IL DN BK DI8 DO4-PAC 2897211 PHOENIX CONTACT Bus coupler View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IL DN BK DI8 DO4-PAC 2897211 PHOENIX CONTACT Bus coupler

IL DN BK DI8 DO4-PAC

2897211

PHOENIX_CONTACT

Bus coupler

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2897211
Packing unit1 pc
Catalog pagePage 129 (C-6-2017)
GTIN4046356103015
Weight per Piece (excluding packing)320.000 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight320 g
Note on weight specificationswith connectors
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Interfaces

DesignationDeviceNet™
No. of channels1
Connection methodTWIN COMBICON
Transmission speed500 kbps, 250 kbps, 125 kbps (Can be set via DIP switch or programmed)
Number of positions10
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps (automatic detection, no combined system)

System limits of the bus coupler

Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 61 (on board I/Os are two devices)
Number of devices with parameter channelmax. 8
Number of supported branch terminals with remote bus branch0

Inline potentials

DesignationBus coupler supply UBC; Communications power UL(7.5 V) and the analog supply UANA(24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 0.9 A
DesignationCommunications power (UL)
Supply voltage7.5 V DC ±5 %
Power supply unitmax. 0.8 A DC
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 0.5 A DC
DesignationMain circuit supply (UM)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 8 A DC (sum of UM+ US)
Current consumptionmax. 8 A DC
DesignationSegment circuit supply (US)
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 8 A DC (sum of UM+ US)
Current consumptionmax. 8 A DC

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Connection methodInline connector
Connection technology3-wire
Number of inputs8
Typical response timeapprox. 500 µs
Type of protectionReverse polarity protection
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 11.2 ms
Delay at signal change from 1 to 01.2 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
Connection technology3-wire
Number of outputs4
Type of protectionShort-circuit and overload protection
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H, 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse
Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.