AXL F AI4 I XC 1H 2702007 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F AI4 I XC 1H 2702007 PHOENIX CONTACT I/O module

AXL F AI4 I XC 1H

2702007

PHOENIX_CONTACT

I/O module

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $471.18
Unit price: $471.18

Quantity Price
1+$471.18
2+$459.70
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2702007
Packing unit1 pc
Catalog pagePage 114 (C-6-2017)
GTIN4046356900997
Weight per Piece (excluding packing)145.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight145 g
Note on weight specificationswith connectors and bus base module

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptiontyp. 120 mA
max. 150 mA
DesignationSupply for analog modules (UA)
Supply voltage24 V DC (I/O supply and sensor supply)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 45 mA (IiS= 0 mA)
typ. 118 mA (IiS= 4 x 20 mA (nominal load))
max. 125 mA (IiS= 4 x 20 mA (nominal load))
typ. 238 mA (IiS= 4 x 50 mA (full load))
max. 245 mA (IiS= 4 x 50 mA (full load))
Power consumptiontyp. 1.5 W (at UBusand UA)
max. 1.83 W (at UBusand UA)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Transient protection supply voltage

Analog inputs

Description of the inputDifferential inputs, current
Input nameAnalog inputs
Number of inputs4
Connection methodPush-in connection
Connection technology2, 3, 4-wire
Note regarding the connection technologyshielded
A/D conversion time31.25 µs
Resolution A/D16 bit
Limit frequency (3 dB)30 Hz
12 kHz
Type of protectionTransient protection of inputs
Overload protection of the current inputs
Data formatsIB IL, S7-compatible
Measured value representation16 bits (15 bits + sign bit)
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Input resistance current input104 Ω (typical)
Input filter30 Hz, 12 kHz and mean-value generation (can be parameterized)

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/analog inputs 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O)/analog inputs 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Analog inputs/functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.