PSR-PS40-1NO-1DO-24DC-SC 2700398 PHOENIX CONTACT Coupling relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSR-PS40-1NO-1DO-24DC-SC 2700398 PHOENIX CONTACT Coupling relay

PSR-PS40-1NO-1DO-24DC-SC

2700398

PHOENIX_CONTACT

Coupling relay

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $220.28
Unit price: $220.28

Quantity Price
1+$220.28
2+$187.58
3+$174.27
4+$172.02
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2700398
Packing unit1 pc
Catalog pagePage 283 (C-6-2017)
GTIN4046356912884
Weight per Piece (excluding packing)123.900 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.8 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Power supply

Rated control circuit supply voltage US24 V DC -15 % / +10 % (A1/A2)
20.4 V DC ... 26.4 V DC
Rated control supply current IStyp. 50 mA (depending on load M1 +100 mA)
Power consumption at UStyp. 1.2 W
Inrush currenttyp. 400 mA (Δt s)
Filter timemax. 2 ms (at A1-A2; test pulse width)
≥ 100 ms (at A1-A2; test pulse rate)
Protective circuitSerial protection against polarity reversal 33 V suppressor diode

Digital inputs

Input nameStart circuit
Number of inputs2 (Non-safety-related start inputs: Y1/Y2)
Inrush current< 10 mA
Current consumption< 5 mA
Voltage at input/start and feedback circuit24 V DC -15 % / +10 %
Max. permissible overall conductor resistance150 Ω

Relay outputs: enabling current path

Output nameEnabling current path
Output description2 N/O contacts in series, without delay, floating
Number of outputs1 (safety-related N/O contacts: 13/14)
Contact type1 enabling current path
Contact materialAgSnO2
Switching voltagemin. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Limiting continuous current6 A (High demand)
4 A (Low demand)
Inrush currentmin. 3 mA
max. 6 A
Sq. Total current36 A2(observe derating)
Switching capacitymin. 60 mW
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Switching capacity according to IEC 60947-5-14 A (24 V (DC13))
5 A (250 V (AC15))
Output fuse6 A gL/gG
4 A gL/gG (for low-demand applications)

Alarm outputs

Output descriptionPNP
Number of outputs1 (non-safety-related)
Voltageapprox. 22 V DC (Us- 2 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Short-circuit protectionno
Output fuse150 mA fast blow

Times

Typical pickup time at US< 200 ms (when controlled via A1, automatic start)
Typical release time at US< 35 ms (when controlled via A1)
Recovery time500 ms

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
Nominal operating mode100% operating factor
Net weight123.9 g
Mounting positionvertical, horizontal, with front of module upward
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow
Operating voltage display1 x yellow LED
Status display2 x green LEDs
Indication1 x red LED

Connection data

Connection methodScrew connection
pluggableno
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.12
Stripping length12 mm
Screw threadM3
Torque0.5 Nm ... 0.6 Nm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)3
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)3
DesignationEN 50156
Safety Integrity Level (SIL)3

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178, EN 60079-15
Rated insulation voltage250 V AC
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV from control circuit, start circuit, signal output to the enabling current path; 4 kV / basic insulation between all current paths and housing
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz ...150 Hz, 2g
ConformanceCE-compliant
UL, USA/CanadacULus
Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X
Class I, Div. 2, Groups A, B, C, D, T4
GLC, EMC2
Environmental simulation testISA-S71.04 (G3)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.