I

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.