C-UFB-24DC/E 2782313 PHOENIX CONTACT Attachment plug with surge voltage coarse and fine protection, for coax.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

C-UFB-24DC/E 2782313 PHOENIX CONTACT Attachment plug with surge voltage coarse and fine protection, for coax..

C-UFB-24DC/E

2782313

PHOENIX_CONTACT

10

Attachment plug with surge voltage coarse and fine protection, for coaxial signal interfaces with floating shield, signal voltage 24 V. Connection: BNC socket/plug

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Dimensions

Height93 mm
Width25.4 mm
Length25.4 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Degree of protectionIP20

General

Housing materialAluminum
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664-1
Mounting typeConnection-specific intermediate plugging
TypeAttachment plug
Direction of actionLine-Shield/Earth Ground

Protective circuit

IEC test classificationC2
C3
D1
Maximum continuous voltage UC30 V DC
Maximum continuous voltage UC(wire-shield)30 V DC
Nominal current IN185 mA (25 °C)
Operating effective current ICat UC≤ 10 µA
Residual current IPE≤ 2 µA
Nominal discharge current In(8/20) µs (Core-Earth)10 kA
Nominal discharge current In(8/20) µs (Core-Shield)10 kA
Total surge current (8/20) µs20 kA
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 500 V
Output voltage limitation at 1 kV/µs (Core-Shield) spike≤ 70 V
Output voltage limitation at 1 kV/µs (Core-Shield) static≤ 45 V
Residual voltage at In(conductor-ground)≤ 50 V (10 cm cable)
Residual voltage at In(conductor-shield)≤ 43 V
Voltage protection level Up(core-ground)≤ 500 V (C1 - 1 kV/500 A)
≤ 500 V (C3 - 10 A)
≤ 600 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(core-shield)≤ 70 V (C1 - 1 kV/500 A)
≤ 50 V (C3 - 10 A)
≤ 120 V (C2 - 10 kV / 5 kA)
Response time tA (Core-Earth)≤ 100 ns
Response time tA (Core-GND)≤ 500 ns
Input attenuation aE, asym.2 dB (≤ 20 MHz)
Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm systemtyp. 90 MHz
Impulse durability (conductor-ground)C2 - 10 kV/5 kA
D1 - 2,5 kA

Connection data

Connection methodBNC 50 Ω
Connection type INBNC socket
Connection type OUTBNC plug

Connection, equipotential bonding

Connection methodPVC litz wire

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.