Product successfully added to your shopping cart
PSR-PC50-1NO-1DO-24DC-SC
2904664
PHOENIX_CONTACT
1
Coupling relay
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2904664 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 285 (C-6-2017) |
GTIN | 4046356919937 |
Weight per Piece (excluding packing) | 221.100 g |
Custom tariff number | 85364900 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -20 °C ... 55 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 65 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % (A1/A2) |
---|---|
20.4 V DC ... 26.4 V DC | |
Rated control supply current IS | typ. 65 mA (A1/A2) |
Inrush current | ≤ 200 mA (A1/A2) |
Filter time | < 2 ms (Test pulse duration) |
≥ 100 ms (Test pulse rate) | |
Diagnostic supply voltage UD | 24 V DC -15 % / +10 % (24V/A2) |
Input current at UD | typ. 15 mA (24V/A2; depending on load M1 +100 mA) |
Inrush current at UD | 2.5 A (24V/A2; for 10 µs) |
Protective circuit | Overload protection Suppressor diode |
Number of inputs | 3 (Test point for proof test) |
---|---|
Inrush current | 200 mA (Inputs TP1, TP2 and TP3) |
Current consumption | typ. 20 mA (Input TP1) |
typ. 18 mA (Input TP2) | |
typ. 35 mA (Input TP3) |
Output name | Enabling current path |
---|---|
Output description | safety-related N/O contacts |
Number of outputs | 1 (undelayed) |
Contact type | 1 enabling current path |
Contact material | AgNi, gold-flashed |
Switching voltage | min. 15 V AC/DC without diagnostics |
min. 20 V AC/DC (with diagnostics) | |
max. 250 V AC | |
max. 125 V DC | |
Limiting continuous current | 5 A |
Inrush current | min. 100 mA |
max. 5 A | |
Switching capacity | min. 1.5 W |
Switching frequency | max. 0.5 Hz |
Diagnostic threshold | 20 Ω ... 18 kΩ (lower/upper) |
Max. permissible overall conductor resistance | < 10 Ω (LO/LO' and NI/NI' and load resistance in the event of a short circuit) |
Mechanical service life | approx. 5x 107cycles |
Output description | non-safety-related |
---|---|
Number of outputs | 1 (digital) |
Voltage | 23 V DC |
Current | max. 100 mA |
Short-circuit protection | no |
Output fuse | 150 mA fast blow |
Typical pickup time at US | 30 ms (when controlled via A1) |
---|---|
Typical release time at US | 30 ms (when controlled via A1) |
Recovery time | 1 s |
Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 221.1 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Operating voltage display | Yellow LED |
Status display | Green LED |
Indication | Red LED |
Connection method | Screw connection |
---|---|
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Designation | IEC 61508 - Low demand |
---|---|
Safety Integrity Level (SIL) | 3 (15 % of total SIL) |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | 6 kV/safe isolation (through protective impedance) |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 2g |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA nC IIC T4 Gc |
IECEx | Ex nA nC IIC T4 Gc |
UL, USA/Canada | cULus |
Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X | |
Class I, Div. 2, Groups A, B, C, D, T4 | |
GL | C, EMC2 |
Environmental simulation test | ISA-S71.04 (G3) |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2904664-PSR-PC50-1NO-1DO-24DC-SC | 127 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.