AXL E PN IOL8 DI4 M12 6M 2701519 PHOENIX CONTACT Axioline E PROFINET device in a metal housing with 8 IO-Lin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL E PN IOL8 DI4 M12 6M 2701519 PHOENIX CONTACT Axioline E PROFINET device in a metal housing with 8 IO-Lin..

AXL E PN IOL8 DI4 M12 6M

2701519

PHOENIX_CONTACT

Axioline E PROFINET device in a metal housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Ethernet networks. Switches, routers, and antennas - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Dimensions

Width60 mm
Height185 mm
Depth38 mm
Note on dimensionsThe height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Drill hole spacing198.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 %
Permissible humidity (storage/transport)5 % ... 95 %
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP65/IP67

General

Net weight708.7 g
Mounting typeWall mounting or DIN rail mounting; both with mounting plate.

Interfaces

Fieldbus systemPROFINET
DesignationPROFINET
Connection methodM12 connectors, D-coded
Designation connection pointCopper cable
Transmission speed100 MBit/s (with auto negotiation)
Number of positions4

System limits of the bus coupler

DesignationPROFINET
Equipment typePROFINET Device
Conformance classB
Number of supported application relationships (AR)2
System-specific protocolsPROFINET protocols LLDP
PROFINET protocols MRP client
PROFINET protocols DCP
PROFINET protocols DCE-RPC
Protocols supportedSNMP v1
HTTP
TFTP
FTP

Power supply for module electronics

Module electronics and sensorsM12 connector (T-coded) Module electronics and sensors (US) 4
Connection methodM12 connector (T-coded)
DesignationModule electronics and sensors (US)
Number of positions4
Supply voltage24 V DC
Nominal supply voltage range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptionmax. 12 A
Typical current consumption180 mA ±15 % (at 24 V DC)
ActuatorsM12 connector (T-coded) Actuators (UA) 4
Connection methodM12 connector (T-coded)
DesignationActuators (UA)
Number of positions4
Supply voltage24 V DC
Nominal supply voltage range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptionmax. 12 A
Typical current consumption28 mA ±15 % (at 24 V DC)

Digital inputs

Input nameDigital inputs
Connection methodM12 connector, double occupancy
2, 3, 4-wire
Number of inputs4 (EN 61131-2 type 1)
Protective circuitProtection against polarity reversal
Input filter time< 1000 µs
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2701519-AXL E PN IOL8 DI4 M12 6M English 157 Kbytes PHOENIX CONTACT-2701519-AXL E PN IOL8 DI4 M12 6M

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.