Product successfully added to your shopping cart
AXL F DI8/2 110/220DC 1F
2700684
PHOENIX_CONTACT
1
I/O module
I/O
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2700684 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 106 (C-6-2017) |
GTIN | 4046356916448 |
Weight per Piece (excluding packing) | 173.000 g |
Custom tariff number | 85389091 |
Country of origin | DE (Germany) |
Dimensional drawing | |
---|---|
Width | 53.6 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient temperature (operation) | -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail, input voltage: max. 264 V) |
---|---|
-25 °C ... 55 °C (Mounting position: any) | |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Designation | Axioline F connector |
---|---|
Connection method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Mounting type | DIN rail |
---|---|
Net weight | 173 g |
Note on weight specifications | with connectors and bus base module |
Degree of pollution | 2 |
Designation | Axioline F local bus |
---|---|
No. of channels | 2 |
Connection method | Bus base module |
Transmission speed | 100 Mbps |
Designation | Axioline F local bus supply (UBus) |
---|---|
Supply voltage | 5 V DC (via bus base module) |
Current consumption | max. 120 mA |
Power consumption | max. 600 mW |
Designation | Supply for digital input modules (UI) |
Protection | max. 8 A () |
Input name | Digital inputs |
---|---|
Description of the input | EN 61131-2 type 1 |
Connection method | Push-in connection |
Connection technology | 2-wire |
Number of inputs | 8 |
Type of protection | Polarity reversal protection of the inputs |
Input filter time | < 1 ms |
Input voltage | 110 V DC (Nominal voltage) |
220 V DC (Nominal voltage) | |
max. 300 V DC | |
Input voltage range "0" signal | -41 V DC ... 41 V DC |
Input voltage range "1" signal | 88 V DC ... 300 V DC |
Input voltage range | -300 V DC ... 300 V DC |
Nominal input current at UIN | 1.5 mA |
Test section | I/Os / logic 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201) |
---|---|
I/Os / logic 5 kV Pulse test voltage according to EN 61850/IEC 61850 | |
I/O / functional earth ground 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201) | |
I/O / functional earth ground 5 kV Pulse test voltage according to EN 61850/IEC 61850 | |
I/O / I/O (adjacent connectors) 2.5 kV Pulse test voltage according to EN 61850/IEC 61850 | |
Logic / functional earth ground 1 kV Pulse test voltage according to EN 61850/IEC 61850 |
Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
---|---|
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
Developed according to standard | IEC 61850-3 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A; 8 kV contact discharge; 8 kV air discharge |
IEC 61850-3 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, 20 V/m up to 1 GHz, 10 V/m up to 3 GHz | |
IEC 61850-3 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 4 kV | |
IEC 61850-3 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, ±2 kV (symmetrical), ±4 kV (asymmetrical) | |
IEC 61850-3 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V | |
IEC 61850-3 Immunity to magnetic fields, EN 61000-4-8/IEC 61000-4-8 300 A/m continuous, 1000 A/m for 1 s | |
IEC 61850-3 Immunity to attenuated oscillating magnetic fields, EN 61000-4-10/IEC 61000-4-10 100 A/m | |
IEC 61850-3 Immunity to conducted common-mode interference, EN 61000-4-16/IEC 61000-4-16 30 V continuous, 300 V for 1 s | |
IEC 61850-3 Attenuated oscillating waves, EN 61000-4-18/IEC 61000-4-18 1 kV symmetrical, 2.5 kV asymmetrical | |
IEC 61850-3 Radio interference properties EN 55022 Class B |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2700684-AXL F DI8/2 110/220DC 1F | 154 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.